background image

Model 4P-MAS-30

Page 2

OPERATION

The 4P-MAS is controlled principally through an ASCII terminal interface.  Access to this configuration
menu can be achieved either by: connecting via modem connected to the Master Port, or directly via
terminal (using a null cable) into the Master Port of the 4P-MAS.  See page 6 for installation details.

 

The default parameters are:    9600 bps 8 data 1 stop no parity

.

All of these parameters can be changed through the programming menu.

Auto Rate Detect:

   The 4P-MAS automatically determines the speed of the connection.  If the Login

Prompt does not appear, press the Enter Key  several times to enable the Auto Rate Detect.

Once connected to the 4P-MAS, the system sends a login prompt.

LOGIN >

Enter the Security Code.  

The Factory Default Security Code is:   TEST  

.  Please change this code

as soon as possible.  Remember your code.  When connecting through a modem, three incorrect
attempts to enter the security code will cause the 4P-MAS to terminate the call.  When the correct code
is entered, the Main Menu appears:

A) PORT A

B) PORT B

C)  PORT C

D)  PORT D

1) LOCAL CONFIGURATION

X) EXIT

ENTER PORT >

This allows selection of any port, Local Configuration to access the programming menu or terminate the
current session.   When Exit is selected, the 4P-MAS logs the user out and a new Login is required.

To select a port, enter the letter desired, followed by the Enter Key.  Once a port is selected, the
4P-MAS will clear the screen and generate the following message:

PORT A SELECTED

ENTER ESC{PASSWORD}ESC TO RETURN TO MENU

At this point the Master Port is connected through to the port selected.  The 4P-MAS is passive to the
messages sent between the Master Port and the port selected.  To terminate the session with the
current port and bring back the menu, enter the escape character plus the security code and another
escape character.  i.e.  

E

s

C

TEST

E

s

C

Содержание 4P-MAS

Страница 1: ...all 4P MAS parameters Lead Control This option allows any of the four ports can access the master port by raising its Request To Send RTS or Data Terminal Ready DTR control lead This capability is in...

Страница 2: ...emember your code When connecting through a modem three incorrect attempts to enter the security code will cause the 4P MAS to terminate the call When the correct code is entered the Main Menu appears...

Страница 3: ...s This allows changing of the screen labels for the ports A PORT A B PORT B C PORT C D PORT D X EXIT ENTER LABEL A D Enter the label to be changed The current label is displayed along with a prompt fo...

Страница 4: ...bits and 1 stop bit Set Lead Control ENTER Y N Enter Y to add RTS DTR Lead control to the 4P MAS This mode allows the RTS or DTR of Ports A through D to select the Master Port Change this setting to Y...

Страница 5: ...logged into the unit or Manual control is selected the RTS and DTR leads are ignored The Timeout feature if enabled continues to operate when Lead control selects a port Once a port is selected due t...

Страница 6: ...gh JP4 allows selection of RTS or DTR as the control lead used in the Code Lead Control mode To access these jumpers disconnect the power source and remove the top cover of the 4P MAS by loosening the...

Страница 7: ...in a separate document With the modem installed the Master Port RS 232 port can still be used With the Modular Adaptor removed an external modem or terminal with null cable can be directly connected t...

Страница 8: ...t 201 967 8788 to receive a Return Materials Authorization RMA Number prior to sending any equipment back for repair Include all cables power supplies and proof of purchase with shipment THIS WARRANTY...

Отзывы: