background image

 

 
 

 

S62-PL…M Laser 

Background suppression

 

 

INSTRUCTION MANUAL 

 
 
 
 
 
 
 
 
 

CONTROLS 

OUTPUT LED (yellow) 

The yellow LED ON indicates the output status: N.O. closed and N.C. open. 

 

POWER ON LED (green) 

The green LED ON indicates the sensor powering status and laser emission 
presence. 

 

DISTANCE ADJUSTMENT TRIMMER (ADJ.) 

The multiturn trimmer with clutch (6 turn) adjusts the suppression distance 
through the mechanical variation of the optic triangulation angle. 
The operating distance increases rotation the trimmer shaft in a clockwise 
direction. 
Please refer to “SETTING” paragraph for the correct use procedure. 

 

POSITION INDICATOR 

This indicator has a scale numbered from 1 to 6 that allows the precise 
adjustment of the suppression distance on the entire operating range. 
Please refer to “SETTING” paragraph for the correct use procedure. 
 
 

INSTALLATION 

The sensor can be positioned by means 
of the three housing’s holes using two 
screws (M4x25 or longer, 1.5 Nm 
maximum tightening torque) with 
washers. 
Various orientable fixing brackets to 
ease the sensor positioning are 
available (please refer to the 
accessories listed in the general 
catalogue). 
The operating distance is measured from the front surface of the sensor 
optics. 
The M12 connector can be oriented at two different positions using the 
specific fastening spring and rotating the block to 180°. 
 

CONNECTIONS 

M12 connector 
 
 

 

 

 

TECHNICAL DATA 

 

S62-PL-M01…

S62-PL-M11…

Power supply: 

10 … 30 VDC 

Ripple: 

2 Vpp max. 

Consumption 
(output current excluded): 

30 mA max 

Outputs: 

PNP or NPN N.O. / N.C.; 30 VDC max. (short-circuit protection) 

Output current: 

100 mA (overload and overvoltage protection) 

Output saturation voltage: 

 2 V 

Response time: 

140 

s 200 

Switching frequency: 

3.5 kHz 

2.5 kHz 

Emission type: 

RED LASER (

 = 645…665nm): Class 1 EN 60825-1 (2014), Class II CDRH 21 CFR PART 1040.10 

Pulsed emission: pot. max 

 5mW; pulse duration = 5

s; frequency = 14KHz (mod. M01) / 10KHz (mod. M11) 

Focalisation point : 

60 mm 

150 mm 

Spot dimension: 

< 0.2 mm (at 60 mm) 

< 0.4 mm (at 150 mm) 

Operating distance (typical values): 

30…150 mm 

50…350 mm 

Adjustment: 

4-turn distance adjustment trimmer 

6-turn distance adjustment trimmer 

Difference (90% white/ 4% black): 

< 4 % (see DETECTION DIAGRAM) 

Hysteresis (90% white): 

< 1 % 

Indicators: 

OUTPUT LED (YELLOW) / POWER ON LED (GREEN) 

Functioning temperature: 

-10 … 55 °C 

Storage temperature: 

-20 … 70 °C 

Dielectric strength: 

500 Vac 1 min., between electronics and housing 

Insulating resistance: 

>20 M

 500 Vdc, between electronics and housing 

Ambient light rejection: 

According to EN 60947-5-2 

Vibrations: 

0.5 mm amplitude, 10 … 55 Hz frequency, for each axis (EN60068-2-6) 

Shock resistance: 

11 ms (30 G) 6 shock for each axis (EN60068-2-27) 

Housing material: 

ABS 

Lens material: 

PMMA window; PC lens 

Mechanical protection: 

IP67 

Connections: 

M12 4-pole connector 

Weight: 

40 g. max. 

SETTING 

Suppression distance setting 

 
1. 

Object detection

 

Position object to detect in front of the sensor at the distance required. 
Turn distance adjustment trimmer (ADJ) to minimum: yellow LED OFF and 
green LED ON. 
 

 

 

Rotate trimmer in a clockwise direction until the yellow LED and green LED 
turn ON. 

Object detection condition

 (A status of position indicator).

 

 

 

 

  

A

 

 

2. 

Background suppression

 

Remove object and ensure that the background is in front of the sensor: 
yellow LED OFF and green LED ON. 
 

 

 

Rotate trimmer in a clockwise direction until the yellow LED and green LED 
turn ON: 

background detection condition 

(B status of position indicator).

 

 

 

 

  

 
The trimmer reaches maximum level with yellow LED OFF if the background 
is outside the operating range. 

 

Rotate trimmer in an anticlockwise direction until yellow LED turns OFF 
and green LED ON: 

condition where background is outside operating 

range 

(C status of position indicator). 

 

 

 

   

3. Setting and control 

Rotate trimmer in an anticlockwise direction until the indicator reaches 
an intermediate point between position A and C. 

 

 

 

If position A and C are close to each other, leave trimmer on position C. 
The sensor is now ready to function correctly and in stable conditions.

 

 

 

DETECTION DIAGRAM

 

 

 

DIMENSIONS 

4.7

mm

Ø15

16

M12

18

x45°

18

DISTANCE ADJUSTMENT TRIMMER

POSITION INDICATOR

2

0.75

50

42

18.4

POWER ON LED

OUTPUT LED

10.7

11

6.18

11

6

14

50

42

1.1

EMITTER

RECEIVER

18

.2

15.5

 

 

SAFETY PRECAUTIONS 

All the electric and mechanical safety regulations have to be respected during 
sensor functioning. 
The sensor has to be protected against mechanical damage. 
Apply the labels supplied in a visible position near the laser emission beam.

 

 
 
 
 

The sensors are NOT safety devices, and so MUST NOT be used in the safety control of the machines 

where installed. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Datalogic S.r.l. 

Via S. Vitalino 13 - 40012 Calderara di Reno - Italy 
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com

 

 
Helpful links at www.datalogic.com: 

Contact Us,

 

Terms and Conditions,

 

Support

 
The warranty period for this product is 36 months. See General Terms and Conditions of Sales for 
further details. 
 

 

Under current Italian and European laws, Datalogic is not obliged to take care of product 
disposal at the end of its life. Datalogic recommends disposing of the product in compliance with 
local laws or contacting authorised waste collection centres. 

 
© 2008 - 2017 Datalogic S.p.A. and/or its affiliates 

 ALL RIGHTS RESERVED. 

 Without limiting the 

rights under copyright, no part of this documentation may be reproduced, stored in or introduced into a 
retrieval system, or transmitted in any form or by any means, or for any purpose, without the express 
written permission of Datalogic S.p.A. and/or its affiliates. Datalogic and the Datalogic logo are registered 
trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other trademarks 
and brands are property of their respective owners. Datalogic reserves the right to make modifications 
and improvements without prior notification. 

826003245 Rev. F 

CLASS 1 EN 60825-1 (2014) 

LASER PRODUCT 

Отзывы: