background image

Содержание ABB1000

Страница 1: ...NNA TECHNICAL MANUAL Datron World Communications Inc Manual Ref ABB1000 MS Publication Date December 2002 Revision C JI_I 3030 Enterprise Court Vista CA 92083 USA Phone 760 597 1500 Fax 760 597 1510 E...

Страница 2: ......

Страница 3: ...e that a remedy has been implemented If the user fails to perform the agreement will be terminated by further written notice from Datron Upon termination the user shall immedi ately return all origina...

Страница 4: ...ment 3 Date of installation Parts returned without this information will not be replaced In the event of a dispute over the age of the replacement part components date coded over 24 months previously...

Страница 5: ...gures ABBlOOO Antenna Components 1 2 ABBI000B Configuration 1 4 ABB lOOOAConfiguration 1 4 Diamond Antenna Configuarion for Model ABB lOOOA 1 5 Rectangle Antenna Configuration for Model ABB lOOOA 1 5...

Страница 6: ...iv This page intentionally left blank...

Страница 7: ...m RG213 coaxial cable and PL 259 UHF connector Extended length model for increased effi ciency in the 2 to 10 MHz range antenna length is 43 3m ABB 1000B Broadband antenna 2 to 30 MHz 1000W supplied w...

Страница 8: ...transformer 2 37m stainless steel wire with hooks and lugs 1 Terminating network mounted on large heat sink 2 7 6m nylon guy line 4 Cable hooks 1 Sm RG 213 coax cable with transformer 2 Insulators Se...

Страница 9: ...nications Figure 4 shows the ABBIOOOA model in a diamond configuration and Figure 5 shows the same model in a rectangle configuration Two additional insulators are included to aid in the construction...

Страница 10: ...tion Insulator 9 1m on two sides To transceiver antenna port Figure 2 ABB1000B Configuration 12 2m 3m J_ 44m Termination 12 2m Insulator on two sides 1 I 1 4 To transceiver antenna port Figure 3 ABB 1...

Страница 11: ...ination 13 7m Insulator Guy wire 15 5m Figure 4 Diamond Antenna Configuarion for Model ABB1000A UV Resistant Nyl9n support wire Insulator Dn fDur cDmers 15 5m 33m Termination ABB 1OOO MSc To transceiv...

Страница 12: ...he end of the stainless steel cable to the eyebolts on the side of the transformer Install the solder lug onto the 10 bolts located on each side of the transformer Tighten the nuts securely See Figure...

Страница 13: ...greater than 15m The bottom stainless steel wire should be a minimum of 3m above the ground or roof of the building 10 Connect the long coax to your communications system antenna output Your system is...

Страница 14: ...Cable hook Solder Lug Figure 7 Attaching Cable to Transformer Transformer Eyebolt It Figure 8 Attaching Cable to Terminating Network 8 ABB1000 MSc...

Страница 15: ...d to attach the coax to the balun inside the transformer assembly 2 Cut the coax off at the end of the lead in wires cutting off as lit tle of the lead in wires as possible 3 Prepare and reattach the...

Страница 16: ...10 This page intentionally left blank ASS 1OOO MSc...

Отзывы: