SG-BWS-T4
4
Further to the 7-segment display (for diagnostics purposes) the warning components include 3 LEDs:
LED
Indication
POWER
Device is powered correctly
NORMAL
Safety outputs closed
SAFE
Safety outputs open
Tab. 2 Signalling LEDs
2.3.
Safety sensors
4 types of photocells can be connected to the safety control unit:
S5-5-X-X-SG-ST2: Type 2 safety photocell emitting infrared beams.
S5-5-X-X-SG-ST4: Type 4 safety photocell emitting infrared beams.
SL5-5-X-X-SG-ST4: Type 4 safety photocell emitting long-distance red laser beam.
S300-5-X-X-ST4: Type 4 safety photocell for long-distance applications.
See section 10 “Order data” for further details about available photocell models.
Using the above photocells independently from SG-BWS-T4 does not meet EN
61496-1 and CLC/TS 61496-2 requirements and is thus not allowed.
Connection of Type 2 photocells results in the whole system category downgrade
to Type 2.
S5 and SL5 sensors are housed in plastic tube casings featuring M18x1 thread.
Fig. 2 Safety single beam photocells S5,SL5 series (appearance)
The photocells are equipped with LEDs for operation status indication:
Sensor
LED
Indication
S5/SL5/S300 Emitter
Green
Sensor correctly powered
S5 Receiver
Green
Sensor correctly powered
/
Green
Poor/insufficient signal received
Red
Output active
Red
Output not active
SL5/S300 Receiver
Green
Sensor correctly powered
/
Green
Poor/insufficient signal received
Yellow
Output active
Yellow
Output not active
Tab. 3 Photocells signalling
Please refer to the relevant user manual for further details about photocells operation.