13.  Technical Support and Warranty 

 
Dataprobe Technical Support is available 8:30AM to 5:30PM ET to assist you in the installation and operation of this 
product.  To obtain Technical Support call 201- 934-5111, or Email us at [email protected].  Please have the 
following information available when you call: 
 
• 

Model of Product 

 

 

• 

Lot and Version Numbers 

• 

Data of Purchase 

 

 

• 

Name of Seller (if other than Dataprobe) 

 

If you purchased this product through an Authorized Dataprobe Reseller, you should contact them first, as 
they may have information about the application that can more quickly answer your questions. 

 

13.1. WARRANTY 

 
Seller warrants this product, if used in accordance with all applicable instructions, to be free from original defects in 
material and workmanship for a period of One Year from the date of initial purchase.  If the product should prove 
defective within that period, Seller will repair or replace the product, at its sole discretion. 
 
Service under this Warranty is obtained by shipping the product (with all charges prepaid) to an authorized service 
center. Seller will pay return shipping charges.  Call Dataprobe Technical Service at (201) 934-5111 to receive a 
Return Materials Authorization (RMA) Number prior to sending any equipment back for repair.  Include all cables, 
power supplies and proof of purchase with shipment. 
 
THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT, 
MISUSE, ABUSE OR NEGLECT.  SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY 
EXPRESSLY SET FORTH HEREIN.  EXCEPT TO THE EXTENT PROHIBITED BY LAW, ALL IMPLIED 
WARRANTIES, INCLUDING ALL WARRANTIES OF MERCHANT ABILITY OR FITNESS FOR ANY PURPOSE ARE 
LIMITED TO THE WARRANTY PERIOD SET FORTH ABOVE; AND THIS WARRANTY EXPRESSLY EXCLUDES 
ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES. 
 
Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the 
exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to 
you.  This warranty gives you specific legal rights, and you may have other rights which vary from jurisdictions to 
jurisdiction. 
 
WARNING: The individual user should take care to determine prior to use whether this device is suitable, adequate or 
safe for the use intended.  Since individual applications are subject to great variation, the manufacturer makes no 
representation or warranty as to the suitability of fitness for any specific application. 
 
  Dataprobe 

Inc. 

 

Содержание iBoot-G2

Страница 1: ...ongratulations on purchasing the best network controlled power switch available The iBoot G2 provides you the ability to reboot crashed devices with the click of a mouse Be sure to read up on all the...

Страница 2: ...2 prong adapter at the receptacle use of this type adapter may result in risk of electrical shock and or damage to this product 9 Do not allow anything to rest on the power cord Do not locate this pro...

Страница 3: ...er down equipment when not needed for power savings and to save on wear and tear Power up alert devices like sirens lamps messages or control environmental system like heaters coolers pumps etc 3 2 Mu...

Страница 4: ...d uses an IEC320 receptacle and detachable power cord an IEC to IEC extension cord can be used The iBoot G2 can be connected to a power strip to allow simultaneous control of multiple devices Make sur...

Страница 5: ...nstalling the Wall Mounting Kit DIN Rail Mounting 1 Remove the four mounting screws from the underside of the unit Do not disassemble the unit 1 Install the Wall Mounting Kit as shown 2 Install the wa...

Страница 6: ...ed by the DHCP server on your network If the IP address was assigned by a DHCP server no changes to the IP Address are required The IP address field also indicates the port for web access that is used...

Страница 7: ...at address is assigned to the iBoot You can lock the iBoot G2 to the current address by selecting IP Mode Static without changing the addresses Set the IP Mode either by using the web setup page or vi...

Страница 8: ...to the iBoot G2 at a time To control the power click on the appropriate button During power cycling the Power Status bar will indicate the temporary status with a blue background Once the cycle is co...

Страница 9: ...e timeout feature When there is no activity for the set time in minutes the user is logged automatically logged out and the username and password will need to be entered again for access This is to pr...

Страница 10: ...set if using DHCP HTTP Port This setting is used to allow access to iBoot G2 on a port other than the Web standard Port 80 If the port is changed you will need to identify the port number when you en...

Страница 11: ...is installed with the device to be rebooted but pings a remote host to test the communication channel Ideal for DSL Cable Modem Verification iBoot G2 monitors network device and powers up alarm or red...

Страница 12: ...ed the status will change to FAIL The Fail Counter will indicate the number of times the failure has occurred and the Trigger Counter indicates the number of times the AutoPing action has been trigger...

Страница 13: ...he Googbye page is displayed with a link to re login 7 6 Passwords Two passwords are used by iBoot The User Password allows access to the control of iBoot but not to the Setup functions When this pass...

Страница 14: ...nge to iBoot This indicates successful login Enter commands as needed When done enter the logout command 8 2 iBoot G2 CLI Syntax Command Description Factory Default Control Commands These commands are...

Страница 15: ...n When set to 0 the Telnet server is disabled 23 set dxp port 0 65535 This command sets the port that the iBoot G2 s DxP protocol service listens for incoming connections on When set to 0 the Protocol...

Страница 16: ...On 5 Event Name mm dd yyyy hh mm Annually Power On 6 Event Name mm dd yyyy hh mm Annually Power On 7 Event Name mm dd yyyy hh mm Annually Power On 8 Event Name mm dd yyyy hh mm Annually Power On set t...

Страница 17: ...user is presented with Password This prompts the user to enter his password iBoot This is the prompt that will be displayed after the user has successfully logged in iBoot Reboot Required This is the...

Страница 18: ...re making changes to you iBoot G2 1 Insure that the Upgrade Enable checkbox is checked in the Network Setup web page of the iBoot G2 2 Run the Device Management Utility available at the link above If...

Страница 19: ...expected Use the pushbutton as follows Action Result Momentary Soft Reset Will not change outlet status 5 Seconds push Reset to Factory Defaults Hold the button in until the Outlet LED is blinking the...

Страница 20: ...105 125 VAC 10 A Max at 210 240 VAC 12 3 Compliance UL cUL UL60950 Listed I T E File No E225914 CE Directives 89 336 EEC 92 31 EEC and 93 68 EEC EN 60950 3rd Edition EN 55022 1998 Class B FCC Part 15...

Страница 21: ...at 201 934 5111 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shipment THIS WARRAN...

Отзывы: