PSM-500/500L/500LT SCPC Satellite Modem
Operation
PSM-500/500L/500LT - Rev. 0.91
Page 3-15
Unit Parameter Detail
Representation
Type
Entry
Description
Alarm Reference
To Alarm A
Selection
0=None, 1=A, 2=B, 3=A&B,
4 = Mute CXR,
5 = Mute & Alarm A,
6 = Mute & Alarm B,
7 = Mute & Alarm A & B
Selects destination and
action taken for reference
oscillator alarm types.
Alarm OCXO Oven
Mute & Alarm A
Selection
0=None, 1=A, 2=B, 3=A&B,
4 = Mute CXR,
5 = Mute & Alarm A,
6 = Mute & Alarm B,
7 = Mute & Alarm A & B
Selects destination of alarm
Alarm Tst Active
To Alarm A
Selection
0=None, 1=A, 2=B, 3=A & B
Selects destination of alarm
Alarm Hardware
To Alarm A
Selection
0=None, 1=A, 2=B, 3=A & B
Selects destination of alarm
Alarm Beep
On Alarm A & B
Selection
0=None,
1=On Alarm A,
2=On Alarm B,
3=On Alarm A & B
Selects if alarm causes a
unit audible “beep”.
Test Modem
Disabled
Selection
0 = Disabled,
1 = Lamp Test,
2 = Self Test
3 = Lamp & Self Test
Carrier output mode for test
purposes.
Test Cal Ref
Disabled
Selection
0 = Disabled,
1 = Enabled
Calibrates the internal
reference to an external
input.
Test Update ROM
Disabled
Numeric
Normally Disabled,
Enter unit serial number and
“Enter” key to start.
Entering the serial number
and pressing “Enter” starts
the update process.
Test Ref AFC
+1.1V
Read Only
N/A
Internal Loop Voltage
Test SysClk AFC
+9.1V
Read Only
N/A
Internal Loop Voltage
Test +3.3V
+3.3V
Read Only
N/A
Internal Supply Voltage
Test +5.0V
+5.0V
Read Only
N/A
Internal Supply Voltage
Test +12.0V
+12.1V
Read Only
N/A
Internal Supply Voltage
Test +21.0V
+20.8
Read Only
N/A
Internal Supply Voltage
Test -12.0V
-12.1V
Read Only
N/A
Internal Supply Voltage
Test Boot Code
0000:0000:0000
Read Only
N/A
Factory Diagnostic Use