S62-PL…M Laser
Background suppression
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED (yellow)
The yellow LED ON indicates the output status: N.O. closed and N.C. open.
POWER ON LED (green)
The green LED ON indicates the sensor powering status and laser emission
presence.
DISTANCE ADJUSTMENT TRIMMER (ADJ.)
The multiturn trimmer with clutch (6 turn) adjusts the suppression distance
through the mechanical variation of the optic triangulation angle.
The operating distance increases rotation the trimmer shaft in a clockwise
direction.
Please refer to “SETTING” paragraph for the correct use procedure.
POSITION INDICATOR
This indicator has a scale numbered from 1 to 6 that allows the precise
adjustment of the suppression distance on the entire operating range.
Please refer to “SETTING” paragraph for the correct use procedure.
INSTALLATION
The sensor can be positioned by means
of the three housing’s holes using two
screws (M4x25 or longer, 1.5 Nm
maximum tightening torque) with
washers.
Various orientable fixing brackets to
ease the sensor positioning are
available (please refer to the
accessories listed in the general
catalogue).
The operating distance is measured from the front surface of the sensor
optics.
The M12 connector can be oriented at two different positions using the
specific fastening spring and rotating the block to 180°.
CONNECTIONS
M12 connector
TECHNICAL DATA
S62-PL-M01…
S62-PL-M11…
Power supply:
10 … 30 VDC
Ripple:
2 Vpp max.
Consumption
(output current excluded):
30 mA max
Outputs:
PNP or NPN N.O. / N.C.; 30 VDC max. (short-circuit protection)
Output current:
100 mA (overload and overvoltage protection)
Output saturation voltage:
2 V
Response time:
140
s 200
s
Switching frequency:
3.5 kHz
2.5 kHz
Emission type:
RED LASER (
= 645…665nm): Class 1 EN 60825-1 (2014), Class II CDRH 21 CFR PART 1040.10
Pulsed emission: pot. max
5mW; pulse duration = 5
s; frequency = 14KHz (mod. M01) / 10KHz (mod. M11)
Focalisation point :
60 mm
150 mm
Spot dimension:
< 0.2 mm (at 60 mm)
< 0.4 mm (at 150 mm)
Operating distance (typical values):
30…150 mm
50…350 mm
Adjustment:
4-turn distance adjustment trimmer
6-turn distance adjustment trimmer
Difference (90% white/ 4% black):
< 4 % (see DETECTION DIAGRAM)
Hysteresis (90% white):
< 1 %
Indicators:
OUTPUT LED (YELLOW) / POWER ON LED (GREEN)
Functioning temperature:
-10 … 55 °C
Storage temperature:
-20 … 70 °C
Dielectric strength:
500 Vac 1 min., between electronics and housing
Insulating resistance:
>20 M
500 Vdc, between electronics and housing
Ambient light rejection:
According to EN 60947-5-2
Vibrations:
0.5 mm amplitude, 10 … 55 Hz frequency, for each axis (EN60068-2-6)
Shock resistance:
11 ms (30 G) 6 shock for each axis (EN60068-2-27)
Housing material:
ABS
Lens material:
PMMA window; PC lens
Mechanical protection:
IP67
Connections:
M12 4-pole connector
Weight:
40 g. max.
SETTING
Suppression distance setting
1.
Object detection
Position object to detect in front of the sensor at the distance required.
Turn distance adjustment trimmer (ADJ) to minimum: yellow LED OFF and
green LED ON.
Rotate trimmer in a clockwise direction until the yellow LED and green LED
turn ON.
Object detection condition
(A status of position indicator).
A
2.
Background suppression
Remove object and ensure that the background is in front of the sensor:
yellow LED OFF and green LED ON.
Rotate trimmer in a clockwise direction until the yellow LED and green LED
turn ON:
background detection condition
(B status of position indicator).
B
The trimmer reaches maximum level with yellow LED OFF if the background
is outside the operating range.
Rotate trimmer in an anticlockwise direction until yellow LED turns OFF
and green LED ON:
condition where background is outside operating
range
(C status of position indicator).
C
3. Setting and control
Rotate trimmer in an anticlockwise direction until the indicator reaches
an intermediate point between position A and C.
If position A and C are close to each other, leave trimmer on position C.
The sensor is now ready to function correctly and in stable conditions.
DETECTION DIAGRAM
DIMENSIONS
4.7
mm
Ø15
16
M12
18
x45°
18
DISTANCE ADJUSTMENT TRIMMER
POSITION INDICATOR
2
0.75
50
42
18.4
POWER ON LED
OUTPUT LED
10.7
11
6.18
11
6
14
50
42
1.1
EMITTER
RECEIVER
18
.2
15.5
SAFETY PRECAUTIONS
All the electric and mechanical safety regulations have to be respected during
sensor functioning.
The sensor has to be protected against mechanical damage.
Apply the labels supplied in a visible position near the laser emission beam.
The sensors are NOT safety devices, and so MUST NOT be used in the safety control of the machines
where installed.
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com:
Contact Us,
Terms and Conditions,
Support
.
The warranty period for this product is 36 months. See General Terms and Conditions of Sales for
further details.
Under current Italian and European laws, Datalogic is not obliged to take care of product
disposal at the end of its life. Datalogic recommends disposing of the product in compliance with
local laws or contacting authorised waste collection centres.
© 2008 - 2017 Datalogic S.p.A. and/or its affiliates
ALL RIGHTS RESERVED.
Without limiting the
rights under copyright, no part of this documentation may be reproduced, stored in or introduced into a
retrieval system, or transmitted in any form or by any means, or for any purpose, without the express
written permission of Datalogic S.p.A. and/or its affiliates. Datalogic and the Datalogic logo are registered
trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other trademarks
and brands are property of their respective owners. Datalogic reserves the right to make modifications
and improvements without prior notification.
826003245 Rev. F
CLASS 1 EN 60825-1 (2014)
LASER PRODUCT