   SG4 EXTENDED

SAFETY INFORMATION

The stopping system of the machine must be electrically controlled.

This control system must be able to stop the dangerous movement of the machine within the total machine 
stopping time T as per paragraph “Minimum installation distance” of the Instruction Manual and during all 
working cycle phases.

Mounting and connection of the safety light curtain must be carried out by qualified personnel only, according 
to the indications included in the Instruction Manual (refer to paragraphs “Installation”, “Mechanical Mount-
ing”, “Electrical Connections”, “Alignment Procedure”) and in the applicable standards.

The safety light curtain must be securely placed in a particular position so that access to the dangerous zone is 
not possible without the interruption of the beams (refer to paragraph “Installation” in the Instruction Man-
ual).

The personnel operating in the dangerous area must be well trained and must have adequate knowledge of all 
the operating procedures of the safety light curtain.

The TEST, RESET/RESTART and OVERRIDE buttons must be located outside the protected area because the 
operator must check the protected area during all Test, Restart and Override operations.

NOTE

Precautions to be observed for the choice and installation

The outputs (OSSD) of the ESPE must be used as machine stopping devices and not as command devices.

The machine must have its own START command.

The dimension of the smallest object to be detected must be larger than the resolution level of the device.

The ESPE must be installed in an environment complying with the characteristics indicated in chapter “Techni-
cal data” of the Instruction Manual.

The ESPE must not be installed close to strong and/or flashing light sources, in particular close to the front win-
dow of receiving unit.

The presence of intense electromagnetic disturbances could affect device’s correct operation. This condition 
shall be carefully assessed with the advice of DATALOGIC Technical Service.

The operating distance of the device can be reduced in presence of smog, fog or airborne dust.

A sudden change in environment temperature, with very low minimum peaks, can generate a small condensa-
tion layer on the lenses and thus jeopardize correct operation.

Reflecting surfaces near the safety light curtain light beam (above, under or lateral) can cause passive reflec-
tions that can jeopardize functioning.

The safety device must be installed at a distance that is greater or equal to the minimum safety distance S to 
ensure that the operator cannot reach the dangerous area until the moving dangerous object has been 
blocked by the ESPE

.

CAUTION

The following points must be observed for a correct and safe use of the safety light curtains of 
the SG4-Extended series.

Please carefully read the instructions for the correct functioning before powering the light cur-
tain on.

CAUTION

Make sure that the protection level assured by the device is compatible with the real danger 
level of the machine to be controlled, according to EN ISO 13849-1 or EN 62061.

CAUTION

The failure to respect the safety distance reduces or cancels the ESPE protection function. For 
more detailed information about calculation of safety distance, please refer to the Instruction 
Manual.

Содержание SG4 Extended

Страница 1: ...G4 family name then select your product from the dropdown list Click on the Manuals Technical Literature link to download your Instruction Manual The Instruction Manual must be available at all times when installing and working with the product Scan or tap on the QR code to download the Instruction Manual SG4 Extended Series SG4 N Models QUICK REFERENCE GUIDE Safety Light Curtains with infrared be...

Страница 2: ...ESPE must be installed in an environment complying with the characteristics indicated in chapter Techni cal data of the Instruction Manual The ESPE must not be installed close to strong and or flashing light sources in particular close to the front win dow of receiving unit The presence of intense electromagnetic disturbances could affect device s correct operation This condition shall be carefull...

Страница 3: ...M12 8 poles M12 5 poles SG4 N RX 1 White RESTART RESET EDM OVERRIDE 2 Brown 24 VDC 3 Green MUTING 1 4 Yellow MUTING 2 5 Gray OSSD1 6 Pink OSSD2 7 Blue 0 V 8 Red MUTING LAMP SG4 N TX 1 Brown 24 V 2 White TEST 3 Blue 0 V 4 Black EARTH 5 N C ...

Страница 4: ...dition shows the effective alignment of the first synchronisation beam B Rotate the emitter pivoting on the lower optics axis until the yellow SYNC 2 LED is OFF C Delimit the area in which alignment is good and steady through some micro adjustments for the first and then for the second unit so to have the maximum alignment LEVEL and then place both units in the center of this area D Fix the two un...

Страница 5: ...ial Muting 2 Zone A Zone A B Zone A B C Muting Exit Delay 3 ON OFF EDM 4 Enabled Disabled Restart Mode 5 Auto Manual Muting Direction 6 T bidirectional L monodirectional Muting Timeout 7 10 min Inf Muting Filter 8 ON OFF CAUTION The device can enter Basic Configuration during Normal Operation As soon as CONFIRM action after configuration is executed the device automatically restarts in Normal Oper...

Страница 6: ...or persists contact Datalogic Technical Support FAILURE LOCKOUT Failure on EDM Check EDM feedback line and EDM configu ration Activate RESET line FAILURE LOCKOUT Failure on restart Check RESTART line connection Activate RESET line FAILURE LOCKOUT BCM configuration failure Re operate Basic Configuration If error per sists contact Datalogic Technical Support CRITICAL FAILURE LOCKOUT Generic non rese...

Страница 7: ... LOCKOUT Failure on optics Activate RESET line If error persists contact Datalogic Technical Support FAILURE LOCKOUT BCM Configuration failure Re operate Basic Configuration If error per sists contact Datalogic Technical Support CRITICAL FAILURE LOCKOUT Generic non resetta ble failure Turn ON OFF ESPE Shown Failure Code cor responds to failures above with steady LEDs ESPE WORKING MODE INDICATION L...

Страница 8: ...nts of the standards listed in the Declaration of Conformity Datalogic products are mainly designed for integration purposes into more complex systems For this rea son it is under the responsibility of the system integrator to do a new risk assessment regarding the final installation Warning This is a Class A product In a domestic environment this product may cause radio interference in which case...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ...right no part of this documentation may be repro duced stored in or introduced into a retrieval system or transmitted in any form or by any means or for any purpose without the express written permission of Data logic S p A and or its affiliates Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S and the E U www datalogic com 821005603 ...