background image

PEN READER CONFIGURATION 

 
Read the RESTORE DEFAULT code, then read the PEN 
interface selection code. 

RESTORE DEFAULT 

iPk

 

iPk

 

iPk

 

 

PEN 

i$1#k

 

i$1#k

 

i$1#k

 

 

 

DEFAULT VALUES 

USB DEFAULT SETTINGS 

DATA FORMAT

: code identifier disabled, no field adjustment, 

code length not transmitted, character replacement disabled.

 

USB KEYBOARD

: USA keyboard, inter-character and inter-

code delays disabled, control character emulation = 
ctrl+shift+key; 

USB COM

: no handshaking, delay disabled, rx timeout 5 sec., 

ack/nack disabled, FIFO enabled, serial trigger lock disabled; 

Default Headers and Terminators for each USB mode: 

USB-KBD: no header, terminator = ENTER 

USB-KBD-ALT-MODE: no header, terminator = CR 

USB-COM: no header, terminator = CR-LF 

USB-IBM-TABLE TOP: not applicable 

USB-IBM-HAND HELD: not applicable

 

RS232 Standard DEFAULT SETTINGS 

9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, 
delay disabled, rx timeout 5 sec., ack/nack disabled, FIFO 
enabled, serial trigger lock disabled; 

DATA FORMAT

: code identifier disabled, no field adjustment, 

code length not transmitted, 

no header

terminator = CR-LF

character replacement disabled 

RS232 Nixdorf DEFAULT SETTINGS 

9600 baud, parity odd, 8 data bits, 1 stop bit, handshaking 
hardware (RTS/CTS), delay disabled, rx timeout 9.9 sec., 
ack/nack disabled, FIFO enabled, serial trigger lock disabled; 

DATA FORMAT

: code identifier enabled, no field adjustment, 

code length not transmitted, 

no header

terminator = CR

character replacement disabled 

 

WEDGE (continued)

 

IBM Terminals 31xx, 32xx, 34xx, 37xx: 

To select the interface for these IBM Terminals, read the 
correct KEY TRANSMISSION code. Select the 
KEYBOARD TYPE if necessary (default = advanced 
keyboard). 

KEY TRANSMISSION MODE

 

 make-only 

keyboard

 

i$1Pk

 

i$1Pk

 

i$1Pk

 

 make-break 

keyboard

 

i$1Ik

 

i$1Ik

 

i$1Ik

 

KEYBOARD TYPE

 

 advanced 

keyboard 

i',fk

 

i',fk

 

i',fk

 

 typewriter 

keyboard 

i',ak

 

i',ak

 

i',ak

 

 

The following interface selection allows barcodes sent to 
the PC to be interpreted correctly independently from the 
Keyboard Nationality used. 

You do not need to make a 

Keyboard Nationality selection. 

(default = Num Lock Unchanged) 

Make sure the Num Lock key on your keyboard is ON. 

 

IBM AT - ALT mode 

i$1k

 

i$1k

 

i$1k

 

 

PC Notebook - ALT mode 

i$1k

 

i$1k

 

i$1k

 

Содержание Touch 65 pro

Страница 1: ...Touch 65 90 CONTACT READERS QUICK REFERENCE 820001400...

Страница 2: ...garsi a www datalogic com services support F La version fran aise de ce manuel est disponible sur Internet Cliquez sur www datalogic com services support D Im Internet finden sie die deutschsprachige...

Страница 3: ...s like a model without trigger Code scanning is performed along an imaginary line passing across the reading window This imaginary line must pass through the entire code Successful scanning is obtaine...

Страница 4: ...dments et ses successifs amendements und sp teren Ab nderungen y succesivas enmiendas Basate sulle legislazioni degli Stati membri in relazione alla compatibilit elettromagnetica ed alla sicurezza dei...

Страница 5: ...y with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operat...

Страница 6: ...First Start Up Connect Touch to Host Select desired USB interface code USB KBD is default Read test codes Reader is READY Load drivers if requested Load drivers if requested Successive start ups will...

Страница 7: ...mperature 0 C to 55 C Storage Temperature 20 C to 70 C Humidity 90 non condensing Drop Resistance 1 2 m ESD Protection 16 KV Protection Class IP30 Mechanical Features Weight without cable about 160 g...

Страница 8: ...i bk i bk i bk Svenskt i k i k i k OPERATING TEST Read the TEST codes below EAN 8 1234 5670 EAN 13 1 234567 000992 Code 39 Normal 1 7 1 6 2 Code 128 t e s t Interleaved 2 of 5 0 1 2 3 4 5 6 7 8 4 YOUR...

Страница 9: ...elta IBM Code 11 Code 16K Code 49 RSS Codes TRIGGER SELECTION After configuring the reader interface type the software trigger parameter can be selected so that the reader operates like a model withou...

Страница 10: ...enabled no field adjustment code length not transmitted no header terminator CR character replacement disabled WEDGE DEFAULT SETTINGS USA keyboard caps lock off caps lock auto recognition enabled num...

Страница 11: ...no field adjustment code length not transmitted no header terminator CR LF character replacement disabled RS232 Nixdorf DEFAULT SETTINGS 9600 baud parity odd 8 data bits 1 stop bit handshaking hardwa...

Страница 12: ...k i 1 Vk APPLE APPLE ADB Bus i 1 k i 1 k i 1 k WEDGE KEYBOARD NATIONALITY Wedge users should select one of the following WEDGE KEYBOARD NATIONALITY codes Belge i k i k i k Deutsch i k i k i k English...

Страница 13: ...k i 1 Vk APPLE APPLE ADB Bus i 1 k i 1 k i 1 k WEDGE KEYBOARD NATIONALITY Wedge users should select one of the following WEDGE KEYBOARD NATIONALITY codes Belge i k i k i k Deutsch i k i k i k English...

Страница 14: ...no field adjustment code length not transmitted no header terminator CR LF character replacement disabled RS232 Nixdorf DEFAULT SETTINGS 9600 baud parity odd 8 data bits 1 stop bit handshaking hardwa...

Страница 15: ...enabled no field adjustment code length not transmitted no header terminator CR character replacement disabled WEDGE DEFAULT SETTINGS USA keyboard caps lock off caps lock auto recognition enabled num...

Страница 16: ...elta IBM Code 11 Code 16K Code 49 RSS Codes TRIGGER SELECTION After configuring the reader interface type the software trigger parameter can be selected so that the reader operates like a model withou...

Страница 17: ...i bk i bk i bk Svenskt i k i k i k OPERATING TEST Read the TEST codes below EAN 8 1234 5670 EAN 13 1 234567 000992 Code 39 Normal 1 7 1 6 2 Code 128 t e s t Interleaved 2 of 5 0 1 2 3 4 5 6 7 8 4 YOUR...

Страница 18: ...mperature 0 C to 55 C Storage Temperature 20 C to 70 C Humidity 90 non condensing Drop Resistance 1 2 m ESD Protection 16 KV Protection Class IP30 Mechanical Features Weight without cable about 160 g...

Страница 19: ...First Start Up Connect Touch to Host Select desired USB interface code USB KBD is default Read test codes Reader is READY Load drivers if requested Load drivers if requested Successive start ups will...

Страница 20: ...y with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operat...

Страница 21: ...dments et ses successifs amendements und sp teren Ab nderungen y succesivas enmiendas Basate sulle legislazioni degli Stati membri in relazione alla compatibilit elettromagnetica ed alla sicurezza dei...

Отзывы: