background image

Symbologies

304

QuickScan

TM

 QD2100

Plessey — cont.

Plessey Decoding Level

Decoding Levels are used to configure a bar code symbology decoder to be very aggressive 
to very conservative depending on a particular customer’s needs.

Choosing Level 1 results in a very conservative decoder at the expense of not being able to 
read poorly printed or damaged labels.

Choosing Level 5 results in a very aggressive decoder. This aggressive behavior allows 
decoding of poorly printed and damaged labels at the expense of increasing the likelihood 
of decoding errors.

Choosing Level 3, which is the default setting, allows the majority of product labels to be 
decoded.

There are many factors that determine when to change the decoding level for a particular 
symbology. These factors include spots, voids, non-uniform bar/space widths, damaged 
labels, etc. that may be experienced in some bar code labels. If there are many hard to 
read or damaged labels that cannot be decoded using a conservative setting, increase the 
decoding level to be more aggressive. If the majority of labels are very good quality labels, 
or there is a need to decrease the possibility of a decoder error, lower the decoding level 
to a more conservative level.

ENTER/EXIT PROGRAMMING MODE

Plessey Decoding Level = Disable

Plessey Decoding Level = 1

Plessey Decoding Level = 2

Содержание QuickScan i QD2100

Страница 1: ...QuickScanTM i QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide...

Страница 2: ...15831 5019697 5019698 5086879 5115120 5144118 5146463 5179270 5198649 5200597 5202784 5208449 5210397 5212371 5212372 5214270 5229590 5231293 5232185 5233169 5235168 5237161 5237162 5239165 5247161 52...

Страница 3: ...n Transmission 9 Resetting the Product Configuration to Defaults 9 Chapter 3 Interfaces 11 Interface Selection 11 Configuring the Interface 11 Global Interface Features 15 Host Commands Obey Ignore 15...

Страница 4: ...tion 67 Standard Factory Settings 67 Scancode Tables 67 Country Mode 68 Caps Lock State 71 Numlock 71 Send Control Characters 72 Wedge Quiet Interval 73 Intercharacter Delay 75 Intercode Delay 77 USB...

Страница 5: ...25 In Store Minimum Reads 126 UPC E 127 UPC E Enable Disable 127 UPC E Check Character Transmission 127 Expand UPC E to EAN 13 128 Expand UPC E to UPC A 128 UPC E Number System Character Transmission...

Страница 6: ...ength Control 174 Code 39 Set Length 1 175 Code 39 Set Length 2 177 Code 39 Interdigit Ratio 179 Code 39 Character Correlation 181 Code 39 Stitching 182 Code 32 Italian Pharmaceutical 183 Code 32 Enab...

Страница 7: ...Codabar Minimum Reads 232 Codabar Decoding Level 233 Codabar Length Control 235 Codabar Set Length 1 236 Codabar Set Length 2 238 Codabar Interdigit Ratio 240 Codabar Character Correlation 242 Codabar...

Страница 8: ...cter Transmission 288 MSI Length Control 288 MSI Set Length 1 289 MSI Set Length 2 291 MSI Minimum Reads 293 MSI Decoding Level 294 Plessey 296 Plessey Enable Disable 296 Plessey Check Character Calcu...

Страница 9: ...nable Disable 332 Appendix A Technical Specifications 333 Standard Cable Pinouts 335 Appendix B Standard Defaults 337 Default Exceptions 348 Appendix C LED and Beeper Indications 351 LED and Beeper In...

Страница 10: ...8 QuickScanTM QD2100 NOTES...

Страница 11: ...ing a serial or USB cable and can also create configuration bar codes to print Manual Overview Chapter 1 Introduction provides a product overview unpacking instructions and cable connection informatio...

Страница 12: ...certain parameter set tings Appendix F Scancode Tables lists control character emulation information for Wedge and USB Keyboard interfaces Manual Conventions The following conventions are used in thi...

Страница 13: ...os and in structions for returning products for repair Reseller Technical Support An excellent source for technical assistance and information is an authorized Datalogic reseller A reseller is acquain...

Страница 14: ...Introduction 4 QuickScanTM QD2100 NOTES...

Страница 15: ...ts scanned data as keystrokes and supports several international keyboards for the Win dows environment See Country Mode on page 68 for a full listing USB Select to communicate either by USB OEM USB C...

Страница 16: ...able clip with its opening as shown in the insert portion of Figure 1 RS 232 Serial Connection Turn off power to the terminal PC and connect the im ager to the terminal PC serial port via the RS 232 c...

Страница 17: ...Figure 2 Other Interface Connections US B IB M K e yboard W edge or or NOTE Specific cables are required for connection to different hosts The connectors illustrated above are examples only Actual con...

Страница 18: ...programming for the interface type the imager is connected to for example RS 232 Keyboard Wedge USB etc and scan the appropriate bar code in that section to select your system s correct interface typ...

Страница 19: ...efaults If you aren t sure what programming options are in your imager or you ve changed some options and want to restore the Custom Default Configuration that may have been saved in the imager scan t...

Страница 20: ...r code below Both labels restore the imager configuration to the factory set tings including the interface type The USA label restores Label IDs to those historically used in the USA The EU label rest...

Страница 21: ...be connected to Next proceed to the corre sponding chapter in this manual also listed in Table 1 to configure any desired settings and features associated with that interface NOTE Unlike some other p...

Страница 22: ...JavaPOS Select RS 232 OPOS Select USB COM STDa a Download the correct USB Com driver from www datalogic com USB Com to simulate RS 232 standard interface IBM FEATURES Select IBM P5B IBM 46xx Port 5B...

Страница 23: ...page 67 Select KBD AT NK Keyboard Wedge for IBM AT PS2 with stan dard key encoding but without external key board AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 w Alternate Key Select KBD AT ALT Select K...

Страница 24: ...oard Wedge for IBM Terminals 31xx 32xx 34xx 37xx make break keyboard Keyboard Wedge for DIGITAL Terminals VT2xx VT3xx VT4xx Select KBD DIG VT Select USB Keyboard USB Keyboard with standard key encodin...

Страница 25: ...n page 41 Keyboard Interface on page 67 USB OEM Interface on page 81 IBM 46XX Interface on page 85 Host Commands Obey Ignore This option specifies whether the reader will obey or ignore host commands...

Страница 26: ...es 16 QuickScanTM QD2100 USB Suspend Mode This setting enables disables the ability of USB interfaces to enter suspend mode ENTER EXIT PROGRAMMING MODE DEFAULT USB Suspend Mode Disable USB Suspend Mod...

Страница 27: ...logy and data If the unit reads a label and sees the same label again within the Double Read Timeout the second read of the label will be ignored Double Read Timeout does not apply to scan modes that...

Страница 28: ...ouble Read Timeout continued ENTER EXIT PROGRAMMING MODE Double Read Timeout 0 5 Second Double Read Timeout 0 6 Second Double Read Timeout 0 7 Second Double Read Timeout 0 8 Second Double Read Timeout...

Страница 29: ...ECT LABEL GONE TIMEOUT SETTING 5 Scan the appropriate three alpha numeric characters from the keypad in Appendix E Keypad representing the duration which was determined in the steps above You will hea...

Страница 30: ...bel Gone Timeout cont ENTER EXIT PROGRAMMING MODE Select Label Gone Timeout Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the begin...

Страница 31: ...Guide 21 LED and Beeper Indicators Power On Alert Disables or enables the indication from the Beeper that the reader is receiving power ENTER EXIT PROGRAMMING MODE Power On Alert Disable No Audible I...

Страница 32: ...reading a bar code Choices are Good Read Indicate after decode Good Read Indicate after transmit Good Read Indicate after CTS goes inactive then activ NOTE This option which uses CTS is only valid fo...

Страница 33: ...ndicators Product Reference Guide 23 Good Read Beep Type Specifies whether the good read beep has a mono or bitonal beep sound ENTER EXIT PROGRAMMING MODE Good Read Beep Type Mono Good Read Beep Type...

Страница 34: ...high frequency se lectable from the list below Controls the beeper s pitch tone Good Read Beep Length Specifies the duration of a good read beep ENTER EXIT PROGRAMMING MODE Good Read Beep Frequency Lo...

