OPERATING MANUAL

CALIBRATION CHECK

It’s possible for you to check the calibration of the laser. Calibration by yourself is only 

approximate and the accuracy of the calibration will depend on the care with which  

you proceed.

TO CHECK THE LEVEL

Checking the horizontal pitch calibration of the laser requires 2 walls, which must be at least  

5 metres apart. The best calibration results can be achieved if the laser is mounted on a tripod.

1.  Mark point A1 on the wall.
2.  Turn the device 180 ° and mark A2 on the opposite side of A1. You now have a horizontal 

reference between point A1 and A2.

 

3.  Position the device as near as possible to the wall at the same height of point A1.
4.  Turn the device 180° and mark point A3. The difference between point A2 and A3 is the 

tolerance. 

1. 
1. 

 

If the distance between A2 and A3 is more than 2mm/10m, the device is in need of calibration. 

Contact authorised dealer or service agent. 

Содержание DT1H1V2PR

Страница 1: ...CROSSLINE LASER LEVEL WITH PLUMB DOTS MODEL NO DT1H1V2PR DT1H1V2PG OPERATING INSTRUCTIONS TOPREVENT SERIOUS INJURY READ AND UNDERSTAND ALLWARNINGS AND INSTRUCTIONS BEFORE USE...

Страница 2: ...PECIFICATIONS 3 HAZARD SIGNAL WORD DEFINITIONS 3 GENERAL SAFETY RULES FOR OPERATION 4 COMPONENT IDENTIFICATION 5 OPERATION INSTRUCTION 6 CALIBRATION CHECK 7 MAINTENANCE AND SERVICE 9 TROUBLESHOOTING 9...

Страница 3: ...al Part No DT01REC sold seperately DATUM is constantly improving its products All information in this manual is based on the latest product information available at the time of printing The specificat...

Страница 4: ...eyes Set up cross line laser to ensure laser beam path is above or below eye level Ensure cross line laser is securely set up to avoid accidental movement Always ensure the laser beam is aimed at a st...

Страница 5: ...indow 4 Up plumb dot output window 5 Horizontal laser output window 6 1 4 Tripod thread 7 Down plumb dot output window 8 Battery compartment 9 Wall bracket 10 Magnets on b 11 Height adjustment knob 12...

Страница 6: ...witch is turned to OFF position LASER LINES SELECTION Turn the switch to ON position All lines appear when the laser is turned on Press LINE button to select laser lines AUTOMATIC SELF LEVELLING Pendu...

Страница 7: ...t The best calibration results can be achieved if the laser is mounted on a tripod 1 Mark point A1 on the wall 2 Turn the device 180 and mark A2 on the opposite side of A1 You now have a horizontal re...

Страница 8: ...al laser to the plumb line The precision is within the specified tolerance if the deviation between the laser line and the plumb line is not greater than 2mm CHECKING THE HORIZONTAL LINE 1 Position th...

Страница 9: ...temperature moisture can form inside where it may damage circuit board Avoid shock vibrations and extreme heat Do not immerse the instrument in water Always slide the power switch to the OFF position...

Страница 10: ...with Plum Dots Red DT1H1V2PR Date 02 07 2019 Nicole Jim Dieline Pantone 166 C Brand DATUM Description CROSS LINE LASER LEVEL WITH PLUMB DOTS RED BEAM Pronto 135040 Part DT1H1V2PR Barcode 932822504927...

Страница 11: ...11 OPERATING MANUAL...

Страница 12: ...product Consumer guarantees Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensatio...

Отзывы: