background image

V1.0_0212 |   Division of Davcor Group Pty Ltd     |     www.smartlock.com.au     |     www.smartlock.co.nz

1.  Enter Master combination (00 555555) and hold down last digit 

of combination until unit double signals and the LED stays on.

2.  PRESS 8.

3.  Enter operational mode: (0-7 - corresponding operational 

mode from chart below.)

4.  Re-enter operational mode (0 – 7) to confirm.

1.  Enter Manager combination and 

hold down last digit of 

combination until unit double signals and the LED stays on.

2.  PRESS 2. Unit signals twice.

3.  Enter User ID (02 to 31). User is temporarily disabled. (User 

combination is saved and will be valid if reinstated.)

1.  Enter Manager combination and hold down last digit of 

combination until unit double signals and the LED stays on.

2.  PRESS 3. Unit signals twice.

3.  Enter User ID (02 to 31). User is deleted.

1.  Enter Manager combination and 

hold down last digit of 

combination until unit double signals and the LED stays on.

2.  PRESS 1. Unit signals twice.

3.  Enter User ID (02 -31). Unit signals once. User is reinstated. (If 

deleted continue with steps 4-6.)

4.  Enter User ID and new combination XXXXXX.  

(Example: 02 222222.)

5.  Re-enter ID XXXXXX.

6.  The Lock will double signal if the operation was successful, 

and triple signal if not accepted.

1.  1. Enter User ID (00-31) and current combination (example 02 

222222) and 

hold down last digit of combination until unit 

double signals and the LED stays on.

2.  PRESS 0 (change combination).

3.  Enter User ID and new combination XXXXXX.  

(Example 02 020202.)

4.  Reenter User ID and new combination XXXXX (to confirm).

5.  The Lock will double signal if the operation was successful, 

and triple signal if not accepted.

1.  1. Enter Manager combination and hold down last digit of 

combination until unit double signals and the LED stays on.

2.  PRESS 9. Unit signals twice.

3.  Enter two-digit Delay period value (00 to 99 minutes) followed 

by the two-digit Open period value (00 to 19 minutes). 

• Unit will signal twice, if accepted. 

• Unit will signal three times, if invalid.

4.  Re-enter the Delay and Open period values, to confirm. 

• Unit will signal twice and feature is active.

Example: TD override and Silent Alarm

Key press sequence – 00 55555 (hold last) 8, 5, 5

(operation complete). 

It is recommended that the Master combination be changed from

the default combination.

1.  Enter Master combination (00 555555) and hold down last digit 

of combination until unit double signals and the LED stays on.

2.  PRESS 0 (change combination).

3.  Enter 00 and new combination XXXXXX. (Example 00 654321.)

4.  Reenter 00 and new combination XXXXX (to confirm).

5.  Lock is now in operational mode, and the only function the 

Master can now perform is resetting the lock.

The Master combination must be changed from the initial

combination used during activation in order to enable all the

Manager functions.

1.  Enter Manager combination (01 XXXXXX) and 

hold down last 

digit of combination until unit double signals and the LED 

stays on.

2.  PRESS 0 (change combination).

3.  Enter 01 and new combination XXXXXX. (Example 01 111111.)

4.  Reenter 01 and new combination XXXXX (to confirm).

5.  Lock is now in operational mode, and the only function the 

Master can now perform is resetting the lock.

66E

Supra v1.10

To enroll/activate the Manager (Master only)

Exiting Setup Mode

Changing the Master Combination:

Changing the Master Combination:

Mode Option Time Delay Override 

(User 31)

Dual Mode Silent Alarm

0

1

x

2

x

3

x

x

4

x

5

x

x

6

x

x

7

x

x

x

NOTE: While the lock is in Setup Mode, only the Master can

perform “Manager Functions” (see Operational Instructions).

Once in Operational Mode, only the Master User can perform

these functions.

NOTE: Entering 0000 will deactivate the Time Delay Feature.

NOTE: If Time Delay is active it may only be deactivated or delay 

value decreased in Open Period.

CAUTION: Always perform this operation with the door open, and

test the opening of the Lock with the new combination several

times before closing the door.

WARNING: Once the Master or the Manager changes their

combination then the setup is frozen (Operational Mode). Lock

must be reset either with Master reset or Reset box (p/n 6066) to

change configuration or add Users.

This Function will reset the Lock to pre-setup mode; all Lock settings 

and Users are erased. To perform a Master Reset the following two 

condition must be met: The Lock must be in Operational Mode 

AND the Manager combination must be changed from the initial 

combination used to enroll/activate the Manager.

1.  Enter Master combination and 

hold down last digit of 

combination until unit double signals and the LED stays on.

2.  PRESS 8 (Special Function - Master Reset).

3.  Enter Manager combination.

4.  Lock will sound one long beep (approx. 2 seconds); the lock is 

now in pre-setup mode.

5.  PRESS 1 to open the lock. 

Example: 00 654321 (hold last); 8, 01 111111 (operation complete)

Master Reset:

OPERATIONAL INSTRUCTIONS
MANAGER FUNCTIONS

Disable User

Delete User

Reinstate User

Change Combination (all users)

Set/Change Time Delay Values

Отзывы: