5.3. Mounting procedure

 

The following figure shows the mounting procedures (fixing 
on the rail): 

 

 
 

Mounting on the rail

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
The mounting doesn’t need any tools. 
1. Tilt the instrument according to the figure; put the 
instrument’s mounting hole onto the upper edge of the rail 
(figure step 1.). 
2. Push the instrument’s bottom onto the bottom edge of 
the rail (figure step 2.), you will hear the fixing assembly 
closing. 
3. Check the hold of the fixing by moving the instrument 
firmly. 
 

 

Содержание DT1364

Страница 1: ...DT1364 Intrinsically Safe NAMUR Contact Isolators Operating Instructions...

Страница 2: ...figuration 7 3 2 Principle of operation 7 3 3 Adjustment 8 3 4 Indicators 9 3 5 Storage and transport 10 4 Setting up the operating modes 11 4 1 Open the instrument housing 11 4 2 Setting up operating...

Страница 3: ...Fault rectification 19 7 1 Fault finding 19 7 2 Repairing 19 8 Dismounting 20 8 1 Dismounting procedure 20 8 2 Disposal 21 9 Appendix 22 9 1 Technical specification 22 9 2 Application example 24 9 3...

Страница 4: ...e personnel and put into practice by them 1 3 Symbolism used Information tip note This symbol indicates helpful additional information Caution warning danger This symbol informs you of a dangerous sit...

Страница 5: ...he instrument can give rise to application specific hazards or damage to system components through incorrect mounting or adjustment 2 4 General safety instructions The DT1364 is a high tech instrument...

Страница 6: ...safety information for installation and operation in Ex areas 2 7 Environmental instructions Protection of the environment is one of our most important duties Please take note of the instructions writ...

Страница 7: ...area of zone 0 or zone 1 The instrument galvanic isolates the input the output and the power supply The safe outputs are SPDT relay contacts The DT1364 has two built in mode control switches one per...

Страница 8: ...through a 1 kohm resistor A multilevel comparator detects the current consumption of the sensor according with NAMUR standard The levels are as follows 2 1 mA ON near state 1 2 mA OFF far state 0 15 m...

Страница 9: ...or indicates Ch1 line fault state 3 yellow indicator indicates Ch1 output active state 4 red indicator indicates Ch2 line fault state 5 yellow indicator indicates Ch2 output active state 6 red indicat...

Страница 10: ...title Environmental conditions The packaging of DT1364 consist of environment friendly recyclable cardboard is used to protect the instrument against the impacts of normal stresses occurring during t...

Страница 11: ...DIL switches SW1 SW2 SW3 SW4 To reach the DIL switches the instrument housing shall be open 4 1 Open the instrument housing The following figure shows how to open the instrument housing Open the inst...

Страница 12: ...ck the cover as far as both of the DIL switches can be seen figure step 5 There is no need to use great force for pushing the opening lever Please do not exercise forces higher than necessary 4 2 Sett...

Страница 13: ...ck if any alien materials left in the housing If there are remove them The figure above shows how to close the instrument housing 1 Push back the cover figure step 1 you will hear the fixing levers cl...

Страница 14: ...re in accordance with chapter 9 1 Technical specification as described under the title Operating conditions Mounting position The instruments are designed in a housing for mounting on TS 35 rail The i...

Страница 15: ...ounting doesn t need any tools 1 Tilt the instrument according to the figure put the instrument s mounting hole onto the upper edge of the rail figure step 1 2 Push the instrument s bottom onto the bo...

Страница 16: ...regulations conformity and type approval certificates of the DT1364 and other connecting instruments e g detector The connection must be carried out by trained and authorized personnel only Connect on...

Страница 17: ...ts see also Application example Be careful the polarity of the cables Checking the connections 1 Loosen terminal screws 2 Insert the wire ends into the open terminals according to the wiring plan 3 Sc...

Страница 18: ...wiring plan 3 Screw the terminal in 4 Check the hold of the wires in terminals by pulling on them firmly Check if the cables are connected properly have you connected all the cables have you connecte...

Страница 19: ...K the instrument is defective One of the two channel doesn t work exchange the detector If the channel works properly the detector is defective When the result of fault finding is that the DT1364 is d...

Страница 20: ...t lower terminals or push down upper terminals the screwdriver handle as far as the terminals will be free figure step 2 Dismount the instrument 3 Put the screwdriver end into the fixing assembly s ho...

Страница 21: ...cerning EU directive the manufacturer undertakes the disposal of the instrument that are manufactured by it and intended to be destroyed Please deliver it in contamination free condition to the site o...

Страница 22: ...EN 60947 5 6 NAMUR No load voltage 8 2 V Short circuit current 8 2 mA Input resistance 1000 ohm Low current input version upon request No load voltage 8 2 V Short circuit current 0 5 mA max Input resi...

Страница 23: ...tibility EMC accordance with the standard EN 61326 1 Immunity Industrial area Noise emission Group 1 Class B Data in general Design TS 35 rail mounting housing material polyamide PA6 6 Connection plug...

Страница 24: ...DT1364 24 20171206 V0 9 2 Application example...

Страница 25: ...DT1364 20171206 V0 25 9 3 ATEX Certification...

Страница 26: ...DT1364 26 20171206 V0...

Страница 27: ...DT1364 20171206 V0 27...

Страница 28: ...DT1364 28 20171206 V0...

Страница 29: ...DT1364 20171206 V0 29...

Страница 30: ...DT1364 30 20171206 V0...

Страница 31: ...DT1364 20171206 V0 31...

Страница 32: ...DT1364 32 20171206 V0...

Страница 33: ...DT1364 20171206 V0 33...

Страница 34: ...DT1364 34 20171206 V0...

Страница 35: ...DT1364 20171206 V0 35...

Страница 36: ......

Отзывы: