background image

Connecting the Base Station

Quick Reference Guide

5

4.

Connect to an AC Adapter, and plug the AC power cord 
into the (wall) outlet.

Figure 3. Connecting the Base Station

Host Connection — 

Verify before connection that the reader’s 

cable type is compatible with your host equipment. 

Most connections plug directly into the host device as shown 
in 

Figure 4

. Keyboard Wedge interface cables have a ‘Y’ con-

NOTE

The QuickScan QBT2400 reader can be set up to
require a PIN code when connecting to the host.
If you are adding new equipment to a system
that uses a custom security PIN, please see the
PRG for information before proceeding.

Cable Stopper

reinserted

Base

Station

I/F Cable

AC/DC
Adapter

DC Power
Cord

Wall plug
Connector

Содержание QuickScan QBT2430

Страница 1: ...QuickScan QBT2400 General Purpose Handheld Area Imager Bar Code Reader with Bluetooth Wireless Technology Quick Reference Guide...

Страница 2: ...e sentative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media If you visit our website and would like to make comments or sug...

Страница 3: ...BT2400 10 Linking the Reader 11 Link Datalogic RF Devices to Base 11 Linking to a Bluetooth Adapter in Serial Port Profile Mode 11 Linking to a Bluetooth Adapter in HID mode 12 Variable PIN Code 13 Pr...

Страница 4: ...ications 37 Datalogic Limited Factory Warranty 38 Warranty Coverage 38 Warranty Claims Process 38 Warranty Exclusions 39 No Assignment 39 Risk of Loss 40 Ergonomic Recommendations 41 Cleaning 41 Suppo...

Страница 5: ...b any other trade secrets marked appropriately or identified as proprietary or confidential and c any information that End User under the circumstances should recognize as con fidential Proprietary In...

Страница 6: ...nd User shall not use the Proprietary Information other than in conjunction with use of the Datalogic Product exclusively for End User s internal business purposes End User shall take steps to protect...

Страница 7: ...or destroy all non embedded software covered by this Agreement and shall furnish Datalogic with a certificate of compliance with this provision signed by an officer or authorized representative of En...

Страница 8: ...to reason able attorneys fees both at trial and on appeal For Asia Pacific Countries This Agreement is governed by the laws of the State of Hong Kong This Agreement and the rights of the parties here...

Страница 9: ...The QuickScan QBT2400 is a powerful omni directional reader so the orientation of the symbol is not important Datalogic s exclusive patented Green Spot for good read feedback helps to improve product...

Страница 10: ...ion see page 11 4 Select the Interface Type see page 21 5 Configure the Reader starting on page 14 optional depends on settings needed Locking the Reader to the Base The Base Station provides a lockin...

Страница 11: ...y pushing up the lever as far as it will go Figure 2 Lever in locked position NOTE it is good practice to put the scanner in the locked condition at the end of the working shift or when not in use for...

Страница 12: ...per from the bottom of the Base Station 2 Securely plug the Power Cable and Interface I F Cable connectors into their respective ports in the underside of the Base Station 3 After the cables are plugg...

Страница 13: ...host equipment Most connections plug directly into the host device as shown in Figure 4 Keyboard Wedge interface cables have a Y con NOTE The QuickScan QBT2400 reader can be set up to require a PIN c...

Страница 14: ...d port on the terminal PC Figure 4 Connecting to the Host Power Connection Plug the AC Adapter into an approved AC wall socket with the cable facing downwards as shown in Figure 3 to prevent undue str...

Страница 15: ...gure 6 QuickScan Base LEDs Table 1 Radio Base LEDs LED STATUS Power on Data Yellow On Base is powered Yellow Blinking Base receives data and commands from the Host or the Reader Charging Red On the Ba...

Страница 16: ...uickScan into the base When the scanner is fully seated in the cradle it will sound a chirp to indicate that the cradle has detected the scanner connec tion The LEDs on the base shown in Table 1 on pa...

Страница 17: ...To mount the new battery pack reverse the process 1 Insert the top of the new pack inside the reader s han dle 2 Rotate the battery pack downward while pressing the bottom side of the battery pack to...

