1D Symbologies
Enter/Exit Programming Mode
Product Reference Guide
133
I 2 of 5 Set Length 2
This feature specifies one of the bar code lengths for
I 2 of 5 Length Control on page 131
Length 2 is the maximum label length if in
Mode, or the second
fixed length if in
Mode. The length includes the bar code’s check and
data characters.
The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length
(only one fixed length).
provides examples for setting Length 2. See
for detailed instructions on set-
ting this feature.
Table 8. I 2 of 5 Length 2 Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
Ignore This
Length
4 Characters
14 Characters
50 Characters
2
Pad with leading zeroes to
yield two digits
00
04
14
50
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT I 2 OF 5 LENGTH 2 SETTING
5
Scan Two Characters From
‘0’ and ‘0’
‘0’ and ‘4’
‘1’ and ‘4’
‘5’ AND ‘0’
6
Scan ENTER/EXIT PROGRAMMING MODE
$CI2L2
Select I 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters
Содержание QuickScan QD24 series
Страница 36: ...Enter Exit Programming Mode Global Interface Features 26 QuickScan I QD24XX QBT24XX QM24XX NOTES...
Страница 188: ...Enter Exit Programming Mode Plessey 178 QuickScan I QD24XX QBT24XX QM24XX NOTES...
Страница 220: ...Symbology Selection 210 QuickScan I QD24XX QBT24XX QM24XX NOTES...
Страница 302: ...Keypad 292 QuickScan I QD24XX QBT24XX QM24XX A B C D E F...
Страница 312: ...Scancode Tables 302 QuickScan I QD24XX QBT24XX QM24XX NOTES...