12.  Modem Certifications 

 
The following countries have certified the internal modem.  In order to comply with local regulations, the 
countrycode must be set to the country of installation.  To set the modem for the desired country use the CLI 
command 

set modem countrycode <countrycode>.  

Use the 

get modem

 command to display the current country setting.   

 

Note:  Use of the wrong countrycode violates local laws and the warranty of this product. 

 
 

Country 

countrycode 

 

Country 

countrycode 

Argentina  

07 

 

Latvia 

253 

Australia  

09  

 

Liechtenstein  

253 

Austria  

253 

 

Lithuania 

253 

Belgium  

253 

 

Luxembourg  

253 

Brazil 

22 

 

Malaysia 

108 

Bulgaria 

253 

 

Malta 

253 

Canada  

181 

 

Mexico  

181 

Chile 

153 

 

Netherlands  

253 

China  

181 

 

New Zealand  

126 

Cyprus  

253 

 

Norway  

253 

Czech 
Republic  

253 

 

Philippines  

181 

Denmark  

253 

 

Poland 

253 

Estonia 

253 

 

Portugal  

253 

Finland  

253 

 

Russia 

253 

France  

253 

 

Singapore 

156 

Germany  

253 

 

Slovak 
Republic  

253 

Greece  

253 

 

Slovenia 

253 

Hong Kong  

153 

 

South Africa 

159 

Hungary  

253 

 

Spain  

253 

Iceland  

253 

 

Sweden  

253 

India 

153 

 

Switzerland  

253 

Indonesia  

153 

 

Taiwan  

254 

Ireland  

253 

 

Thailand 

181 

Israel 

181 

 

Turkey 

253 

Italy  

253 

 

United 
Kingdom  

253 

Japan  

00 

 

United States  

181 

Korea  

181 

 

 

 

 

Содержание iBootBar iBB-DC8

Страница 1: ...ut voltage on eight independent relay switches Remote control of each relay switch is via web browser RS 232 serial Telnet SNMP The Internal Modem Version model iBB 8DC M also supports dial up control...

Страница 2: ...8 7 Network Commands 19 8 8 Web Server Commands 20 8 9 Telnet Commands 20 8 10 Autoping Commands 21 8 11 Event Commands 21 8 12 Email Commands 22 8 13 Time Commands 23 8 14 Firmware Upload Commands 23...

Страница 3: ...the grounding type plug Do not use a 3 to 2 prong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to res...

Страница 4: ...k Start Defaults IP address 192 168 0 254 User Credentials Username admin Password admin Command Line Quick Start To view outlet status iBootBar get outlets To turn on off outlet 1 iBootBar set outlet...

Страница 5: ...d continuously receives status information from the rest of the iBootBars in the cluster Up to 128 outlets can be controlled in this manner from one IP address Grouping of outlets for simultaneous man...

Страница 6: ...l Page 6 Syslog reporting All activity can be reported to a syslog compatible server SSL Security Web server is secured with Secure Sockets Layer SSL encryption Certificate Utility Create Manage and U...

Страница 7: ...use in 36 countries See Appendix for complete modem certifications In models without the modem this jack is not used 6 4 Expansion The dual Expansion ports allow multiple iBootBars to be linked toget...

Страница 8: ...hange management 6 Clone saved configurations for replication of similar configurations in multiple iBootBars 7 Upload modified configurations to iBootBars 8 Control Power Outlets on one or more iBoot...

Страница 9: ...tax is found on page 16 7 3 Setting the IP Address iBootBars comes with factory default IP address 192 168 0 254 There are three techniques to setting the IP address of the iBootBar 1 Terminal Client...

Страница 10: ...ing ARP the hardware MAC address must be known This address is located on the bottom of the unit The syntax for the MAC address is nn nn nn nn nn nn 7 3 3 Windows 98 and Later 1 Access the iBootBar CL...

Страница 11: ...V180808N iBB DC8 Manual Page 11 7 4 Other Configuration Settings All parameters are set using the CLI See Page 16 for a complete list...

Страница 12: ...one of the two dropdown lists To select the global view click on Global To see the status of the AutoPing feature click on AutoPing Control The Control panel provides the clickable buttons to change...

Страница 13: ...w current alarms are highlighted in yellow 8 1 2 Group View The Group Veiw displays the status of a single group Groups are two or more outlets linked together for simultaneous control In the group vi...

Страница 14: ...rent status of the AutoPing The numeric column will display the number of times the AutoPing has been triggered A numeric counter other than 0 with the status reporting OK indicates that there have be...

