background image

Datecs    

                                                                                                                            USERS MANUAL 

                                                                                                                                                                   21.06.2011 

 

KEYBOARD 

 

 

 

 

 

 
 

UNPACKING 

 

 

After you take out the ECR from its carton box and remove the pickings and the plastic cover, you will find 

this manual and the device passport. 
 

 

IMPORTANT INSTRUCTIONS: 
1. DO NOT install the device under direct sunlight or near heating apparatus! 
2. DO NOT install the device in locations that have steam, humidity and dust! 
3. DO NOT use a mains connection in sockets shared by other power consumers (for example   
    refrigerators, motors, etc.)  
4. Put the ECR on a place which able suitable work and which able both to the customer and to the          
    operator to see the information displayed.   

 
 

SWITCHING THE ECR ON/OFF 

 

 

The ECR comes complete with mains adapter. The adapter is intended to operate with /- 22-33V 

/ 50Hz input voltage. 
 

The ECR can be switched on by pressing the key

 

 

On the display is shown:   

OFF

 

The ECR can also be switched off manually by pressing the key  

<0>

 . 

If the ECR is into a sub-mode, the operator can turn it back into 'OFF' mode by pressing the key 

<OFF>.

 

From  any  state  the  ECR  can  be  switched  off  (emergency)  by  simultaneously  pressing  the  keys:

 

*

PY1

PY2

 

 

 

Turn the ECR mains adapter on, to charge the built in accumulator 24 hours before 
starting to use the ECR! 
Before starting work, check whether there is paper inserted into ECR! 

 

 

Содержание dp-55d kosovo

Страница 1: ...Datecs USERS MANUAL 21 06 2011 1 ELECTRONIC CASH REGISTER DP 55D Kosovo...

Страница 2: ...eration for their correct usage and maintenance DP 55D are cash registers with possibilities which conform to the customer service requirements and financial accounting in shops supermarkets pharmacie...

Страница 3: ...re exit b ECR which serves one stand Types of payment 1 Cash cheque credit card coupon 2 Cash with alternative currency USD ECR operation modes REG Registration Programming Report Test Z Report with c...

Страница 4: ......

Страница 5: ...d which able both to the customer and to the operator to see the information displayed SWITCHING THE ECR ON OFF The ECR comes complete with mains adapter The adapter is intended to operate with 220VAC...

Страница 6: ...ettings 5 S Service mode available If the service jumper is activated 6 GPRS Configuration GPRS available If the service jumper is activated 7 FM Read FM available If the service jumper is activated 8...

Страница 7: ...number business registration number the Identification number of the tax obligated person and VAT rates 3 Fiscalization to ECR FUNCTION OF THE KEYS IN PROGRAMMING MODE The programming of parameters is...

Страница 8: ...L must be pressed If the operator omit to press the TOTAL key the last made modifications will be lost When editing a symbol field the symbols are chosen by consecutively pressing a key and if the key...

Страница 9: ...guage Up to 22 characters Default For row 1 20 PLU 1 PLU 20 For row 21 5000 filled with spaces 3 Price Up to 8 digits Default 0 00 5 Inventory group 0 9 Default For row 1 8 1 8 For row 9 5000 9 Note I...

Страница 10: ...s key in order to move on the field 13 the item s name in albanian language 5 Press key STL in order to move in editing mode 6 Enter the name of the item BUKA as the follows B 8 8 U 2 2 K 5 5 A 8 7 Ac...

Страница 11: ...eipts in REG mode 0 1 2 0 Disabled permitted sales from the keyboard of ECR there isn t communication with PC there isn t mode fiscal printer 1 Enabled programming between the receipts in REG mode per...

Страница 12: ...xt in english During fiscalization the texts are recorded in the fiscal memory After fiscalization they can be changed only if the service jumper is activated Up to 20 changes per fiscal memory are po...

Страница 13: ...x obligated person 15 symbols Default 0 Note If the default value of the identification numbers of the tax obligated person is not changed this will not permit the setting of the fiscal memory into us...

Страница 14: ...entered than PRC is pressed Than the item desired should be specified BAR Select an item by its barcode By pressing the key BAR after entering a number on the display appears BARKODE and makes the sa...

Страница 15: ...y PY2 is pressed A dialog screen appears 3 KUPON 4 USD 2 QEK Press the appropriate numeric key to choose the payment desired When the choice is made if possible a payment is performed A mixed payment...

Страница 16: ...ntered and after the is used it will cause the prior entered value to be adds to the subtotal Discount by value The using of this sequence will cause the prior entered value to be subtracted from the...

Страница 17: ...item of the range is determined with entering the row number from table 1 and presiing the or key Using the keys and you can move forward and backward over the table 1 rows Pressing the key TOTAL sta...

Страница 18: ...d the registers involved are cleared automatically When the field 7 of table 2 is set to 1 the turnovers and quantities of the items are also cleared STL Reporting and clearing the operators debts On...

Страница 19: ...mber Detailed Month Report 3 STL VD X MMYY Detailed report for period determined by date to date that is submitted at GPRS terminal 1 STL X DDMMYY DDMMYY BAR Month report that is submitted at GPRS ter...

Страница 20: ...field 9 For programming and reporting is used the application Ecr Tool or its analog OFF LINE ERROR CODES AND MESSAGES Error codes Error code Description Solution ERROR 01 Printing device failure ERRO...

Отзывы: