8.1
Basic steps to temperature measurements
• Select a temperature range that matches the expected temperature of the object you
are inspecting.
• Adjusting the temperature scale manually can make it possible to detect anomalies
and smaller temperature differences in the part of the image of interest.
• Selecting a different color palette can make it easier to analyze the image.
• For accurate temperature measurements, it is important to use appropriate measure-
ment parameters.
• For very accurate results, wait 5 minutes after you have started the camera before
measuring a temperature.
8.2
Measurement tools
To measure a temperature, you can use different measurement tools, e.g., a spot or a
box.
1. Result table
2. Hot spot box
3. Temperature scale
8.2.1
Add and remove a tool
On the main toolbar, select
Measurement
. This displays a toolbar, where you can add
the following tools or remove all tools:
• Center spot
• Hot spot box
• Cold spot box
• Hot spot - Spot
• Hot spot - Temp (Delta T)
8.2.2
Move a spot
1. Activate edit mode by tapping the spot on the screen. The spot is now displayed with
a handle.
2. Push the navigation pad or tap the menu button. This displays a toolbar.
#T810624; r. AF/93316/93316; en-US