Firmware Upgrades
The VisionSC-SDI4 cards allow
firmware upgrades to be completed on site rather than returning the card
to Datapath. Whenever a firmware upgrade is performed, the SW2 on the
DIP switch must be set ON.
The DIP Switch can be located on the back of the VisionSC-SDI4 (See Fig. 6 ). To perform the upgrade,
follow the step-by-step instructions provided by the upgrade application. The VisionSC-SDI4 is shipped
with the SW2 switch set at ON, therefore no action should be necessary.
In the unlikely event that something goes wrong during the upgrade process (e.g. System power outage) it
is possible to revert to the factory settings by powering down the system, temporarily setting SW2 to the
OFF position then powering up the system. Once the system has rebooted, set the SW2 back to the ON
position (while the system is still powered up) and restart the firmware upgrade process.
It should be noted that the latest driver installation program includes an automatic firmware update, if
required. Therefore, prior to installing the application and driver, ensure that SW2 is set to ON.
11
Fig. 6
Содержание VisionSC-SDI4
Страница 1: ...User Guide Version 1 0 4 VisionSC SDI4 ...