background image

 

Rear Panel 

 

 

 

 

 

 

 

 

 

 

 

DC Out 12V 5A 

3 x 12V 5A DC Output via XLR In-Line Socket  

 

 

DC Out 12V 10A 

2 x MAX 12V 10A DC Output via XLR In-Line Socket 

 

 

 

Cooling Fan 

The PD-4A has two built-in cooling fans; please ensure that 

the two fans are not blocked and the airflow is available. 

 
Note: Fan starts when internal ambient temperature 

reaches 50

℃.

 

 

 

Ground Terminal 

When connecting this unit to any other component, make 

sure that it is properly grounded by connecting this terminal 

to an appropriate point. When connecting, use the socket 

and be sure to use wire with a cross-sectional area of at least 

1.0 mm

2

 

 

 

 

 

 

 

Cooling 

Fan 

DC12V / 10A MAX 

XLR Output 

DC 12V / 5A 

XLR Output 

Cooling 

Fan 

Содержание PD-4A

Страница 1: ...PD 4A REDUNDANT POWER CENTER Instruction manual...

Страница 2: ...ation However Datavideo Technologies cannot exclude that some information in this manual from time to time may not be correct or may be incomplete This manual may contain typing errors omissions or in...

Страница 3: ...al power company 8 Do not allow anything to rest on the power cord Do not locate this unit where the power cord will be walked on rolled over or otherwise stressed 9 If an extension cord must be used...

Страница 4: ...ems are not covered under warranty Any errors that are caused by unauthorized third party software installations which are not required by our computer systems are not covered under warranty All mail...

Страница 5: ...nserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling...

Страница 6: ...al The built in time delay power on control initiates each DC output terminal in sequence and each terminal is installed with an auto recover fuse to safely protect every connected working device Feat...

Страница 7: ...ut failed When input falls below 80 5VAC Cooling Fan The PD 4A has two built in cooling fans please ensure that the two fans are not blocked and the airflow is available Note Fan starts when internal...

Страница 8: ...powered from a suitable 12V power source When working from DC the PD 4A will not regulate the power outlets Please ensure that the 12V power source that you use is regulated If you intend to run the P...

Страница 9: ...blocked and the airflow is available Note Fan starts when internal ambient temperature reaches 50 Ground Terminal When connecting this unit to any other component make sure that it is properly grounde...

Страница 10: ...nput fuse rating 100 240VAC MAX 6 3A AC frequency 50Hz or 60Hz DC input One DC 12V supports non regulated DC 12V output DC input watt 300W Output DC Output 12V 5 5A XLR AC Female Jack x 3 12V 5 10A XL...

Страница 11: ...11 Dimensions All measurements in millimeters mm...

Страница 12: ...20 2427338 E mail sales datavideo in Tel 91 0120 2427337 A 132 Sec 63 Noida 201307 India India Noida Datavideo India Kochi Tel 91 4844 025336 Fax 91 4844 047696 2nd Floor North Wing Govardhan Building...