background image

 

Programming mode 

To enter programming mode turn the ignition on then hold down both buttons on the remote control for 3 
seconds; the alarm will now start to chirp (one chirp, then 2 chirps, then 3 chirps and finally 4 chirps). Select 
the item to be programmed by releasing the buttons after the appropriate chirp count. 
 
Programmable items:

 

1 chirp: 

Movement sensitivity 

2 chirps: 

Arm/disarm tones 

3 chirps: 

Auto re-arm 

4 chirps: 

Auto arming

 

5 chirps

: Reset to defaults 

Once an item has been selected the LED will flash and alarm will chirp to show the current setting. 
 
To change the setting, press the large remote button to change up or the small button to change down, the 
setting will roll round in either direction. 
 
To exit and save the desired setting, turn the ignition off or wait 30 seconds without pressing either button. 
The alarm will give one long beep when exiting programming mode. 
 

Movement sensitivity LED flashes 

The LED will flash in sets of 1 up to 4 indicating the current setting:

 

1. 

Off 

2. 

Low sensitivity 

3. 

Medium sensitivity (default) 

 

4. 

High sensitivity

 

 

Arm/disarm tones LED flashes 

The LED will flash to indicate the chosen option, press large button to progress to next level. 

1 flash

: Tones Off (default) 

2 flashes

: Tones On Quiet 

3 flashes

: Tones On Loud 

 

Automatic Arming LED flashes 

The LED will flash to indicate the chosen option, press large button to progress to next level. 

1 flash

: Off (default)    

2 flashes

: Arm after 30 secs    

3 flashes

: Arm after 1 min    

4 flashes

: Arm after 2 mins 

 

Auto re-arm LED flashes 

The LED will flash in sets of two if the auto re-arm function is on and single flashes if the auto re-arm function 
is off. Default is off. When enabled, if the alarm is disarmed and left for 30 sec without manual arming or 
turning the ignition on then the alarm/immobiliser will automatically re-arm. 
 

Reset to defaults LED flashes

 

To reset the alarm to the factory default setting set the LED to flash twice. To exit without resetting to defaults 
set the LED to flash once. 
 

Adding/ removing remote controls 

With the alarm is in disarmed state turn the ignition on/off/on/off/on within 7 seconds. The LED will start to 
flash rapidly for 3 seconds then flash slowly a maximum of 9 times. Count the LED flashes, and then switch the 
ignition off when the LED flash equals that of the first digit of the PIN code. Zero would be input by 
immediately switching the ignition off after the rapid flashing of the LED. 
 
Switch the ignition on and start the LED count process again for the 2

nd

 digit of the PIN. Repeat for the third 

and fourth digits. If the PIN code has been entered correctly the alarm will chirp twice. If the PIN code is 
entered incorrectly the alarm will chirp three times, at this point the PIN code can be entered twice more 
before ignoring the PIN code entry for two minutes. 
 
Pressing a remote control, existing or new will add this to the system and delete all previously entered remote 
controls. Press each remote control that you require to be added; the siren will chirp and the LED will flash for 
acknowledgement of the remote control. If the maximum number of remotes has been reached then a long 
beep will be heard indicating that the last remote pressed has not been saved. 
Turning on the ignition, pressing an already entered remote control or not pressing a button on a new remote 
control for 30 seconds will exit this mode. On exit the alarm will chirp twice and the LED will flash the number 
of stored remotes. A maximum of 6 remotes can be stored. 

 

EVO

PLUS

 

Alarm with Single Circuit Immobilisation 

 

User Guide

 

Revision 7 | December 2017

 

 

The Remote Control 

All DATATOOL 

EVO

PLUS 

systems come with 2 remote controls as 

standard. It is possible to add up to 4 extra remote controls (6 in total). 
 
The large button controls the main arm/disarm functions of the system. 
 
The smaller button is used to initiate secondary functions such as 
movement sensor deletion (transport mode) and locate. Detailed 
operating instructions follow further in this manual. 
 
When either button is pressed on the remote control, the LED will flash 
briefly to confirm the button has been pressed. If the button is held 
depressed the LED will flash approximately once a second for a maximum 

of 

25 flashes. 
 

Changing the Remote Battery

 

Each remote control contains a single long life lithium battery (CR2016). To replace the battery, locate the 
recess in the casing edge and gently prise the upper and lower casing of the remote apart at this point. 
The battery is retained by a spring and can be replaced by simply sliding the battery out from under the 
spring, noting the polarity and replacing with new. Ensure the battery polarity is correct when installing 
the new battery. Align the two casing halves and squeeze firmly to click the casing back together, ensuring 
the joint is even around the circumference. 
 
 

 

www.datatool.co.uk

  

Datatool is a brand of Scorpion Automotive Ltd  
Scorpion House, Drumhead Road, Chorley North Business Park 
Chorley, Lancashire, UK.          

 

Thank you for choosing the  DATATOOL 

EVO

PLUS

 - a motorcycle, scooter and 

quad alarm with single circuit immobilisation capability. 
 
This security system is designed as a deterrent and is not in itself a guarantee 
against theft prevention. We advise you that the more difficult you make your 
machine to be stolen, the lower the potential theft risk.  
 
Applying  common  sense  and  securing  your  machine  with  additional  security 
every time you park plays a large part in this.  
 
Please retain this user guide for future reference. 