Страница 35: ...Length continued ENTER EXIT PROGRAMMING MODE Good Read Beep Length 80 msec Good Read Beep Length 100 msec Good Read Beep Length 120 msec Good Read Beep Length 140 msec Good Read Beep Length 160 msec G...

Страница 36: ...olume Selects the beeper volume loudness upon a good read beep There are three selectable volume levels ENTER EXIT PROGRAMMING MODE Good Read Beep Volume Beeper Off Good Read Beep Volume Low Good Read...

Страница 37: ...5 Scan the appropriate three digits from the keypad in Appendix E Keypad representing the duration which was determined in the steps above You will hear a two beep indica tion after the last character...

Страница 38: ...100 Good Read LED Duration cont ENTER EXIT PROGRAMMING MODE Select Good Read LED Duration Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start agai...

Страница 39: ...til Scanning Active Time has elapsed or the trigger has been released and pulled again Double Read Timeout1 prevents undesired multiple reads of the same label while in this mode Flashing The reader f...

Страница 40: ...Scan Mode continued ENTER EXIT PROGRAMMING MODE Scan Mode Trigger Single Scan Mode Trigger Hold Multiple Scan Mode Trigger Pulse Multiple Scan Mode Flashing Scan Mode Always On Scan Mode Stand Mode S...

Страница 41: ...rigger is pulled while in Stand Mode NOTE ENTER EXIT PROGRAMMING MODE Stand Mode Triggered Timeout 0 5 Seconds Stand Mode Triggered Timeout 1 5 Seconds Stand Mode Triggered Timeout 2 Seconds DEFAULT S...

Страница 42: ...anTM QD2100 Stand Mode Triggered Timeout continued ENTER EXIT PROGRAMMING MODE Stand Mode Triggered Timeout 6 Seconds Stand Mode Triggered Timeout 8 Seconds Stand Mode Triggered Timeout Switch to Cont...

Страница 43: ...t repre sent the duration which was determined in the steps above You will hear a two beep indi cation after the last character NOTE If you make a mistake before the last character scan the CANCEL bar...

Страница 44: ...ive Time cont ENTER EXIT PROGRAMMING MODE Select Scanning Active Time Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning C...

Страница 45: ...n Appendix E Keypad representing the duration which was determined in the steps above You will hear a two beep indica tion after the last character NOTE If you make a mistake before the last character...

Страница 46: ...Flash On Time cont ENTER EXIT PROGRAMMING MODE Select Flash ON Time Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning CAN...

Страница 47: ...in Appendix E Keypad that represent the duration which was determined in the steps above You will hear a two beep indica tion after the last character NOTE If you make a mistake before the last charac...

Страница 48: ...Flash Off Time cont ENTER EXIT PROGRAMMING MODE Select Flash OFF Time Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning C...

Страница 49: ...nce Guide 39 Stand Mode Sensitivity Sets the sensitivity level for stand mode wakeup Choices are low medium and high ENTER EXIT PROGRAMMING MODE Stand Mode Sensitivity Low Stand Mode Sensitivity Mediu...

Страница 50: ...Specifies the duration of the good read pointer beam after a good read ENTER EXIT PROGRAMMING MODE Green Spot Duration Disable Green Spot is Off Green Spot Duration Short 300 msec Green Spot Duration...

Страница 51: ...USB interfaces are available in Chapter 6 RS 232 USB Com Interfaces RS 232 Standard Factory Settings Reference Appendix B Standard Defaults for a listing of standard factory settings Baud Rate Baud r...

Страница 52: ...RS 232 ONLY Interface 42 QuickScanTM QD2100 Baud Rate continued ENTER EXIT PROGRAMMING MODE Baud Rate 9600 Baud Rate 19 200 Baud Rate 38 400 Baud Rate 57 600 Baud Rate 115 200 DEFAULT...

Страница 53: ...ference Guide 43 Data Bits This parameter allows the reader to interface with devices requiring a 7 bit or 8 bit AS CII protocol for sending and receiving data ENTER EXIT PROGRAMMING MODE 7 Data Bits...

