background image

 

FCC Compliance Statement 

This device complies with part 15 of the FCC rules. Operation is subject to the following 

two conditions: 

 

(1)

 

This device may not cause harmful interference, and  

(2)

 

This device must accept any interference received, including interference that may 

cause undesired operation. 

 

Warnings and Precautions 

1.

 

Read all of these warnings and save them for later reference. 

2.

 

Follow all warnings and instructions marked on this unit. 

3.

 

Unplug this unit from the wall outlet before cleaning. Do not use liquid or aerosol 
cleaners. Use a damp cloth for cleaning. 

4.

 

Do not use this unit in or near water. 

5.

 

Do not place this unit on an unstable cart, stand, or table. The unit may fall, causing 
serious damage. 

6.

 

Slots and openings on the cabinet top, back, and bottom are provided for 
ventilation. To ensure safe and reliable operation of this unit, and to protect it from 
overheating, do not block or cover these openings. Do not place this unit on a bed, 
sofa, rug, or similar surface, as the ventilation openings on the bottom of the 
cabinet will be blocked. This unit should never be placed near or over a heat 
register or radiator. This unit should not be placed in a built-in installation unless 
proper ventilation is provided. 

7.

 

This product should only be operated from the type of power source indicated on 
the marking label of the AC adapter. If you are not sure of the type of power 
available, consult your Datavideo dealer or your local power company. 

8.

 

Do not allow anything to rest on the power cord. Do not locate this unit where the 
power cord will be walked on, rolled over, or otherwise stressed. 

9.

 

If an extension cord must be used with this unit, make sure that the total of the 
ampere ratings on the products plugged into the extension cord do not exceed the 
extension cord’s rating. 

10.

 

Make sure that the total amperes of all the units that are plugged into a single wall 
outlet do not exceed 15 amperes. 

11.

 

Never push objects of any kind into this unit through the cabinet ventilation slots, 
as they may touch dangerous voltage points or short out parts that could result in 
risk of fire or electric shock. Never spill liquid of any kind onto or into this unit. 

Содержание DAC-50S

Страница 1: ......

Страница 2: ...correct complete and suitable information However Datavideo Technologies cannot exclude that some information in this manual from time to time may not be correct or may be incomplete This manual may...

Страница 3: ...the ventilation openings on the bottom of the cabinet will be blocked This unit should never be placed near or over a heat register or radiator This unit should not be placed in a built in installatio...

Страница 4: ...r controls may result in damage to the unit and may often require extensive work by a qualified technician to restore the unit to normal operation e When the product has been dropped or the cabinet ha...

Страница 5: ...e disposed of with your other household waste Instead it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electr...

Страница 6: ...ther outputs one pair of analog audio channels selected from 16 de embedded SDI audio channels Selection is determined by DIP switch settings The DAC 50S is housed in a rugged aluminum frame making it...

Страница 7: ...DI input source HD SD SDI Output HD SDI loop thru output USB Firmware Upgrade Connects to PC for firmware upgrade DC In Socket Connects the supplied 12V PSU to this socket The connection can be secure...

Страница 8: ...grade 1 1 1 CH15 CH16 NOTE Given a 16 9 HD video input if DIP SW5 is set to 16 9 the image displayed on a 4 3 TV monitor will be anamorphic i e the image will be compressed laterally However if DIP SW...

Страница 9: ...9 Front Panel Y Output Port Component video output port U Pb CV Output Port Component or Composite video output port V Pr C Output Port Component video output port...

Страница 10: ...10 CV Output Port Composite video output port Audio OUT SDI audio de embed output via 2 unbalanced analog audio channels...

Страница 11: ...rmware update process Once started the update process should not be interrupted in any way as this could result in a non responsive unit Host Update 1 Set DIP SW8 to ON 2 Connect DAC 50S to the PC usi...

Страница 12: ...shown in the diagram below 6 Update is complete after the device is safely removed unplug the USB cable and set DIP SW8 to OFF FPGA Update 1 Set DIP SW7 SW8 to ON 2 Connect the power to the device 3 U...

Страница 13: ...FPGA firmware file into the device 6 The firmware update will now start which takes approximately 2 minutes 7 After the firmware file is successfully copied into the device safely remove the USB devic...

Страница 14: ...low all the suggested solutions If problem still exists please contact your distributor or the service center No Problems Solutions 1 Severe color bar noise is seen on the DAC 50S output terminal if t...

Страница 15: ...nput Format 1080p 50 59 94 Hz 1080i 50 59 94 Hz 720p 50 59 94 Hz NTSC 525 29 97 PAL 625 25 Output Format 625 25 PAL 525 29 97 NTSC F W Upgrade mini USB x 1 DIP Switches 8 PIN DIP Switch 1 SDI audio de...

Страница 16: ...16 Service Support...

Отзывы: