We reserve the right to modify at any time, without notice, the specifications, dimensions and weights in this datasheet. The illustrations are not binding.
NOZZLES FOR DA 400 DISPENSING VALVE
The valve DA 400 presents a very high number of nozzles available as
standard. Nozzles with thread 1/8 BSP male, luer lock, nozzles complete
with various shapes and diameters from 0.3 to 1.5 mm. If necessary, we
can design and create multi-point terminals, with radial outlets, inclined etc.
DRIVE THE VALVE DA 400
The valve DA 400 have to be drived by solenoid 5/2 or 3/2 (depending on whether you want to work double-acting
or simple acting) for a time setted by the PLC of the customer. We are available for the supply of timing systems
such as the DA 1000 T controller or even with the creation of electrical control panels to manage the various I / O
you need to check.
Connection diagram
• 0.3
• 0.5
• 0.8
• 1
• 1.5
LV
18
SY
MG
• 0.3
• 0.5
• 0.8
• 1
• 1.5
KV
• 0.3
• 0.5
• 0.8
• 1
• 1.5
KL
Valve configurations
DA 400_ _ _ _
Ø
Ø
Ø
NOZZLES AVAILABLE
REGULATION
screw
micrometric
RM
NR
S.V. 5/2
ALSO POSSIBLE
SIMPLE
ACTING
PNEUMATIC PUMP
PLC
PRESSURE
STABILIZATOR
Special versions available on request.
mm
mm
mm
2.3 Connection diagram
3 INSTALLATION
3.1 Mounting on the machine
The valve 400 can be mounted using the through holes present on its body. Download 3D models of the valve from our
web-site to design brackets, fasteners, and check the dimensions.
3.2 Drive the valve
The valve 400 can be used as a single-acting valve, air for opening and closing with the spring; or as a double-effect
valve, air for opening and closing. The valve 400 must be connected to a solenoid valve 3/2 for the opening or to a
solenoid valve 5/2 for opening and closing. The minimum operating pressure must be at least 6 bar.
Air inlet