Страница 54: ...of one character and prepares the receiving device for the next character in the serial data stream The number of stop bits selected one or two depends on the number the receiv ing terminal is program...

Страница 55: ...ice requirements Select None when no parity bit is required Select Odd parity and the parity bit value is set to 0 or 1 based on data to ensure that an odd number of 1 bits are contained in the coded...

Страница 56: ...RTS is asserted during transmissions CTS gates transmissions RTS XON XOFF RTS is asserted during transmissions CTS is ignored XON and XOFF gate transmissions RTS On CTS RTS is always asserted CTS gat...

Страница 57: ...B Com Interfaces Introduction The programming bar codes in this chapter allow modifications to the standard RS 232 and USB Com interfaces Standard Factory Settings Reference Appendix B Standard Defaul...

Страница 58: ...ate two digits from the keypad in Appendix E Keypad that represent the duration which was determined in the steps above You will hear a two beep indica tion after the last character NOTE If you make a...

Страница 59: ...lay cont ENTER EXIT PROGRAMMING MODE Intercharacter Delay No Delay Select Intercharacter Delay Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start...

Страница 60: ...gain a user s attention to an illegal entry or other important event ENTER EXIT PROGRAMMING MODE Beep On ASCII BEL Disable DEFAULT Beep On ASCII BEL Enable Beep On Not on File This option enables dis...

Страница 61: ...label transmission The reader expects an ACK NAK response from the host when a label is sent Enable for host command acknowledge The reader will respond with ACK NAK when the host sends a command Ena...

Страница 62: ...aracter value 3 Scan the ENTER EXIT PROGRAMMING MODE bar code to enter Programming Mode 4 Scan the bar code SELECT ACK CHARACTER SETTING 5 Scan the appropriate two alpha numeric characters from the ke...

Страница 63: ...ACK NAK Options Product Reference Guide 53 ACK Character cont ENTER EXIT PROGRAMMING MODE Select ACK Character Setting DEFAULT 0x06 ACK Character...

Страница 64: ...aracter value 3 Scan the ENTER EXIT PROGRAMMING MODE bar code to enter Programming Mode 4 Scan the bar code SELECT NAK CHARACTER SETTING 5 Scan the appropriate two alpha numeric characters from the ke...

Страница 65: ...ACK NAK Options Product Reference Guide 55 NAK Character cont ENTER EXIT PROGRAMMING MODE Select NAK Character Setting DEFAULT 0x15 NAK Character...

Страница 66: ...Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the duration which was determined in the steps above You will hear a two beep indica tion after the last character...

Страница 67: ...imeout Value cont ENTER EXIT PROGRAMMING MODE Select ACK NAK Timeout Value Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginn...

Страница 68: ...ix E Keypad that repre sent the number which was determined in the steps above You will hear a two beep indi cation after the last character NOTE If you make a mistake before the last character scan t...

Страница 69: ...59 ACK NAK Retry Count cont ENTER EXIT PROGRAMMING MODE Select ACK NAK Retry Count Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at th...

Страница 70: ...ile waiting for an ACK character from the host Options are Ignore errors detected Process error as valid ACK character Process error as valid NAK character ENTER EXIT PROGRAMMING MODE DEFAULT ACK NAK...

Страница 71: ...ion Failure This option enables disables the reader s ability to sound an error beep to indicate a transmission failure while in ACK NAK mode ENTER EXIT PROGRAMMING MODE Indicate Transmission Failure...

Страница 72: ...desired character value 3 Scan the ENTER EXIT PROGRAMMING MODE bar code to enter Programming Mode 4 Scan the bar code SELECT DISABLE CHARACTER SETTING 5 Scan the appropriate two alpha numeric charact...

Страница 73: ...Disable Character Product Reference Guide 63 Disable Character cont ENTER EXIT PROGRAMMING MODE Select Disable Character Setting DEFAULT 0x44 Disable Character is D...

Страница 74: ...hex equivalent for the desired character value 3 Scan the ENTER EXIT PROGRAMMING MODE bar code to enter Programming Mode 4 Scan the bar code SELECT ENABLE CHARACTER SETTING 5 Scan the appropriate two...

