background image

 

 
 Pre-Compliance  v180808n 

iBoot-WiFi   

Page 4 

 

 

 

4. Hardware Installation 

4.1.  Orientation 

iBoot Plugs directly into a NEMA 5-15 outlet.  It provides a 
switched NEMA 5-15 receptacle.  Up to 12 Amps can be 
switched through the iBoot-WiFi.  See Specification for 
complete details. 
 
 
 
 
 
 
 
 

4.2.  LEDs 

     
 
 
 
 
 
 
 
 
 
 
 
 

4.3.  Switches 

 

WPS Pushbutton  

 

Push and Hold 7 sec. 

Initiate WiFi Protected Setup (WPS)  

Reset Pushbutton 

Momentary Press 

Restart  iBoot-WiFi (no effect on outlet) 

Press and Hold 10 Seconds 

Reset Factory Default 

 

4.4.  Power   

Connect the iBoot-WiFi to a grounded three prong outlet.    The maximum switching capacity of the iBoot-WiFi is 12 
Amps.  
 
 
 

 

 

Outlet LED 
Red

 

On  

Outlet Power On. 

On with momentary Off (1.2 /.1) 

Power On – Cycle in Progress 

Slow Flash (.5s) 

Reset to Factory Defaults in Progress 

Off with Momentary On (1.2 /.1) 

Power Off – Reboot in Progress 

Off 

Outlet Power Off 

Network LED 
Blue

 

On 

Network Connected 

On with momentary Off (1.2 /.1) 

Micro Access Point Only Mode 

Slow Flash (.5s) 

Network Connection in Progress 

Fast Flash (.1s) 

Network Connection Attempt  Failed 

Off 

Unit not receiving power 

Network LED

Outlet LED

WPS
Pushbutton

Reset
Pushbutton

Power Outlet

12 Amps Max

Figure 2 iBoot-WiFi Major Features

 

Содержание iBoot-WiFi

Страница 1: ...tulations on purchasing the best network controlled power switch available The iBoot WiFi provides you the ability to reboot crashed devices with the click of a mouse Be sure to read up on all the fea...

Страница 2: ...a 3 to 2 prong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to rest on the power cord Do not locate...

Страница 3: ...t devices like sirens lamps signage or control environmental system like heaters coolers pumps etc 3 2 Multiple Control Options In addition to the Web control capabilities iBoot WiFi features several...

Страница 4: ...4 Power Connect the iBoot WiFi to a grounded three prong outlet The maximum switching capacity of the iBoot WiFi is 12 Amps Outlet LED Red On Outlet Power On On with momentary Off 1 2 1 Power On Cycl...

Страница 5: ...rd is wifi admin Open browser to 192 168 10 1 Login to iBoot with user admin password admin Access WiFi Setup Page From Home page click Setup Then click Set WiFi Select desired network You may Click S...

Страница 6: ...e steady on If the process did not complete successfully the blue LED will flash rapidly To try again press the Reset button to reset the iBoot WiFi when the Blue light is stead initiate WPS again by...

Страница 7: ...e user is automatically logged out and the username and password will need to be entered again for access This is to prevent accidental lockout by leaving the user logged in As the iBoot WiFi allows o...

Страница 8: ...on 7 6 The Home page will also show the five most recent history events including the Outlet Action User and Time Date of each event The iBoot WiFi holds the last 32 events in memory The user can acce...

Страница 9: ...caution when disabling the timeout feature as it is possible to lock out other users by forgetting to logout Closing the browser will not log the user out and will lock out web access If you do becom...

Страница 10: ...to identify the port number when you enter iBoot s IP address into your browser If the new port is 8080 then use the address http 192 168 1 254 8080 Linkback URL This setting allows control of the ho...

Страница 11: ...rebooted but pings a remote host to test the communication channel Ideal for DSL Cable Modem Verification iBoot WiFi monitors network device and powers up alarm or redundant system when there is no re...

Страница 12: ...unter indicates the number of times the AutoPing action has been triggered A counter reset button is provided Note All of the AutoPing Settings require a reboot of the iBoot WiFi after clicking Save A...

Страница 13: ...words are used by iBoot In the Login Required mode The User Password allows access to the control of iBoot but not to the Setup functions Clicking on the Setup button allows the Administrator to log i...

Страница 14: ...full Terms of Service of the iBoot Cloud Service is available here While the Cloud Service is in Beta stage the firmware in the iBoot WiFi is fully tested and released by Dataprobe If you do not enab...

Страница 15: ...ices List all registered iBoot units ordered by their Name Click on any iBoot line to manage that unit Locations Group all iBoots by location Click on any location to display or hide all the iBoots at...

Страница 16: ...e Power f Assign Names and Locations You can establish multiple locations and assign each iBoot to a location You can also name each iBoot independently from the Device Name that is displayed on the i...

Страница 17: ...played Enter user or admin and press Enter The prompt will change to Password Enter the admin or user password and press Enter The prompt will change to iBoot This indicates successful login Enter com...

Страница 18: ...address as set dhcp mode allows DHCP server to assign address set ipaddress dotted decimal This command is used to set the iBoot WiFi s ip address Used only when IP Mode Static set subnet dotted deci...

Страница 19: ...ng relationship And or Or Single set autoping action none on latch on follow off latch off follow cycle This command is used to set the action that the iBoot WiFi will perform when the autoping trigge...

Страница 20: ...his command is used to set how often the scheduled action will repeat set event 1 8 mult 0 999 This command sets how often the event will repeat the number of increments as set by the command above be...

Страница 21: ...us of the Outlet The DxP Protocol as well as example code and scripts in a variety of languages are available at http dataprobe com support iboot wifi 11 Troubleshooting The iBoot WiFi has a recessed...

Страница 22: ...ity 12 A Max at 105 125 VAC 12 3 Compliance Safety Pending UL 60950 1 1st Edition 2007 10 31 CSA C22 2 No 60950 1 03 1st Edition 2006 07 Emissions Pending FCC Part 15 IECS 0003 Class B Device IECS RSS...

Страница 23: ...r this Warranty is obtained by contacting your Authorized Dataprobe Reseller THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT MISUSE ABUSE OR NEGLECT SELLER MAKES NO EX...

Отзывы: