4.3  How to save / load the camcorder settings to / from a PC  

It is possible to save the current settings on all four cameras from MCU-100P to a PC for later use. 

Also any previously saved MCU-100P settings stored on a PC can also be loaded back to the MCU-

100P unit. This can be handy if multiple users have access to the equipment and you need a quick 

way to get back to your preferred settings. 

Use the following procedure to save the current camera settings set by the MCU-100P unit to a PC. 

1.

 

Power off the MCU-100P unit.  

2.

 

Connect the MCU-100P unit to PC using a USB cable via the USB 2.0 (Mini B) interface. 

 

 

 

 

 

3.

 

Set the five 

switches on the MCU-100P unit to their 

middle position.  

4.

 

Press and hold in both the CAM 1 & MU-1 buttons at same time and then power on the 

MCU-100P unit.  

5.

 

The seven segments LED Display will show “

cU--

”, and the PC will detect the MCU-100P 

unit as an external storage device named “

MCU-100P_MUx

”.  

6.

 

Open the “

MCU-100P_MUx

” folder on the PC and copy “

mu_param.bin

” file to desired PC 

hard drive location.  

7.

 

Once complete unplug the USB cable and reboot the MCU-100P unit.  

To load previously saved settings on a PC to MCU-100P, r

epeat steps

 1~5 of the above procedure 

and then continue with the following steps. 

6.

 

Open the “

MCU-100P_MUx

” file folder on PC and delete the “

mu_param.bin

” file.  

7.

 

Copy the previously saved “

mu_param.bin

” file from the PC hard drive location to the 

MCU-100P_MUx

” folder.  

Note:

 Do not worry if the previously saved 

xxxxxxxxx.bin 

file has been renamed on the PC. 

The MCU-100P unit will automatically amend the file name back to “

mu_param.bin

” after 

a reboot.  

8.

 

Once the copy process is complete unplug the USB cable and reboot the MCU-100P unit.  

 

 

 
 
 
 
 
 
 
 
 
 
 

 

Содержание MCU-100P

Страница 1: ...MCU 100P MULTI CAMERA CONTROL UNIT Instruction Manual ...

Страница 2: ... AD 1P FIRMWARE 19 6 DIMENSIONS 20 7 SPECIFICATIONS 21 SERVICE SUPPORT 22 Disclaimer of Product Services The information offered in this instruction manual is intended as a guide only At all times Datavideo Technologies will try to give correct complete and suitable information However Datavideo Technologies cannot exclude that some information in this manual from time to time may not be correct o...

Страница 3: ...e this unit where the power cord will be walked on rolled over or otherwise stressed 9 If an extension cord must be used with this unit make sure that the total of the ampere ratings on the products plugged into the extension cord do not exceed the extension cord rating 10 Make sure that the total amperes of all the units that are plugged into a single wall outlet do not exceed 15 amperes 11 Never...

Страница 4: ...urchase Certain parts with limited lifetime expectancy such as LCD panels DVD drives Hard Drive Solid State Drive SD Card USB Thumb Drive Lighting Camera module PCIe Card are covered for 1 year The three year warranty must be registered on Datavideo s official website or with your local Datavideo office or one of its authorized distributors within 30 days of purchase Disposal For EU Customers only...

Страница 5: ...er and equipment and saves setup time and disk space for you To get more value out of this equipment please take a few minutes to read through this manual This will help familiarizing yourself with all the aspects of the MCU 100P control unit That s Datavideo sharing the value 1 1 Features Four RJ 45 Ethernet ports allow remote setup of up to four Panasonic cameras RJ 45 cabling allows unit to be ...

Страница 6: ...oduct page on our official website for the updated list Note Datavideo has tested and found the above Panasonic cameras to be compatible with the MCU 100P unit However due to the differences between individual Panasonic camera models some features or settings may be limited In most cases the same limitation also applies to the Panasonic AG EC4G unit ...

Страница 7: ...7 2 System Diagram ...

Страница 8: ...12V DC Input This 9 pin Mini Din port can be used for confidence and composition monitoring and in some cases to view the camera s own LCD OSD menus To use this feature please connect the Mini Din end of the CB 40 cable 1 Mini Din to 4 CV Out to this port CB 40 is an optional accessory ...

Страница 9: ... and Panasonic cameras or camcorders One side of the box connects to the MCU 100P via an Ethernet cable and the other side connects to Panasonic cameras or camcorders via a Panasonic CAM BS cable Users are allowed to use an Ethernet cable that runs 300 meters to connect the MCU 100P to this adapter box which in turn connects a Panasonic camera The CV output connects the monitor which will display ...

