Dateq DDA-2300 Скачать руководство пользователя страница 6

6

AMPLIFIER OPERATION GUIDANCE 

Setup

 

Before operating the DDA-x300 series amplifier, check the mains supply voltage and connect the IEC inlet to the 
mains power supply using the power lead supplied (or equivalent). Ensure that the cooling vents at front and rear are 
not covered or obstructed in any way with adequate space for air-flow through the unit. 

Each side of the DDA-4300 series amplifier can be operated as an independent pair of channels or as a single com-
bined output in Bridge mode. Set the mode using the selector switch for the relevant pair of channels (rear panel 7). 

Bridge mode offers the option of operating the DDA-4300 as a stereo amplifier into 2 larger 8  speakers. It is also 

Ω

possible to operate one side in Bridge mode to create 1 high output channel with the other side in stereo, which can 
be useful to power a large sub and a pair of satellite speakers (left + right). 

Stereo mode

 

Connect Left and Right speakers to Channel 1 and Channel 2 outputs via the SPK (rear panel 2, 3) . For SPK wiring, 
c and - wires to pins 1+ and 1-. Ensure that the combined load on each channel is no lower than 40 (for 
speakers in parallel, 8  + 8  = 4 ) Connect line level Left and Right inputs to the CH 1 and CH 2 XLR inputs ( rear 

Ω

Ω

Ω

panel 6, 8) 

Parallel mode

 

Connect the speakers to the speaker outputs as described above but both outputs will only receive a mono signal from 
the CH 1 XLR input ( rear panel 8) and is controlled by CH1 volume control ( front panel 1) 

Bridge mode

 

Bridge mode is different to the other 2 modes in that it combines both output channels to a single mono output. This 
mode enables double the power to a single speaker output compared with Stereo or Parallel modes. The difference is 
that the speaker load must be no lower than 8 , whether a single speaker or combined load. Bridge mode can be 

Ω

useful especially when driving a large, high power subwoofer. Connect speaker(s) to the Channel 1 SPK output. 
Connect the "+" speaker wire to amplifier 1+ (rear panel 3) and the "—" speaker wire to amplifier 2+ (rear panel 3). 
Incorrect speaker wiring can damage the amplifier! Bridge output receives a mono signal from CH 1 XLR input (rear 
panel 8) and is controlled by CH 1 volume control (front panel 1) 

Operation

 

With channel gain controls (front panel 1, 5) turned fully down (anti-clockwise), switch on the power (front panel 6) and 
the LED POWER indicator will light. Playing the input signal into the connected channel inputs, gradually increase the 
relevant gain controls (only CH 1 will have an effect in Bridge mode). The amplified signal should be heard through the 
speakers and the SIG indicators (front panel 2, 4) should respond to the audio output. Increase the volume controls to 
the required level. Alongside the SIG indicators are CLIP indicators, which should only light very briefly on the loudest 
transients or spikes in the audio. If the CLIP LEDs light for more than a fraction of a second at a time, the volume 
controls should be turned down or input signal will need to be reduced. 

Before powering down, turn down the volume controls to avoid loud pops or noises through the speaker. 

Содержание DDA-2300

Страница 1: ...DDA 2300 DDA 4300 Class D Power Amplifier ...

Страница 2: ...mplifiers that produce devices he t a 9 WARNI To reduce the risk of fire or electric sho o not expose this apparatus to rain or NG ck d moisture 10 Connect the device to a mains outlet with a protective ar connection e th Important nformation Safety I WARNING TO PR G EVENT FIRE OR SHOCK HAZARD DO NOT USE THE PLU WITH AN N ION CORD RECEPTACLE OR OTHER OUTLET UNLESS THE DES EXTE S BLA CAN BE FULLY INS...

Страница 3: ...s stereo parallel Ω 500W 4Ω per ch and bridge for flexible usage With protection including clip high temp overload and short circuit to ensure this amplifier works properly under any working environment Features Switching power technology Class D power amplifier Green technology amplifier of 85 efficiency With PWM special power circuit to ensure excellent cooling system 19 universal rack mount type in 1...

Страница 4: ...4 ...

Страница 5: ...5 ...

Страница 6: ...ntrol front panel 1 Bridge mode Bridge mode is different to the other 2 modes in that it combines both output channels to a single mono output This mode enables double the power to a single speaker output compared with Stereo or Parallel modes The difference is that the speaker load must be no lower than 8 whether a single speaker or combined load Bridge mode can be Ω useful especially when driving ...

Страница 7: ...7 DDA 2300 DDA 4300 ...

Страница 8: ...8 ...

Отзывы: