SG2 MUTING
34/96
6 FUNCTIONS SETTING
ESPE operation functions and parameters configuration can be performed by means of push-buttons; this setting
lets the user select among basic functions / basic parameters with the help of push buttons and led user interface
(available on both RX and TX unit)
Basic configuration mode:
A user interface of 8 leds and 3 protected push buttons lets the user operate basic configuration. Leds are the
same used for user interface in normal operation.
The user must use the provided special tool (see cfr.
INCLUDED ACCESSORIES page 63
) to activate push
buttons thus accidental access to safety configuration is avoided.
Fig 37 - User interface
Basic configuration steps:
In the right side of user control panel (on both units of the light curtain) a setting interface composed by 3 push
buttons is present; the purpose of the interface is to let the user set light curtain locally.
Setting interface is composed by a CONFIRM push button used to enter in BCM and to confirm the selected
configuration, a SELECT push button used to roll by different functions and an ENABLE push button to
activate/deactivate the current function.
Here below the necessary steps for BCM configuration:
Keep CONFIRM button pressed to enter Basic Configuration Mode
A Test Pattern is shown on led interface;
carefully check that ALL LED are lit in sequence from 2 to 8,
then
current configuration is shown
Choose function to set by SELECT button; selected led blinks
Configure selected function with ENABLE button (switch led on/off)
Repeat steps 3 and 4 until desired configuration is visualized
Keep CONFIRM button pressed to authorize the new configuration
Содержание SG2 BASE Series
Страница 1: ......
Страница 3: ......
Страница 83: ...SG2 MUTING 83 96 Fig 113 Light curtain Active Passive arms L Fig 114 Light curtain Active Passive arms T ...
Страница 96: ...SG2 MUTING 96 96 ...