Firmware Update
Datavideo usually releases new firmware containing new features or reported bug fixes from time
to time. Customers can either download the TLM-170F firmware as they wish or contact their local
dealer or reseller for assistance.
This section outlines the firmware upgrade process which should take
approximately 20 minutes
to complete
.
The existing TLM-170F settings should persist through the
firmware upgrade process, which
should not be interrupted once started
as this could result in a non-responsive unit.
Successful firmware upgrade on TLM-170F requires:
Latest TLM-170F firmware version
USB 2.0 Portable Drive (Max. 16GB)
USB A Cable
To update the TLM-170F firmware
MCU
1.
Unzip / extract the firmware file.
2.
Rename the bin file to “mcu.bin”.
3.
Format the USB 2.0 pen drive to FAT32.
4.
Copy mcu.bin to the USB 2.0 pen drive.
5.
Power off the TLM-170F (On/Off Switch at the back of the monitor)
6.
At the back of the monitor, plug the USB 2.0 pen drive into the USB 2.0 port labelled
SERVICE
.
7.
Power ON the TLM-170F while pushing down the EXIT key.
8.
Release the EXIT key when the F1 button LED starts flashing (the firmware is being
updated). The TLM-170K should reboot automatically after the update is complete.
9.
To check the firmware versions, push down the EXIT key for 3 seconds then release; push
down the MENU key for another 3 seconds then release; push down the EXIT key for
another 3 seconds again to show the firmware versions on the OSD menu.