background image

8

CROSSLINE LASER LEVEL

CALIBRATION CHECK

It’s possible for you to check the calibration of the laser. Calibration by yourself is only 

approximate and the accuracy of the calibration will depend on the care with which you 

proceed.

TO CHECK THE LEVEL

Checking the horizontal pitch calibration of the laser requires 2 walls, which must be at least 5 

metres apart. The best calibration results can be achieved if the laser is mounted on a tripod.

1.  Mark point A1 on the wall.
2.  Turn the device 180 ° and mark A2 on the opposite side of A1. You now have a horizontal 

reference between point A1 and A2.

 

3.  Position the device as near as possible to the wall at the same height of point A1.
4.  Turn the device 180° and mark point A3. The difference between point A2 and A3 is the 

tolerance. 

1. 
1. 

 

If the distance between A2 and A3 is more than 2mm/10m, the device is in need of calibration. 

Contact authorised dealer or service agent. 

CHECKING THE VERTICAL LINE

1.  Position the device about 5 m from a wall. Fix a plumb bob with a line of 2.5 m length on 

the wall, making sure that the bob can swing freely. 

2.  Switch on the device and align the vertical laser to the plumb line. The precision is within 

the specified tolerance if the deviation between the laser line and the plumb line is not 

greater than ± 2 mm.

Содержание DT3X360G

Страница 1: ...3 X 360 LASER LEVEL MODEL NO DT3X360R DT3X360G OPERATING INSTRUCTIONS TOPREVENT SERIOUS INJURY READ AND UNDERSTAND ALLWARNINGS AND INSTRUCTIONS BEFORE USE ...

Страница 2: ...NS 3 HAZARD SIGNAL WORD DEFINITIONS 3 GENERAL SAFETY RULES FOR OPERATION 4 COMPONENT IDENTIFICATION 5 OPERATION INSTRUCTION 6 OPTIONAL ACCESSORIES 7 CALIBRATION CHECK 8 MAINTENANCE AND SERVICE 9 TROUBLESHOOTING 10 PRODUCT LABELS 10 WARRANTY INFORMATION 12 ...

Страница 3: ...READS 1 4 and 5 8 1 4 and 5 8 DETECTOR Optional Part No DT01REC sold seperately DATUM is constantly improving its products All information in this manual is based on the latest product information available at the time of printing The specifications outlined herein are subject to change without prior notice or obligation The purchaser and or user shall assume liability for any modification and or ...

Страница 4: ... set up to avoid accidental movement Always ensure the laser beam is aimed at a sturdy work piece without reflective surface Bright shiny reflective sheet steel or the like is not suitable for laser use as the reflective surface could direct the beam back at the operator Do not break up or throw the battery into fire please recycle the battery after use Turn the laser off when it is not in use Lea...

Страница 5: ... Vertical laser output window v2 6 1 4 Tripod thread 7 5 8 Tripod thread 8 Battery compartment 9 Wall bracket DT06AC 2 1 3 4 6 7 8 9 10 11 5 13 12 10 Height adjustment knob 11 Clamp 12 1 4 Thread thumb screw 13 1 4 And 5 8 tripod threads 14 Laser glasses 15 Laser target 16 Battery charger 17 AA battery carrier 18 Li ion battery charging holder 18 17 16 14 15 ...

Страница 6: ...store with pendulum lock on or power switch to OFF position and in its protective case Press and hold LINE button to switch on the laser Alternatively turn the laser on by sliding the Power Switch Pendulum Switch to ON UNLOCK position Pendulum is automatically released for self levelling To turn the laser off place it on a stable flat surface Slide the Power Switch Pendulum Switch to OFF LOCK posi...

Страница 7: ...will be on when this is activated Press the button again to exit pulse mode OPTIONAL ACCESSORIES DATUM offers a range of accessories that are compatible with our laser levels They can be purchased seperately and add more flexibility to get your job done HYBRID LINE LASER DETECTOR DT01REC LINE LASER TRIPOD DT1450C FLAT HEAD LASER TRIPOD DT1730F Maximum height 1450mm Minimum Height 610mm Maximum hei...

Страница 8: ...ve a horizontal reference between point A1 and A2 3 Position the device as near as possible to the wall at the same height of point A1 4 Turn the device 180 and mark point A3 The difference between point A2 and A3 is the tolerance 1 1 If the distance between A2 and A3 is more than 2mm 10m the device is in need of calibration Contact authorised dealer or service agent CHECKING THE VERTICAL LINE 1 P...

Страница 9: ... when the device is not in use Keep the laser level clean at all times Use a soft lint free cloth for the body and lens tissue for glass windows Do not use abrasive cleaners or solvents Don t expose the laser level to high temperatures or humidity Do not store the laser level in the hot areas hot temperatures can short the life of electronic device damage battery and warp or melt certain plastics ...

Страница 10: ...CT ACCORDING TO IEC EN 60825 1 2014 Country of Origin Check Codes Text Panel Direct Warranty Spellcheck Check shadows Die Overprints Delete extra art Resolution Spec Swatches Supplier Contact Add Dimensions Colours Seps Bleed Colours Filename 135042 DAT 3 x 360 Multi Line Laser Level Red DT3X360R v Date 02 07 2019 Dieline Pantone 166 C ption 3 X 360 MULTI LINE LASER LEVEL RED BEAM DT3X360R Barcode...

Страница 11: ...11 OPERATING MANUAL ...

Страница 12: ... product Consumer guarantees Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a m...

Отзывы: