background image

4209-00009-000   EasyRead (DSV3-EP) User’s Manual 

Rev 0E 

 

6/29/2009 

16 

Copyright © 2009 by Datastrip, Inc.  All rights reserved.   

Reproduction in whole or in part is prohibited. 

5.4.1

 

Charging States 

The 

Power

 

Properties / Battery

 tab window also shows that state of the internal battery charger.  There 

are three charging states.   

 

Main Battery:

  The terminal is operating on battery power and no external AC adapter is 

connected. 

 

External: 

  External AC adapter is connected and the battery is fully charged. 

 

Charging:

  External AC adapter is connected and the battery is charging.  The unit operates 

normally while simultaneously charging the battery.  

5.4.2

 

Battery Charge Level States 

The charge level state of the battery is also listed in the 

Power Properties / Battery

 tab window.  There are 

three charge level states.  When the battery gauge is “Very Low”, the battery should be immediately 
charged by connecting the unit to an AC adapter or the unit will automatically shut down when the 
voltage level drops below the minimum threshold. 

 

Good: 

 Battery charge is Good 

 

Low:  

Battery charge is Low (<10% remaining) 

 

Very Low:  

Battery charge is Very Low / Critical (4% remaining) 

5.4.3

 

Other Indicators 

There are three user warnings that occur when the battery level is “Very Low”:  See sections 4.2 and 4.3 
for the LED and tone indicator states that also provide user feedback regarding battery charge levels and 
charging states. 

 

The power LED alternately flashes Red and Green  (see section 4.3) 

 

A warning message pops up “

Main Battery Very Low

”.  This warning will repeat itself 

periodically until the condition clears or the unit automatically shuts down. 

 

An error beep sounds when the battery charge level is critical. 

5.5

 

Creating Desktop Shortcuts 

To create desktop shortcuts, locate the application for which you want to create a shortcut.  Tap and hold 
the stylus on the application until the options menu pops up.  Select 

Copy

 and go to the directory where 

you want to put the shortcut.  Tap and hold the stylus until the options menu pops up and select “

Paste 

Shortcut

”. 

5.6

 

Safe Boot Mode 

The system provides a mechanism that permits the recovery of lost or damaged 
operating system files via a “Safe Boot” mode.  This mechanism is similar to 
Microsoft Windows Safe Mode that is available on PCs.  If one or more 
operating system files have been damaged or inadvertently deleted, when the 
unit is turned on it will automatically boot-up into a smaller, limited function 
version of Windows CE that will permit the recovery of the files or allow them 
to be replaced or overwritten.  This permits the unit to be repaired, and then 
subsequently rebooted using the full version of Windows CE.  Safe Boot mode 
can also be accessed on demand by holding down the 

F1

 key while turning on 

the power to the unit.  A special bitmap will appear indicating that the unit is 
booting-up in Safe Boot mode. 

6

 

Software Utilities  

All of the utilities listed below except “

DsVerify2About

” are located in the 

My Device\Hard Disk\DSV3

 

directory.  The “

DsVerify2About

” is a hidden file in the 

\My Device\Windows

 directory.  There are 

additional demonstration programs available as source code for custom software development in the 
Datastrip MT SDK (sold separately). 

Содержание DSV3-EP

Страница 1: ...Lead Software Engineer Reviewer __________________________________________________ Date ___________ Scott Robinson Hardware Manager Reviewer __________________________________________________ Date ___...

Страница 2: ...4209 00009 000 EasyRead DSV3 EP User s Manual Rev 0E 6 29 2009 1 Copyright 2009 by Datastrip Inc All rights reserved Reproduction in whole or in part is prohibited EasyRead DSV3 EP User sManual...

Страница 3: ...d stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording scanning or otherwise except as permitted under section 107 or 108 of the 1976 Un...

Страница 4: ...4 10 1 USB Ports 12 4 10 2 Compact Flash CFIO Slot 12 4 10 3 Secure Digital Memory Card SDIO Slot 12 4 10 4 Audio Headset Jack 13 4 11 CONTACTLESS SMART CARD READER 13 4 12 OPTIONAL PERIPHERAL MODULE...

Страница 5: ...nstructions 27 10 6 EPASSPORT ICAO VIEWER ICAO VIEWER EXE 27 10 6 1 EPassport Overview 27 10 6 2 ePassport Security Mechanisms 28 10 6 3 ICAO Viewer Operation 28 11 ACTIVE SYNC 30 11 1 ACTIVESYNC VIA...

Страница 6: ...FIS quality Automated Fingerprint Identification System biometric matching algorithms and rugged biometric sensors All of the DSV3 family of mobile terminals are rugged and environmentally sealed unit...

Страница 7: ...ocumentation User Manual on CD End User License Agreement and Quick Start Guide Please retain the shipping box in the event you need to return your product for service 3 Initial Setup Each unit is shi...

Страница 8: ...l indicate that the system is booting During this time the BIOS is loaded and diagnostic testing is performed When the unit finishes powering up the Windows CE NET desktop will appear on the display 4...

Страница 9: ...rminal is goes into Suspend mode None Button released 1 x 15 sec The terminal is powered OFF normally Falling Tone Button released x 15 sec The terminal performs an emergency shutdown Warning Tone Win...

Страница 10: ...s ON for 4 9 sec and color 2 is ON for 0 1 sec Continuous with Color Blink LED is ON continuously with a 2 5 sec period where color 1 is ON 2 sec and color 2 is ON 0 5 sec Continuous with Color Toggle...

