7
effected by means of electrically non-conductive material or
an isolated metal barrier.
Barbed wire or razor wire shall not be electrified by an
energizer.
A non-electrified fence incorporating barbed wire or razor
wire may be used to support one or more off-set electrified
wires of an electric animal fence. The supporting devices for
the electrified wires shall be constructed so as to ensure
that these wires are positioned at a minimum distance of
150 mm (6") from the vertical plane of the non-electrified
wires. The barbed wire and razor wire shall be earthed at
regular intervals.
Follow our recommendations regarding earthing.
A distance of at least 10 m (33') shall be maintained
between the energizer earth electrode and any other
earthing system connected parts such as the power supply
system protective earth or the telecommunication system
earth.
Connecting leads that are run inside buildings shall be
effectively insulated from the earthed structural parts of the