Страница 18: ...ing system will be smaller when the reader is closer to the bar code and larger when it is farther from the code Symbolo gies with smaller bars or elements mil size should be read closer to the unit S...

Страница 19: ...nds then scan the Unlink bar code before re linking to the new base Linking to a Bluetooth Adapter in Serial Port Profile Mode 1 Install any drivers provided with the Bluetooth adapter 2 Scan the Enab...

Страница 20: ...es and select Datalogic Scanner If you receive an error message it may be necessary to disable security on the device 4 Use a text editor to see incoming data on the port designated by the computer s...

Страница 21: ...hanumeric entry enter the required variable PIN Code by scanning the cor responding bar codes in the Hex Numeric Keypad sec tion at the back of this manual for alphanumeric entry Finish by scanning th...

Страница 22: ...an the desired parameter settings scan the ENTER EXIT bar code again to accept your changes which exits Programming Mode and returns the reader to normal operation Configure Other Settings Additional...

Страница 23: ...Mode Read the configuration command label below for the HID Alt Mode feature Power Off Scan the bar code below to shut off power to the handheld until the next trigger pull PowerOff ENTER EXIT PROGRA...

Страница 24: ...r IBM AT PS2 with standard key encoding but without external keyboard AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 without Alternate Key Keyboard Wedge for IBM AT PS2 without alternate key encoding but...

Страница 25: ...continued Country Mode Croatia Country Mode Czech Republic Country Mode Denmark Country Mode France Country Mode French Canadian Country Mode Germany Supports only the interfaces listed in the Countr...

Страница 26: ...E continued Country Mode Hungary Country Mode Italy Country Mode Japanese 106 key Country Mode Lithuanian Country Mode Norway Country Mode Poland Supports only the interfaces listed in the Country Mod...

Страница 27: ...MODE continued Country Mode Portugal Country Mode Romania Country Mode Spain Country Mode Sweden Country Mode Slovakia Country Mode Switzerland Supports only the interfaces listed in the Country Mode...

Страница 28: ...to keyboard wedge interfaces It does not apply when an alternate key encoding keyboard is selected NOTE The following bar codes can be used either while in HID mode when reader is connected using Blue...

Страница 29: ...ults and additional information associated with each interface proceed to the corresponding chapter in the Quick Scan Q2400 PRG Configuring the Interface Scan the programming bar code which selects th...

Страница 30: ...S232 STD RS 232 Wincor Nixdorf Select RS232 WN RS 232 for use with OPOS UPOS JavaPOS Select RS 232 OPOS USB COM to simulate RS 232 standard interface Select USB COM STDa a Download the correct USB COM...

Страница 31: ...AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Standard Key Encoding Select KBD AT Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard Select KBD AT NK AT PS 2 25 286...

Страница 32: ...D XT Keyboard Wedge for IBM Terminal 3153 Select KBD IBM 3153 Keyboard Wedge for IBM Terminals 31xx 32xx 34xx 37xx make only keyboard Select KBD IBM M Keyboard Wedge for IBM Terminals 31xx 32xx 34xx 3...

Страница 33: ...when configured through the base See Country Mode on page 16 for programming bar codes and informa tion Caps Lock State This option specifies the format in which the reader sends character data See Ca...

Страница 34: ...eam to decode the barcode label The aiming system will briefly switch off during the acquisition time and if no code is decoded will switch on again before the next acquisition The illuminator will re...

Страница 35: ...ead green spot Use the bar codes below to specify the duration of the good read pointer beam after a good read GOOD READ GREEN SPOT DURATION ENTER EXIT PROGRAMMING MODE Green Spot Duration Disable Gre...

Страница 36: ...pulled again to transition to another state Double Read Timeout1 prevents undesired multiple reads while in this mode Flashing The reader flashes1 on and off regardless of the trigger status Always O...

