15
3.2
Media Sensor Adjustment
The Media Sensor needs to be positioned so that the printer can detect the
presence of media and the top-of-form (except for continuous stock, where the
TOF is set through programming; see Label Length, Section 4.1.2). To adjust:
å
With media loaded, as described in Section 3.1.1 or 3.1.2, turn the Media
Sensor Adjust Knob clockwise (outward) or counterclockwise (inward)
until the Sensor Eye Mark is positioned over the media according to the
table below.
If loading media, return to the media loading instructions.
Media Sensor Selection and Adjustment
Media Type
Sensor Eye Mark Position
Sensor Required
*
Die-cut
Near the middle of the label
Gap
Notched
Centered over the notch
Gap
Reflective
Centered over the black mark
Reflective
Continuous
Near the middle of the media
Continuous
*
See Section 4.1.2 for Sensor Type selection.
ã
Note: Changes to the start of print position can be made using the Print
Control / Row Adjust or Row Offset (see Section 4.1.3).