8
Firmware Upgrades
All cards in the VisionLC range allow firmware upgrades to be completed on site rather than returning the card to Datapath.
Whenever a firmware upgrade is performed,
the
J4
Link
MUST BE FITTED
on the
card.
To perform the upgrade, follow the step-by-step instructions provided by the upgrade application.
In the unlikely event that something goes wrong during the upgrade process (e.g. System power outage) it is possible to revert
to the factory settings by powering down the system, temporarily removing the
J4
link then powering up the system with the
link removed. Once the system has rebooted, replace the
J4
link (whilst the system is powered up) and restart the firmware
upgrade process.
It should be noted that the latest driver installation program includes an automatic firmware update, if required. Therefore,
prior to installing the application and driver, ensure that
J4
link is fitted.