Страница 10: ...cted the menu and other functions of the Panasonic camera may be limited to remote control only To regain manual control of the menu functions at the camera first disconnect the AD 1P The AD 1P also features a BNC type Composite CV output which can be taken to an SD monitor on or near the camera This Composite output can be used for confidence and composition monitoring and in some cases to view t...

Страница 11: ...wer the MCU 100P On or Off Camera selection Select the button for the camera that you wish to control Camera Selection Memory Store Recorder Control Shutter Selection Save Menu Gain Camera Video Signals Enable White Black Balance USB for F W Upgrade IRIS Adjustment LED Display Check ...

Страница 12: ...he user defined functions of the USER MAIN USER1 and USER2 buttons on the chosen camera Operation will follow the function that was assigned by the user in the chosen cameras OSD menu NOTE USER 2 buttons will work as a thumbnail ON switch for the AG HP255 and AG HPX371 MENU button is back lit orange at this time Data save save defined functions from the camera When this function is enabled the but...

Страница 13: ...options Pressing in the same dial like a button confirms the current selection or value shown When the MENU button is NOT active and back lit green The select dial can be turned to adjust the SHUTTER speed of the camera AWB ABB switch with LED This switch is used to trigger Auto White Balance AWB or Auto Black Balance ABB adjustment AWB White balance is adjusted automatically When the W BAL switch...

Страница 14: ...ut CAM AUTO KNEE OFF The images shot by camera are output The AUTO KNEE circuit does not work MANUAL KNEE is set as the camera recorder s initial setting CAM AUTO KNEE ON The images shot by the camera are output The AUTO KNEE circuit works NOTE AUTO KNEE circuit will not be effective if DRS Dynamic Range Stretch function is enabled It is also possible allocate the MANUAL KNEE and DRS functions via...

Страница 15: ...s are shown on the display below in this order each time the CHECK button is pressed If the CHECK button is pressed and held down for over two seconds the MCU 100P unit will switch in to LOCK mode LED display The IRIS value Shutter degree speed Gain and Filter positions can be displayed here by using the CHECK button The M PED PAINTING GAIN R B and BLACK R G B values can also be displayed sequenti...

Страница 16: ...re currently not in use The user may activate these functions via an associated ENABLE button 2 LOCK This mode is activated by pressing and holding down the CHECK button for two seconds When in LOCK mode all functions are unavailable except for the 4 Camera selection buttons and the CHECK function This is to prevent unauthorized or unintended operation during a LIVE production The seven segment LE...

Страница 17: ...e Memory Store functions Internally the unit has three memory blocks indicated by the Memory Stores MU 1 MU 2 and MU 3 Each of these blocks is divided into four segments one segment for each camera These are used to store the settings for each camera accordingly Use this procedure to store the settings on a camera to the MCU 100P unit s internal memory 1 Select the camera from which you want to co...

Страница 18: ...e time and then power on the MCU 100P unit 5 The seven segments LED Display will show cU and the PC will detect the MCU 100P unit as an external storage device named MCU 100P_MUx 6 Open the MCU 100P_MUx folder on the PC and copy mu_param bin file to desired PC hard drive location 7 Once complete unplug the USB cable and reboot the MCU 100P unit To load previously saved settings on a PC to MCU 100P...

Страница 19: ...s the MCU 100P 5 1 How to update the MCU 100P firmware 1 Turn off the MCU 100P device power 2 Connect the MCU 100P to the PC via a USB cable 3 Set the five switches on the MCU 100P to their middle position 4 Move switch up towards AWB and at the same time also press the shutter select button Hold both in place 5 Turn on the MCU 100P power 6 MCU 100P LED display will show L x x and the PC will find...

Страница 20: ...20 6 Dimensions All measurements in millimeters mm ...

Страница 21: ... Speed and Degree Functions Iris Adjustment AWB ABB Functions White Balance A B and Preset Functions Camera Knee Bars Functions Camera Gain Adjustment RGB Black Level R B Gain and Master Pedestal Controls Compatible Camera Models AG HPX255 AG HPX300 AG HPX301 AG HPX302 AG HPX304 AG HPX370 AG HPX370P AG HPX371 AG HPX372 AG HPX500 AG HPX502 AG HPX600 AG HPX600P AJ HDX900 AJ HPX2700 AJ HPX2700G AJ HP...

Страница 22: ...91 0120 2427338 E mail sales datavideo in Tel 91 0120 2427337 A 132 Sec 63 Noida 201307 India India Noida Datavideo India Kochi Tel 91 4844 025336 Fax 91 4844 047696 2nd Floor North Wing Govardhan Building Opp NCC Group Headquaters Chittoor Road Cochin 682035 India Kochi Datavideo Technologies Europe BV Floridadreef 106 3565 AM Utrecht The Netherlands Tel 31 30 261 96 56 Fax 31 30 261 96 57 E mail...

Отзывы: