background image

To exit long term storage mode, turn on the ignition. An ascending tone will be heard and the large 
remote control button must be pressed within 10 seconds otherwise the alarm will sound. 
 

Programming mode 

To enter programming mode turn the ignition on then hold down both buttons on the remote control for 
3 seconds; the alarm will now start to chirp (one chirp, then 2 chirps, then 3 chirps and finally 4 chirps). 
Select the item to be programmed by releasing the buttons after the appropriate chirp count. 
 
Programmable items: 
 

1 chirp: Movement sensitivity 
2 chirps: Arm/disarm tones 
3 chirps: Auto re-arm 
4 chirps: Reset to defaults 

  
Once an item has been selected the LED will flash to show the current setting. 
 
To change the setting, press the large remote button to change up or the small button to change down, 
the setting will roll round in either direction. 
 
To exit and save the desired setting, turn the ignition off or wait 30 seconds without pressing either 
button. The alarm will give one long beep when exiting programming mode. 
 

Movement sensitivity LED flashes 

The LED will flash in sets of 1 up to 4 indicating the current setting: 

1. Off 
2. Low sensitivity 
3. Medium sensitivity (default)  
4. High sensitivity 

 

Arm/disarm tones LED flashes 

The LED will flash in sets of two if the arm/disarm tones are on and single flashes if the arm/disarm 
tones are off. Default is on. 
 

Auto re-arm LED flashes 

The LED will flash in sets of two if the auto re-arm function is on and single flashes if the auto re-arm 
function is off. Default is off. 
 

Reset to defaults LED flashes

 

To reset the alarm to the factory default setting set the LED to flash twice. To exit without resetting to 
defaults set the LED to flash once. 
 

Adding/ removing remote controls 

With the alarm is in disarmed state turn the ignition on/off/on/off/on within 7 seconds. The LED will start 
to flash rapidly for 3 seconds then flash slowly a maximum of 9 times. Count the LED flashes, and then 
switch the ignition off when the LED flash equals that of the first digit of the PIN code. Zero would be 
input by immediately switching the ignition off after the rapid flashing of the LED. 
Switch the ignition on and start the LED count process again for the 2

nd

 digit of the PIN. Repeat for the 

third and fourth digits. If the PIN code has been entered correctly the alarm will chirp twice. If the PIN 
code is entered incorrectly the alarm will chirp three times, at this point the PIN code can be entered 
twice more before ignoring the PIN code entry for two minutes. 
Pressing a remote control, existing or new will add this to the system and delete all previously entered 
remote controls. Press each remote control that you require to be added; the siren will chirp and the 
LED will flash for acknowledgement of the remote control. If the maximum number of remotes has been 
reached then a long beep will be heard indicating that the last remote pressed has not been saved. 
Turning on the ignition, pressing an already entered remote control or not pressing a button on a new 
remote control for 30 seconds will exit this mode. On exit the alarm will chirp twice and the LED will 
flash the number of stored remotes. A maximum of 6 remotes can be stored. 

 

 

 
 
 

DEMON EVO PLUS 

User Guide 

 

 
 
 

 
 

 
 

Revision: 1.0 Issue May 2015 

 
 
 
 

Datatool is a brand of Scorpion Automotive Ltd 

Scorpion House, Drumhead Road, Chorley North Business Park,  

Chorley, Lancashire, England. 

www.datatool.co.uk 

 

 

Отзывы: