Appendix S – RFID Overview
302
Class Series 2 Programmer’s Manual
Example1: The following example encodes a HF tag, starting at block 001, with
“Datamax <CR> writes RFID best.” It includes a Byte Count Specifier (the portion in
bold), where 0024 equals a four-digit decimal data byte count and includes all bytes that
follow until the end of the data. Field termination is set by the byte count.
<STX>L
D11<CR>
2W1X0000000010000
0024
Datamax<CR>
writes RFID best<CR>
E
Example 2: The following format encodes a tag with EPC data “1122334455667788”
with byte count shown in bold. Note that the field data is entered as the hex value for
the ASCII character.
<STX>L
D11
2W1x0000000000000
0008
<0x11><0x22><0x33><0x44><0x55><0x66><0x77><0x88>
E
GEN2 Kill/Access Passwords
Gen2 tags are capable of storing a 4-byte kill password and a 4-byte access password. The
kill password is stored at address 0, word offset 0 and access password is stored at address
0, word offset 2. The default for these passwords is typically 0.
To write these to the tag it is necessary to store the desired password value in the printer
database:
To write the database for the kill password the command is
<STX>KcRIKnnnnnnnn
, where
nnnnnnnn
represents the 4-byte value in hexadecimal pairs; and,
To write the database for the access password the command is
<STX>KcRICnnnnnnnn
,
where
nnnnnnnn
represents the 4-byte value in hexadecimal pairs.
These can also be viewed or modified via the printer’s display under RFID OPTIONS / UHF
SETTINGS. If the stored value for either or both of these passwords is non-zero and a label
formatting command to write EPC data is issued, then these passwords will be written also.
GEN2 Lock States
Gen2 supports a lock state of permalock, pwd-lock or both for any of the data sections of
the tag. This includes access/kill passwords, EPC data, Tag ID or user memory. To store
these states in the printer database the command is
<STX>KcRIGn
, where: 1 is permalock; 2
is pwd-lock; 3 is both; and, 0 is none (default). When a section of the tag is written via
label formatting command and the stored lock state and lock after write are enabled, the
section will be locked.
Содержание A-Class
Страница 2: ......
Страница 4: ......
Страница 20: ...Overview 8 Class Series 2 Programmer s Manual ...
Страница 28: ...Immediate Command Functions 16 Class Series 2 Programmer s Manual ...
Страница 136: ...Extended System Level Command Functions 124 Class Series 2 Programmer s Manual ...
Страница 156: ...Label Formatting Command Functions 144 Class Series 2 Programmer s Manual ...
Страница 176: ...Generating Label Formats 164 Class Series 2 Programmer s Manual ...
Страница 188: ...Appendix B Sample Programs 176 Class Series 2 Programmer s Manual ...
Страница 196: ...Appendix D Reset Codes 184 Class Series 2 Programmer s Manual ...
Страница 208: ...Appendix E Single Byte Symbol Sets 196 Class Series 2 Programmer s Manual ...
Страница 260: ...Appendix G Bar Code Details 248 Class Series 2 Programmer s Manual ...
Страница 280: ...Appendix J General Purpose Input Output Port Applications 268 Class Series 2 Programmer s Manual ...
Страница 292: ...Appendix O UPC A and EAN 13 Variable Price Weight Bar Codes 280 Class Series 2 Programmer s Manual ...
Страница 304: ...Appendix Q Plug and Play IDs 292 Class Series 2 Programmer s Manual ...
Страница 308: ...Appendix R Line Mode 296 Class Series 2 Programmer s Manual ...
Страница 320: ...Appendix T WiFi Region Country Codes 308 Class Series 2 Programmer s Manual ...
Страница 324: ...Appendix U Display Icon Key and Control Panel Button Sequence Functions 312 Class Series 2 Programmer s Manual ...
Страница 330: ......