SNMPv2 manager using the Party3/Party4 pair.
MD5(1):
The Party3/Party4 MD5 secret key is a 32 character ASCII representation of a 16 byte
hex value. The allowed characters are 0-F and the space character. Any space characters will be
converted to an ASCII 0 in the string.
Party6 TAddress:
The Party6 TAddress is the IP address (in dotted decimal format) of the
SNMPv2 manager using the Party5/Party6 pair.
MD5(2):
The Party5/Party6 MD5 secret key is a 32 character ASCII representation of a 16 byte
hex value. The allowed characters are 0-F and the space character. Any space characters will be
converted to an ASCII 0 in the string.
Party8 TAddress:
The Party8 TAddress is the IP address (in dotted decimal format) of the
SNMPv2 manager using the Party7/Party8 pair.
MD5(3):
The Party7/Party8 MD5 secret key is a 32 character ASCII representation of a 16 byte
hex value. The allowed characters are 0-F and the space character. Any space characters will be
converted to an ASCII 0 in the string.
NTP Authentication:
Enables or disables the use of NTP Authentication per RFC-1305.
NTP Authentication ONLY:
Enables or disables the NTP Authentication ONLY mode which
restricts access to the TYMSERVE.
NTP Authentication Key ID:
The Key ID identifies the NTP Authentication key currently in
use on the TYMSERVE.
NTP Authentication Key:
The Authentication Key is a MD5 secret key used for NTP
Authentication. It is programmed as an 8 character ASCII value.
4.8 TIMING PARAMETER DESCRIPTION (-GPS, -IRIG)
This section describes the TIMING parameters for the -GPS and -IRIG versions.
Timing Source:
This parameter sets the timing source for the TYMSERVE. When using time
code, be sure to select the time code format, and connect the time code source to the rear panel
(see Chapter 5). When using the internal clock, you must set the time manually from the
FEATURE area. When using the external 1 PPS source, you must set the time manually, and
connect the external 1 PPS to the rear panel. To use the GPS source you must have the -GPS
option which consists of a GPS antenna and cable.
Time Code Format:
Selects one of several time code formats. Also selects between modulated
and DCLS (DC Level Shift) forms of time code.
Current Year:
For all timing sources except GPS you must tell the TYMSERVE what year it is
because this information is not present with any timing source except GPS.
TYMSERVE 2000 Manual
Datum Inc, Bancomm Div.
xxiv
Содержание TYMSERVE 2000
Страница 1: ...TYMSERVE 2000 NETWORK TIME SERVER Operation and Technical Manual ...
Страница 2: ...TYMSERVE 2000 NETWORK TIME SERVER Operation and Technical Manual OCTOBER 1995 ...
Страница 13: ...This Page Intentionally Left Blank Datum Inc Bancomm Div TYMSERVE 2000 Manual xiii ...
Страница 20: ......
Страница 39: ...San Jose CA 95119 1294 US Tel 1 408 578 4161 Fax 1 408 578 4165 ...
Страница 54: ...TABLE OF CONTENTS TYMSERVE 2000 Manual Datum Inc Bancomm Div liv ...