Model K-415A
Page 2
CAUTION
Connect the K-415A to a suitable A/C source and each outlet on the K-415A to the devices to be
controlled.
The maximum current rating for all of the devices connected to the K-415A cannot add up to more than
15 amps in domestic NEMA applications, or 10 amps in International applications as determined by the
IEC connector and the line cord.
See the specifications for each version on the following page.
The K-415A provides 5 indicator lamps.
POWER : Indicates that A/C power is applied to the K-415A
CIRCUIT: (CKT) Indicates which of the four outlets is ON
SPECIFICATIONS
K-415A
MAIN POWER INPUT: Standard NEMA 5-15 Plug on 6 foot 14/3 line cord - 120VAC
OUTPUT CIRCUITS: Standard NEMA 5-15 Receptacle
CURRENT MAXIMUMS: 15 Amps per Receptacle
15 Amps combined total of all receptacles
K-41OA-IEC
MAIN POWER INPUT: IEC 320 Male Connector – 220 -230 VAC
OUTPUT CIRCUITS: IEC 320 Receptacle
CURRENT MAXIMUMS: 10 Amps per Receptacle
10 Amps combined total of all receptacles
PHYSICAL: 1.75 H, 8.75 D 19.0 EIA Rack mount (inches)
Weight:
`
K-415A Rear View - Standard NEMA Version
1
2
3
4
CONTROL
15A Fuse
CONTROL WIRING:
9 pin female d-subminiature
Contact Closure between Control to Com = Power OFF
CONTROL # PIN # FEEDBACK# PIN #
1 1 1 6
2 2 2 7
3 3 3 8
4 4 4 9
COM 5 COM 5