Страница 37: ...uick Reference Guide 29 SCAN MODES ENTER EXIT PROGRAMMING MODE Scan Mode Trigger Single Scan Mode Trigger Hold Multiple Scan Mode Trigger Pulse Multiple Scan Mode Flashing Scan Mode Always On Scan Mod...

Страница 38: ...er Single mode If the scanner switches to a different Read Mode Pick Mode is automatically disabled Multiple Labels in a Volume Enables disables the ability of scanner to decode multiple labels in the...

Страница 39: ...tely 200 g reader 230 g base charger Electrical Characteristics Battery Type Li Ion battery pack Typical charge time for full charge from full discharge 6 hours with Host Power through the micro USB c...

Страница 40: ...mils DOF based on EAN All other 1D codes are Code 39 All labels grade A typical environmental light 20 C label inclination 10 Symbology Code 39 5mil 0 2 5 9 0 5 15cm 10mil 0 8 7 0 22cm 20mil up to 16...

Страница 41: ...Aztec Datamatrix Inverse Datamatrix Data matrix is configurable for the following parameters Normal or Inverted Square or Rectangular Style Data length 1 3600 char acters Maxicode QR Codes QR Micro Q...

Страница 42: ...ecifications Scanner withstands 18 drops from 1 5 m 4 9 feet to concrete Ambient Light Immunity Up to 100 000 Lux Contaminants Spray rain Dust particulates IEC 529 IP42 scanner only ESD Level 16 KV Re...

Страница 43: ...at highest fre quency and vol ume upon power up Good Read Beep A label has been successfully scanned by the reader LED behavior for this indication is configurable via thefeature Good Read When to Ind...

Страница 44: ...abel A label has been rejected N A Reader sounds three times at lowest fre quency and cur rent volume Label Program ming Mode Accep tance of Partial Label In cases where multiple labels must bescanned...

Страница 45: ...1 Configuration Contact Helpdesk for assis tance 2 Interface PCB 6 Digital PCB 12 Imager Indication LEDs Power up Complete Yellow LED on Reader Disabled by the HOST or the communication with HOST is...

Страница 46: ...p all parts removed from the repaired prod uct The warranty period shall extend from the date of ship ment from Datalogic for the duration published by Datalogic for the product at the time of purchas...

Страница 47: ...lty operations improper use abuse misuse wear and tear negligence improper storage or use of parts or accessories not approved or supplied by Datalogic iii any claimed defect or damage caused by the u...

Страница 48: ...OMER S SOLE AND EXCLUSIVE REMEDY FOR WARRANTY CLAIMS UNDER NO CIRCUMSTANCES WILL DATALOGIC BE LIABLE TO CUSTOMER OR ANY THIRD PARTY FOR ANY LOST PROFITS OR ANY INCIDENTAL CONSEQUEN TIAL IN DIRECT SPEC...

Страница 49: ...nce during scanning operations Contacts on the scanner and the base should also be cleaned as needed to ensure a good connection Be sure to unplug the reader and base before cleaning Use a soft dry cl...

Страница 50: ...PPORT GENERAL DUTY HANDHELD SCANNERS category link From this page you can select your product model from the dropdown list which gives you access to Downloads including Data Sheets Manuals Software Ut...

Страница 51: ...Hex Numeric Keypad Quick Reference Guide 43 Hex Numeric Keypad Use the bar codes that follow to enter numbers as you would select digits characters from a keypad 0 1 2 3 4 5...

Страница 52: ...Hex Numeric Keypad 44 QuickScan QBT2400 Hex Numeric Keypad continued 6 7 8 9 A B...

Страница 53: ...D E F For HID Variable Pin Code only If you make a mistake scan the CANCEL barcode below to abort and not save the entry string You can then restart Finish by scanning the Exit HID Variable PIN Code l...

Страница 54: ...Hex Numeric Keypad 46 QuickScan QBT2400 NOTES...

Страница 55: ...Hex Numeric Keypad Quick Reference Guide 47 NOTES...

Страница 56: ...Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S and the E U Datalogic USA Inc 959 Terry Street Eugene OR 97402 U S A Telephone 541 68...

Отзывы: