Fields
<Left>
and
<Right>:
They set the coordinates of the left and the right side of
the frame in dots. Possible values are between - 607 to 607.
Fields
<Top>
and
<Bottom>:
They set the coordinates of the upper and the lower side
of the frame in dots. Possible values are between - 1639 to 1639.
Field
<Thickness>:
Sets the thickness of the frame in dots. The thickness is at the
expense of the interior area of the frame and possible values are between 1 and 80.
3.10. Inserting graphics
Offers the option to include a graphical image into the label. The image must be pro-
cessed into the monochrome PCX format
Fields
< Start> and <Start Y>:
Set the coordinates of the upper left angle of the
image. These coordinates may be entered directly although positioning the image with
the mouse is much easier.
Field
<Store as>:
Enters a name under which the graphic image will be stored in the
memory.
Field
<Load>:
Opens a dialog window for selecting a PCX file. When inserting a new
image this operation is obligatory.
3.11. Defining variables and counters
Defines and sets the form of the counters and variables used in the label. You can define
not more than 32 variables and up to 8 counters.