background image

005/ 015 / 050 / 150 / 500 / 1000

DAV TECH SRL

Via Ravizza, 30 - 36075 Montecchio Maggiore (VI) - ITALY

Tel. 0039 0444 574510 - Fax 0039 0444 574324

[email protected] - www.davtech.it

VOLUMETRIC PUMPS PCP

Installation and 

maintenance guide

Содержание PCP 005

Страница 1: ...0 150 500 1000 DAV TECH SRL Via Ravizza 30 36075 Montecchio Maggiore VI ITALY Tel 0039 0444 574510 Fax 0039 0444 574324 davtech davtech it www davtech it VOLUMETRIC PUMPS PCP Installation and maintena...

Страница 2: ...composition 3 2 Notes before use 3 3 Connection A stator B rotor 3 4 Eliminating bubbles before dispensing the fluid 4 TYPICAL SETUP pag 6 5 PUMP MAINTENANCE pag 8 6 TROUBLESHOOTING pag 10 7 SYSTEM P...

Страница 3: ...st accuracy without be affected from inlet fluid pressure viscosity and temperature of the media etc The motor drived in one direction dispense the fluid and if drived in the other direction suck back...

Страница 4: ...r contamination Replace consumable materials such as syringes and nozzles at every use and clean contaminated parts such as rotor and stator The digital transducer of the air pressure regulator gives...

Страница 5: ...a short duration of time there might be a damage on the stator When eliminating air bubbles set the motor speed at low 5 10RPM to discharge Eliminating air bubbles 3 3 Connection A stator and B rotor...

Страница 6: ...er use 4 3 Follower plate pump and Controller use Air hose Air hose Pump motor cable PCP pump fluid supply hose fluid supply hose Controller Controller Controller Cartridges holder Syringe Pressure re...

Страница 7: ...ir hose Pump motor cable PCP pump fluid supply hose fluid supply hose Driver Modbus o Profinet Cartridges holder Syringe Pressure regulator Pressure regulator max 5 bar Pump motor cable Pump motor cab...

Страница 8: ...e instructions below to perform maintenance of the pumps A Prepare the pump and the necessary tools B Turn the screws nr 1 and unplug it to separate the elements 2 and 3 then unscrew the screws n 4 if...

Страница 9: ...Turn the element nr 6 counter clockwise to separate the element nr 7 Using the fixed tool supplied nr 8 in the motor joint rotate and separate the stator nr 9 E Unscrew nr 10 screw M3x35 to separate...

Страница 10: ...4 Verify that at rest the motor does not continue to turn 5 Verify that the pressure of the incoming fluid does not exceed from the one shown in the datasheet The pump motor does not run 1 Check the c...

Страница 11: ...UCTURE Failure to maintain or use the pump in conditions that do not correspond to those indicated in this manual may result in total damage to the pump itself DAV Tech is pleased to support customers...

Страница 12: ...Installation and maintenance guide 8 BREAKDOWNS 8 1 Breakdown PCP 005 1 2 3 4 5 6 8 9 10 20 16 18 18 19 15 14 21 12 11 13 17 7 Dedicated to pump model body Pump PCPM extension...

Страница 13: ...NLET MODULE SMALL BODY PCP SX 7 SMALL INLET ADAPTER PCP 7 1 PCPM SYRINGE10CC INLET ADAPTER PCP SYRINGE 10CC 7 2 PCPM SYRINGE3055CC S SMALL INLET ADAPTER PCP SYRINGE 30CC 7 3 PCPM 310 S SMALL INLET ADA...

Страница 14: ...Installation and maintenance guide 8 2 Breakdown PCP 015 1 2 3 4 5 6 8 9 10 16 18 18 19 15 14 21 12 11 13 Dedicated to pump model body Pump PCPM extension 7 20 17...

Страница 15: ...K PEEK THREADED SMALL BODY PCP SX 6 3 PCPM BODY S INLET MODULE SMALL BODY PCP SX 7 SMALL INLET ADAPTER PCPM 7 1 PCPM SYRINGE10CC INLET ADAPTER PCP SYRINGE 10CC 7 2 PCPM SYRINGE3055CC S SMALL INLET ADA...

Страница 16: ...Installation and maintenance guide 8 3 Breakdown PCP 050 1 2 3 4 5 6 8 9 10 16 18 18 19 15 14 21 12 11 13 Dedicated to pump model body Pump PCPM extension 7 17 20...

Страница 17: ...PEEK THREADED SMALL BODY PCP SX 6 3 PCPM BODY S INLET MODULE SMALL BODY PCP SX 7 SMALL INLET ADAPTER PCP 7 1 PCPM SYRINGE10CC INLET ADAPTER PCP SYRINGE 10CC 7 2 PCPM SYRINGE3055CC S SMALL INLET ADAPT...

Страница 18: ...Installation and maintenance guide 8 4 Breakdown PCP 150 1 2 3 4 5 8 9 10 16 18 18 19 15 14 20 12 11 13 7 Dedicated to pump model body Pump PCPM extension 15 6 17...

Страница 19: ...LET MODULE BIG BODY PCP SX 6 BIG INLET ADAPTER PCP 6 1 PCPM SYRINGE3055CC B BIG INLET ADAPTER PCP SYRINGE 30CC 6 2 PCPM 310 B BIG INLET ADAPTER PCP CARTRIDGE 310CC 6 3 PCPM SEMCO B BIG INLET ADAPTER P...

Страница 20: ...8 5 Breakdown PCP 500 Installation and maintenance guide 1 2 3 4 5 8 9 10 16 18 18 19 15 14 20 12 11 13 7 15 Dedicated to pump model body Pump PCPM extension 6 17...

Страница 21: ...LE BIG BODY PCP SX 6 BIG INLET ADAPTER PCPM 6 1 PCPM SYRINGE3055CC B BIG INLET ADAPTER PCP SYRINGE 30CC 6 2 PCPM 310 B BIG INLET ADAPTER PCP CARTRIDGE 310CC 6 3 PCPM SEMCO B BIG INLET ADAPTER PCP SEMC...

Страница 22: ...8 6 Breakdown PCP 1000 Installation and maintenance guide 1 2 3 4 5 8 9 10 16 18 18 19 15 14 14 21 12 11 13 7 20 Dedicated to pump model body Pump PCPM extension 6 17...

Страница 23: ...ULE BIG BODY PCP SX 6 BIG INLET ADAPTER PCP 6 1 PCPM SYRINGE3055CC B BIG INLET ADAPTER PCP SYRINGE 30CC 6 2 PCPM 310 B BIG INLET ADAPTER PCP CARTRIDGE 310CC 6 3 PCPM SEMCO B BIG INLET ADAPTER PCP SEMC...

Страница 24: ...Code Photo PRESSURE SENSOR PCP PDP PCP PRESSURESENSOR MOTR CABLE PCP 2 MT CABLEPCP 2MT MOTR CABLE PCP 7 MT CABLEPCP 7MT MOTR CABLE PCP 10 MT CABLEPCP 10MT CONTROLLER BASIC CONTROLLER FOR PCP CONTROLL...