TOP PANEL INTERFACE

 

Opening the dust cover provides access to the top panel interface. The top panel interface consists of the RUN/PRG/ADJ mode 
switch, LO/DO switch, +/SET/- Navigation key, dual red/green digital displays, and output LED. 

 

RUN/PRG/ADJ Mode Switch

 

 

The RUN/PRG/ADJ mode switch puts the sensor in RUN, PRG (Program), or ADJ (Adjust) mode. 
RUN mode allows the sensor to operate normally and prevents unintentional programming changes via the 
+/SET/- button. PRG mode allows the sensor to be programmed through the display driven programming 
menu (see 

Program Mode 

below). 

ADJ mode allows the user to perform Expert TEACH/SET methods and Manual Adjust (see 

Adjust Mode 

below). 

 

CH1/CH2 Switch

 

 

The CH1/CH2 switch selects which output's parameters can be accessed and changed in the interface of the 
display. 

  CH1 selects the Analogue Output 

  CH2 selects the Discrete Output 

 

+/SET/- Navigation key

 

 

The +/SET/- Navigation key is a 3-way button. The +/- positions are engaged by rocking the button left/ right. 
The SET position is engaged by clicking down the button while the rocker is in the middle position.  
All three button positions are used during PRG mode to navigate the display driven programming menu. 
During ADJ mode, SET is used to perform TEACH/SET methods and +/- are used to manually adjust the 
threshold(s). The Navigation key is disabled during RUN mode, except when using Window SET (see 

Window SET)

.

 

 

Red/Green Digital Displays

 

 

During RUN and ADJ mode, the Red display shows the signal level and the Green display shows the 
threshold. 
During PRG mode, both displays are used to navigate the display driven programming menu. 

 

               

Dual Output LED

 

The output LED provides a visible indication when the output is activated. 

  1 represents the Channel 1 analogue output. When on, it indicates that the signal is within the 

analogue range. 

  2 represents the Channel 2 discrete output. When on, it indicates that the output is conducting. 

 

 
 
 
 
 

Teach / Set methods

 

For more information about how to perform TEACH/SET methods, see the www.datalogic.com. 

 
 

 

Run Mode

 

Run mode allows the sensor to operate normally and prevents unintentional programming changes. 
In CH1 RUN mode, the +/SET/- Navigation key is used to view the analogue endpoints and midpoint signal values. 
The +/SET/- Navigation key is disabled during CH2 RUN mode, except when using Window SET (see 

Window SET

). 

 

 

Содержание S70

Страница 1: ...onnected to a terminal block 1 Analogue and Discrete Output LEDs 2 CH1 CH2 Switch 3 RUN PRG ADJ Mode Switch 4 Lever Action Fiber Clamp 5 Red Signal Level 6 Green CH1 Analog Output Signal or CH2 Thresh...

Страница 2: ...these steps to install glass or plastic fibers 1 Open the dust cover 2 Move the fiber clamp forward to unlock it 3 Insert the fiber s into the fiber port s until they stop 4 Move the fiber clamp backw...

Страница 3: ...is in the middle position All three button positions are used during PRG mode to navigate the display driven programming menu During ADJ mode SET is used to perform TEACH SET methods and are used to...

Страница 4: ...s the following settings to be programmed in the S70 CH1 Analog Factory Default Settings Press and hold SET to exit choice list without saving 4 NOTE The CH1 settings programmed for rESP SPd inPt SEL...

Страница 5: ...ted in Program mode the settings below can be configured for CH2 discrete output and are independent from CH1 settings CH2 Discrete Factory Default Settings Press and hold SET to exit choice list with...

Страница 6: ...on to 5 V 20 mA The order of the taught points determines the slope If the first taught condition is darker the slope will be positive If the first taught condition is lighter the slope will be negati...

Страница 7: ...threshold at the optimum level see Fig 3 Dynamic TEACH Light Operate shown Reverse the CH2 Output ON and OFF conditions by using the LO DO Light Operate Dark Operate selection through the program int...

Страница 8: ...tate Threshold can be adjusted using and Navigation key Manual Adjust Recommended for applications where only one condition is known for example a stable dark background with varying lighter targets S...

Страница 9: ...at 30 VDC ON state saturation voltage NPN 1 5 V PNP 2 V Analogue Output Recovery Time 2 the selected response speed Analogue Output Ripple Content p p 0 5 of the full scale analogue output Analogue O...