SOFTWARE CONFIGURATION
53
6
Backup Procedure
1. Make sure the Write Protection switch (inside the CBX500 ATS) on the BM100 is unlocked.
2. While VisiSet™ is connected to the Master reader, select the Backup item from the
Device Menu in confirm by clicking the
Yes
button.
3. During the procedure, messages appear on the VisiSet™ terminal window showing the
progress and at the end the final results.
4. Set the Write Protection switch on the BM100 to locked.
Restore Procedure
1. While VisiSet™ is connected to the Master reader, select the Restore item from the
Device Menu in confirm by clicking the
Yes
button.
2. During the procedure, messages appear on the VisiSet™ terminal window showing the
progress and at the end the final results.
Backup Files to PC
VisiSet™ also allows Backup to be performed through the ID-NET™ network to .ini files,
saving them to the local PC. See the VisiSet™ Help On Line file under "ID-NET™ Backup to
File Through Master" for details on this procedure.
6.2.2 Using CBX500 ATS HMI Interface (Keypad/Display)
Up Enter Down
Figure 21 – CBX500 ATS Keypad
Through the CBX500 ATS keypad and display, you can perform the Backup and Restore
functions from the "Extended" menu. See chapter 4 for details on entering the Extended menu.
Backup Procedure
1. Make sure the Write Protection switch (inside the CBX500 ATS) on the BM100 is unlocked.
2. Select the Backup item from the Extended menu and press the Enter key on the
Yes
item.
3. When the procedure is complete a message appears on the display showing the results
(
Done
or
Error
).
4. Set the Write Protection switch to locked.
Restore Procedure
1. Select the Restore item from the Extended menu and press the Enter key on the
Yes
item.
2. When the procedure is complete a message appears on the display showing the results
(
Done
or
Error
).