![Datcon DT7000 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/datcon/dt7000/dt7000_operating-instructions-manual_3743784019.webp)
DT7000
20171206-V1
19
7. Fault rectification
7.1. Fault finding
The fault finding must be carried out by trained and
authorized personnel only!
Use only an Ex proofed meter when measuring in the
hazardous area.
•
There is no value displayed on the LCD
→
check the
supply voltage on the cable socket connector. If the supply
voltage is OK: the instrument is defective.
•
There is change in the pressure but there is no change on
the display
→
check the pressure tubes and the pressure
connections. If the tubes and the connections are OK: the
instrument is defective.
If the fault finding is not successful call the manufacturer
service department.
7.2. Repairing
There is no user repairable part inside the instrument.
In accordance with Point
2.1.: For safety and warranty
reasons, any internal work on the instrument must be
carried out by DATCON personnel.
Содержание DT7000
Страница 1: ...DT7000 Intrinsically Safe Differential Pressure Meter Transmitter Operating Instructions...
Страница 10: ...DT7000 10 20171206 V1 4 2 Main dimensions of the instrument...
Страница 15: ...DT7000 20171206 V1 15 1 Figure 2 Figure...
Страница 23: ...DT7000 20171206 V1 23 9 2 Application example...
Страница 24: ...DT7000 24 20171206 V1 9 3 ATEX Certification...
Страница 25: ...DT7000 20171206 V1 25...
Страница 26: ...DT7000 26 20171206 V1...
Страница 27: ...DT7000 20171206 V1 27...
Страница 28: ...DT7000 28 20171206 V1...
Страница 29: ...DT7000 20171206 V1 29...
Страница 30: ...DT7000 30 20171206 V1...
Страница 31: ...DT7000 20171206 V1 31...
Страница 32: ...DT7000 32 20171206 V1...
Страница 33: ...DT7000 20171206 V1 33...
Страница 34: ...DT7000 34 20171206 V1...
Страница 35: ...DT7000 20171206 V1 35...
Страница 36: ......