Страница 75: ...Enable Character Product Reference Guide 65 Enable Character cont ENTER EXIT PROGRAMMING MODE Select Enable Character Setting DEFAULT 0x45 Enable Character is E...

Страница 76: ...RS 232 USB Com Interfaces 66 QuickScanTM QD2100 NOTES...

Страница 77: ...apter to select options for USB Keyboard and Wedge Interfaces Standard Factory Settings Reference Appendix B Standard Defaults for a listing of standard factory settings Scancode Tables Information ab...

Страница 78: ...rd AT PS 2 25 286 30 286 50 50Z 60 70 80 90 95 without Alternate Key Keyboard Wedge for IBM AT PS2 without alternate key encoding but without external keyboard All other interfaces support ONLY the fo...

Страница 79: ...re description Country Mode France Country Mode Germany Supports only the interfaces listed in theCountry Mode fea ture description Country Mode Hungary Country Mode Italy Supports only the interfaces...

Страница 80: ...rfaces listed in theCountry Mode fea ture description Country Mode Portugal Country Mode Romania Supports only the interfaces listed in theCountry Mode fea ture description Supports only the interface...

Страница 81: ...is selected ENTER EXIT PROGRAMMING MODE DEFAULT Caps Lock State Caps Lock OFF Caps Lock State Caps Lock ON Caps Lock State AUTO Caps Lock Enable Numlock This option specifies the setting of the Number...

Страница 82: ...l Keys special keys are located from 0x80 to 0xA1 Control Character 01 Characters from 00 to 0x1F are sent as control character Ctrl Cap ital Key special keys are located from 0x80 to 0xA1 Control Cha...

Страница 83: ...QUIET INTERVAL SETTING 5 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the duration which was determined in the steps above You will hear a two beep indica tion...

Страница 84: ...Quiet Interval cont ENTER EXIT PROGRAMMING MODE Select Wedge Quiet Interval Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the begin...

Страница 85: ...AY SETTING 5 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the duration which was determined in the steps above You will hear a two beep indica tion after the las...

Страница 86: ...cont ENTER EXIT PROGRAMMING MODE Intercharacter Delay No Delay Select Intercharacter Delay Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start aga...

Страница 87: ...the duration which was determined in the steps above You will hear a two beep indica tion after the last character NOTE If you make a mistake before the last character scan the CANCEL bar code to abor...

Страница 88: ...100 Intercode Delay cont ENTER EXIT PROGRAMMING MODE Set Intercode Delay Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning CANCEL...

Страница 89: ...s option specifies the USB poll rate for a USB keyboard NOTE ENTER EXIT PROGRAMMING MODE DEFAULT USB Keyboard Speed 1ms USB Keyboard Speed 2ms USB Keyboard Speed 3ms USB Keyboard Speed 4ms USB Keyboar...

Страница 90: ...d Interface 80 QuickScanTM QD2100 USB Keyboard Speed continued ENTER EXIT PROGRAMMING MODE USB Keyboard Speed 6ms USB Keyboard Speed 7ms USB Keyboard Speed 8ms USB Keyboard Speed 9ms USB Keyboard Spee...

Страница 91: ...reader will be connected with Use the feature settings in this chapter and Chapter 9 IBM 46XX Interface to specifically configure for the USB OEM interface Other USB interfaces are included in the ap...

Страница 92: ...rs you may already have con nected to a USB OEM POS you may need to change this setting to enable all devices to communicate Options are Table Top Scanner Handheld Scanner NOTE ENTER EXIT PROGRAMMING...

Страница 93: ...ns This setting provides for an interface specific control mechanism Options are Obey Obey Scanner Configuration Host Commands Ignore Ignore Scanner Configuration Host Commands ENTER EXIT PROGRAMMING...

Страница 94: ...USB OEM Interface 84 QuickScanTM QD2100 NOTES...

Страница 95: ...6XX Interface Introduction Use the bar codes in this section to configure programmable features for available IBM 46XX interfaces IBM Standard Factory Settings Reference Appendix B Standard Defaults f...