Страница 15: ...selected state The user must have rights to the selected outlet This command is for iBootBars not used in a cluster configuration If used in a cluster it is the same as device 1 No get device 1 16 de...

Страница 16: ...er in the root iBootBar s user table 20 character max Yes set user username device 1 16 devname all outlet 1 8 all yes no Sets the users right to the selected outlet on a specific device Yes No Rights...

Страница 17: ...e timeout 30 3600 disable Console can be set to automatically logout with no activity for 30 seconds to 1 hr in seconds or disabled Yes 120 set console baudrate 400 4800 9600 19200 38400 57600 115200...

Страница 18: ...s dashes or colons Yes set factory defaults Resets all parameters to their factory settings including the IP Address Only available on the serial port Confirmation is required Note This command can ta...

Страница 19: ...ecific outlet on a specific device from the selected group Yes ren group groupname newname Renames the selected group 20 characters max Yes del group groupname Deletes the selected group Yes 8 7 Netwo...

Страница 20: ...be recommends changing the web port on all iBootBars that are accessible from the internet Yes 80 set web ssl yes no Enable or disable the root iBootBars web server s SSL capabilities Yes No 8 9 Telne...

Страница 21: ...the number of failures the select autoping requires before it triggers its action Yes 3 set autoping 1 16 device name 1 16 outlet 1 8 Assign an AutoPing to either a device outlet or group Each AutoPin...

Страница 22: ...utlet that will be controlled on the local device Yes set event eventname control device 1 16 devname outlet 1 8 Assigns the event to either a device outlet or group Each event can be assigned to one...

Страница 23: ...the hour of the root iBootBar s RTC Only valid if NTS is disabled Yes set time minute 0 59 Sets the minute of the root iBootBar s RTC Only valid if NTS is disabled Yes set time day 1 31 Sets the day...

Страница 24: ...to reboot or power cycle the outlet for the time configured with the CLI command cycle time The new status of the outlet is stated If the key is used the iBootBar will also state begin to indicate th...

Страница 25: ...event assign the event to a specific outlet or group and then configure the initial occurrence of the event the action to be performed and the repeat frequency if desired To configure the timed events...

Страница 26: ...n the assigned outlet When the ping response returns iBootBar will power the off the outlet Off Latch Upon triggering iBootBar will power off the assigned outlet and remain so until changed via the we...

Страница 27: ...K OK iBootBar To configure the AutoPing use the following commands set autoping 1 16 ipaddress dotted decimal set autoping 1 16 action action set autoping 1 16 frequency 1 999 set autoping 1 16 count...

Страница 28: ...tall the certificate from the iBootBar This is done once for each browser on the PC and each iBootBar 2 Root Certificate Authority The Root Certificate Authority method pre installs the certificates r...

Страница 29: ...be turned on or off for that user set user name email email address 64 char max set user name sendmail yes no Emails generated by iBootBar will display the device outlet s command along with the user...

Страница 30: ...sysContact Truncated to 128 Char 5 RW DisplayString sysName Truncated to 128 Char 6 RW DisplayString sysLocation Truncated to 128 Char 7 RO INTEGER sysServices 9 8 Firmware Upgrades The iBootBar can...

Страница 31: ...ge management 6 Clone saved configurations for replication of similar configurations in multiple iBootBars 7 Upload modified configurations to iBootBars 8 Control Power Outlets on one or more iBootBar...

Страница 32: ...utputs Eight 2 Position Pluggable Screw Terminal Current Capacity 8 A Max at 5 30VDC Combined Total 5 A Max at 5 30 VDC per Outlet 10 2 Compliance CE Directives 89 336 EEC 92 31 EEC and 93 68 EEC EN 5...

Страница 33: ...es with Part 15 of the FCC rules Operation of this device is subject to the following conditions 1 This device may not cause harmful interference and 2 this device must accept any interference that ma...

Страница 34: ...countrycode Argentina 07 Latvia 253 Australia 09 Liechtenstein 253 Austria 253 Lithuania 253 Belgium 253 Luxembourg 253 Brazil 22 Malaysia 108 Bulgaria 253 Malta 253 Canada 181 Mexico 181 Chile 153 N...

Страница 35: ...y 1 RO Integer32 snmpManagerIndex 2 RW DisplayString snmpManagerIPAddress 3 RW INTEGER Enum snmpManagerEnable 3 TB outletTable 1 TE outletEntry 1 RO Integer32 outletIndex 2 RW OCTET STRING outletName...

Страница 36: ...anty is obtained by contacting your Authorized Dataprobe Reseller THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT MISUSE ABUSE OR NEGLECT SELLER MAKES NO EXPRESS WARRA...

Отзывы: