background image

 

 

 

 
 

Front Panel DN-600 continued 

 

 

Record  

In Idle  Mode,  pressing  the  'PLAY'  while  the  'REC'  button  is  held  down 
will make the unit ready to record. 

 

Play / Pause  

From  the  Stop  or  Idle  mode,  pressing  the  'PLAY'  button  plays  back 
video  from  the  selected  bin. While  playing,  pressing  the  'PLAY'  button 
will toggle between 'PLAY' and 'PAUSE'. 

 

Stop  

In PLAY Mode, pressing the 'STOP' button will end play back and enter 
the Stop mode. In RECORD Mode, pressing the 'STOP' button will end 
recording and enter the Stop mode. 
 

 

DV/ HDV in out 

A standard IEEE-1394 port for connecting a DV25 or HDV Camcorder. 
 

Cannot be used for file transfer to a computer. 
 

 

 

Level Adjustments  

The  Audio  Level  Adjustments  allow  you  to  adjust  the  headphones 
volume. 
 

 

 

headphones Jack 

Accepts a stereo mini jack plug for stereo headphones. The headphone 
volume is controlled by the Audio Level Adjustments. 
 

 

Audio Level  

The  Audio  Input  Level  LEDs  show  the  audio  input  levels  from  the 
incoming source. 

 

 

Drive bay for removable HE-1 drive enclosure  

For  insertion  of  the  removable  HE-1  drive  enclosure.  The  HE-1  drive 
enclosure can be fitted with a SATA 2.5” HDD. See page 6. 
 
 

 
 

 

Содержание DN-600

Страница 1: ...Analogue Digital Recorder DN 600 Instruction Manual Rev Date 19 09 2013 P N G082060618E1 WWW DATAVIDEO COM...

Страница 2: ...the signal type 17 Select which time code to use 17 How to prepare to record from an analogue input 18 Wired Connections 18 Set the unit to record from an analogue source ANA 18 Choose the file type...

Страница 3: ...9 Summary List of Commands 29 Connector Pin Assignment 29 System Control 30 Sense Request 30 Transport Control 31 Dimensions 33 Specifications 33 Service and Support 34 Disclaimer of Product and Servi...

Страница 4: ...hat the total of the ampere ratings on the products plugged into the extension cord do not exceed the extension cord rating 10 Make sure that the total amperes of all the units that are plugged into a...

Страница 5: ...For information on how to register please visit www datavideo com or contact your local Datavideo office or authorized Distributors Certain parts with limited lifetime expectancy such as LCD Panels D...

Страница 6: ...p to 750GB the DN 600 is capable of long duration recordings and even SD based time lapse recordings All in all we feel the DN 600 is well suited to live event recording and post production applicatio...

Страница 7: ...ove the PCB 2 Seat your 2 5 SATA HDD on to the PCB and then turn it over so you can secure the drive to the PCB using the four screws holes provided 3 Return the PCB with HDD fitted to the enclosure u...

Страница 8: ...the time number will be the length of the content in this bin The fourth line labels the soft keys Menu Navigation Left Right soft key The functions of the two Soft Keys found below the LCD are depen...

Страница 9: ...nd recording and enter the Stop mode DV HDV in out A standard IEEE 1394 port for connecting a DV25 or HDV Camcorder Cannot be used for file transfer to a computer Level Adjustments The Audio Level Adj...

Страница 10: ...site Video input output The connection is composite video input AUDIO IN Accepts a RCA jack plug for audio input Left Right TC IN The connection is for time code single input DC In Socket The connecti...

Страница 11: ...switch is located on the rear of the unit Formatting a drive before first use Once a drive has been installed into the HE 1 drive enclosure as described on page 7 it will need to be formatted in the...

Страница 12: ...ge from MAKING MEDIA FILES to EMPTY THIS BIN to SELECT SOURCE When all menu options have been navigated you will return to the first option again In some cases the currently selected option will be co...

Страница 13: ...e avi or mov EMPTY THIS BIN Empties or erases the video and audio content within the current BIN This step cannot be undone once the final question has been asked SELECT SOURCE When in DV Standard Def...

Страница 14: ...Note that the current selection will be marked with an asterisk SET RECORD DATE This option modifies the date attribute of the created file when the source is analogue CVBS It is also used when the s...

Страница 15: ...anel PWR ON AUTO PLAY When enabled the recorder will go directly into a play mode in the last BIN selected once power is applied It will then play the whole BIN or just the selected CLIP within the cu...

Страница 16: ...hen connecting the HDD to a computer the disk will have for volume name Mediapac xx This option sets the xx value A useful feature when connecting multiple volumes at the same time as from a multi sho...

Страница 17: ...second partition Deleting all bins will not erase the data in the second partition either See page 16 for further details Note Changing partition count will erase the content in all bins so is best do...

Страница 18: ...key to navigate to the file type required Use the left hand soft key to select file setting An asterix symbol will be displayed next to file type when selected Press the MENU button to exit the option...

Страница 19: ...t hand soft key to ENTER the menu option Use the right hand soft key to navigate to the SET RECORD FILE TYPE option Use the left hand soft key to ENTER the menu option Use the right hand soft key to n...

Страница 20: ...o the SET RECORD FILE TYPE option Use the left hand soft key to ENTER the menu option Use the right hand soft key to navigate to the file type required Use the left hand soft key to select file settin...

Страница 21: ...on 3 Using the Remote Serial interface See the command protocol at the rear of this manual 4 Simple contact closure circuit using a switch contact or button wired to the GPI port on the recorders rear...

Страница 22: ...an be set up to capture from one of six time lapse settings They are 1 frame per second 1 frame per 2 seconds 1 frame per 5 seconds every 4 th frame every other frame or 1 frame per trigger The trigge...

Страница 23: ...ause the playback to go faster in the chosen direction up to 32x speed A speed other than 1x is displayed in the bottom line of the LCD panel While playing video pressing the Menu button will give an...

Страница 24: ...th both Macs and PCs This format limits the size of a file to a maximum of 2GB that translates to approximately nine minutes of video A clip that lasts longer than nine minutes is broken into multiple...

Страница 25: ...1 drive enclosure is fitted with a mini USB connector on its rear this can provide power to the HDD as well as allow the exchange of data Note With some PCs and Laptops the USB bus power may not be e...

Страница 26: ...his method This section describes the firmware update process for the recorder if you have all the items required it should take approximately 20 minutes total time to complete Please contact your loc...

Страница 27: ...and then press the Play button This should start the record process The button on the connected GPI cabling is then pressed forcing the unit into record pause mode The unit is then ready to activate...

Страница 28: ...us Display and navigation buttons select a pre recorded video BIN Make sure the output device monitor is connected and working with the recorder Press in the Play button on the recorder s front panel...

Страница 29: ...a three byte acknowledgement ACK if the Checksum is valid If the Checksum is not valid the DN Recorder will ignore the command Most commands will be responded to within 8 msec However a PLAY command f...

Страница 30: ...the present time code in Binary Coded Decimal The first byte holds the frame number the second byte holds the seconds the third the minutes and the fourth the hour In the play state the time code ret...

Страница 31: ...2h Record The video is recorded from the selected source onto the current Bin This command may be issued only from the idle state 20h 10h Fast Forward A play state where video is played at the highest...

Страница 32: ...verse 10h 01h 11h ACK 21h 22h nnh csum Variable Reverse 10h 01h 11h ACK 21h 23h nnh csum Shuttle Reverse 10h 01h 11h ACK 21h 11h 00h 32h Play Pause 10h 01h 11h ACK 24h F0h nn csum Select Bin and Play...

Страница 33: ...andwidth 20 20KHz 3dB S N Ratio 50 dB THD 0 15 Time Code In SMPTE 0 5V to 5 0V p p BNC Digital Video In Out IEEE 1394 400Mbps max 6 pin GPI Trigger 1 65V Threshold 100K Ohms input contact closure Reco...

Страница 34: ...ed Tel 44 1457 851 000 Fax 44 1457 850 964 E Mail sales datavideo co uk Datavideo Technologies Co Ltd Tel 886 2 8227 2888 Fax 886 2 8227 2777 E mail service datavideo com tw Datavideo Technologies Chi...