Страница 11: ...powers the Real Time Clock for more than 6 months while the unit is off This battery is automatically recharged by the system and does not require any operator service CAUTION Use ONLY approved replac...

Страница 12: ...matching algorithms from a variety of the industry leading vendors such as Identix Cogent Bioscrypt Motorola and NEC However the Identix algorithm is the only algorithm directly available from Datast...

Страница 13: ...ack 4 10 1 USB Ports There is one USB Host port and one USB client port on the mobile terminal that are accessible under the rubber I O port cover These are USB 2 0 High Speed 480 Mbps ports however t...

Страница 14: ...rt ISO 14443 smart card media Either antenna can be used to read these smart card media however the upper antenna is typically more convenient Place and hold the media to be read against the back of t...

Страница 15: ...to suit your personnel preferences the following options are available Calibration If your device is not responding properly to your screen taps you may need to recalibrate your screen Go to the Contr...

Страница 16: ...ake up the unit to a fully on condition Suspend This state is entered when no major background software tasks are running and the touch screen or function keys have not been used for some user configu...

Страница 17: ...Very Low This warning will repeat itself periodically until the condition clears or the unit automatically shuts down An error beep sounds when the battery charge level is critical 5 5 Creating Deskt...

Страница 18: ...inal type DSVII SC DSVII SW DSVII PA DSV3 SP or DSV3 EP and writes the appropriate platform type information into the registry along with the other registration information 6 3 DsVerify Registry Saver...

Страница 19: ...rint sensor Once complete a green window with a number 1 should appear to indicate the sensor was successfully calibrated Double tap the DsVerifyFpCaptureTest application Look in the lower right hand...

Страница 20: ...dating the smartcard firmware is as follows In the directory My Device Hard Disk DSV3 folder run the utility DsVerifyCleanUp and select the option Clear SCM Firmware Answer OK to the question Are you...

Страница 21: ...rs the reason for the failure is provided With all updates with the exception of the Embedded Controller the user is then placed back to the main screen of the app 4 update buttons The user may then u...

Страница 22: ...ification ISO 14443 A B Operating Frequency 13 56 MHz Optical Scanner Scan Area 124 W x 42 H mm 4 88 W x 1 65 H in Standard Symbologies OCR OCR B 2D Codes PDF417 1D Codes Code 39 Code 93 Code 128 UPC...

Страница 23: ...ions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interferenc...

Страница 24: ...was stored on the document the application will also perform a one to one match of a fingerprint stored on the document to the fingerprint captured by the on board fingerprint sensor This demonstrates...

Страница 25: ...he fingerprints Typical threshold values are Cogent 1000 Identix Low 200 High Not used Clicking on the OK will save the settings and return the application to the Configuration screen Clicking on the...

Страница 26: ...d the settings are stored in the registry and restored the next time the application is run The Digital Still Camera settings include Setting Selections Available Description of Setting Brightness 2 0...

Страница 27: ...bed above and an automatic scanning mode that will retrigger again after a successful read was completed The operator can choose between different illumination sources by using the radio button at the...

Страница 28: ...key will toggle between manual scanning mode as described above and automatic scanning mode that will retrigger again after a successful read was completed 10 6 EPassport ICAO Viewer ICAO Viewer exe T...

Страница 29: ...until the machine readable zone is read first 10 6 3 ICAO Viewer Operation After opening the application follow the instructions in the dialog box at the bottom of the main screen and wait for the Sc...

Страница 30: ...cessful PA red PA failed PA orange PA not performed Audio Feedback Successful Passport Read Three beeps will be played consecutively upon the successful reading of the electronic content from the pres...

Страница 31: ...D 11 1 2 PC Configuration for USB 2 0 ActiveSync First Time Only Run the Datastrip_MT_USB Sync_Setup utility found on the User Manual CD After running the Sync setup you will be prompted to connect yo...

Страница 32: ...ted by an internationally recognized logo shown below printed on the front cover The smart card integrated circuit in an ePassport stores The biographical data visually displayed on the data page of t...

Страница 33: ...process Shown below are the typical motions for inserting and reading an ePassport The top sequence of photos shows the normal operation where the operator can continuously see the LCD screen and obse...

Страница 34: ...e The document or credential to be scanned should then be inserted in the document slot and held against the glass platen The optical symbology to be read and decoded should be facing the glass platen...

Страница 35: ...be in HID keyboard emulation mode with the default settings run DsCamerScannerHIDTest exe to verify this 12 3 2 2 Changing the Operating 12 3 2 3 Mode from HID Mode to Virtual Com Mode If the scanner...

Страница 36: ...hat is mounted to the bottom of the terminal The contact smart card peripheral reads ISO 7816 smart cards The docking interface is replicated on the bottom of the peripheral so that the terminal equip...

Страница 37: ...ional peripheral available for the DSV3 mobile terminals and can be adjusted to for each variant of the mobile terminal The docking station has the following attributes Wired I O Access Provides conve...

Страница 38: ...nstalled in the correct forward or rear position the adjustment plunger may be adjusted to accommodate any installed optional peripherals The height of the adjustment plunger can be adjusted by pullin...

Страница 39: ...up The battery may be completely discharged or may not be installed Open the battery access cover and verify that the battery is properly installed Use the external AC power adapter to operate the uni...

Страница 40: ...Shoulder Strap and D Ring Connection Points For applications that require over shoulder carrying of DSV3 devices Ergonomically curved and padded shoulder area featuring non slip material on one side...

Страница 41: ...trip for service upgrade or repairs please contact the tech support department by e mail or telephone An RMA will be issued and should be clearly marked on the outside of your shipping carton Please b...