Страница 96: ...second period to allow the user to enter Programming Mode and configure the reader The con figurable range for this feature is 1 to 15 resets ENTER EXIT PROGRAMMING MODE 46xx Number of Host Resets 1 4...

Страница 97: ...st Resets 7 46xx Number of Host Resets 8 46xx Number of Host Resets 9 46xx Number of Host Resets 10 46xx Number of Host Resets 11 46xx Number of Host Resets 12 46xx Number of Host Resets Product Refer...

Страница 98: ...ENTER EXIT PROGRAMMING MODE 46xx Number of Host Resets 13 46xx Number of Host Resets 14 46xx Number of Host Resets 15 IBM 46XX Interface 88 QuickScanTM QD2100 46xx Number of Host Resets cont...

Страница 99: ...ranslation The data is not converted to Code 39 or verified to be valid for Code 39 Options are IBM Standard Format Send labels in standard IBM format Code 39 Format Translate the following symbologie...

Страница 100: ...s setting provides for an interface specific control mechanism Options are Obey Obey Scanner Configuration Host Commands Ignore Ignore Scanner Configuration Host Commands ENTER EXIT PROGRAMMING MODE U...

Страница 101: ...erface Wand Emulation Standard Factory Settings Reference Appendix B Standard Defaults for a listing of standard factory settings Wand Idle State This feature specifies the level of the Wand output si...

Страница 102: ...Wand output signal Choices are Quiet zones and spaces are high bars are low Quiet zones and spaces are low bars are high NOTE ENTER EXIT PROGRAMMING MODE Wand Polarity Quiet Zones Spaces High Bars Lo...

Страница 103: ...ide 93 Wand Signal Speed This feature specifies the speed of the Wand output signal per nominal bar or space Choices are 330 microseconds 660 microseconds ENTER EXIT PROGRAMMING MODE Wand Signal Speed...

Страница 104: ...erted to a single symbology Options are No conversion Convert to Code 39 symbology Convert to Code 39 Full ASCII Convert to Code 128 symbology ENTER EXIT PROGRAMMING MODE DEFAULT Label Symbology Conve...

Страница 105: ...Wand interface Choices are Disable no leading trailing noise Enable leading noise Enable trailing noise Enable leading and trailing noise ENTER EXIT PROGRAMMING MODE DEFAULT Transmit Noise Disable Tra...

Страница 106: ...Wand Emulation Interface 96 QuickScanTM QD2100 NOTES...

Страница 107: ...can specify if they should be sent with all symbologies or only with specific symbologies Figure 3 shows the available elements you can add to a message string Figure 3 Breakdown of a Message String...

Страница 108: ...tion before the bar code data and or as a suffix in a position following the bar code data as indicated in Figure 4 Figure 4 Prefix and Suffix Positions Prefix Suffix AIM ID Label ID Label ID Bar Code...

Страница 109: ...place the unit in Programming Mode then the Set Global Prefix or Set Global Suffix bar code followed by the digits in hex from the Alphanumeric characters in Appendix E Keypad representing your desire...

Страница 110: ...ose brace character ASCII followed by A code character see the table below followed by A modifier character the modifier character is symbol dependent SYMBOLOGY CHA R SYMBOLOGY CHA R UPC EAN Ea a UPC...

Страница 111: ...Global AIM ID Product Reference Guide 101 Global AIM ID continued ENTER EXIT PROGRAMMING MODE Global AIM ID Disable Global AIM ID Enable DEFAULT...

Страница 112: ...D for GS1 128 can be enabled disabled inde pendently The AIM ID for GS1 128 is a C1 C2 or C3 AIM IDs for other symbologies can be enabled disabled independently as well Contact Customer Support for as...

Страница 113: ...el ID Set Individually Per Symbology on page 106 If you wish to program the read er to always include an industry standard label identifier for ALL symbology types see the previous feature Global AIM...

Страница 114: ...00 CODE39 2A0000 V 560000 CODE4 4 340000 4 340000 CODE5 j 6A0000 j 6A0000 CODE93 260000 U 550000 DATALOGIC 2OF5 s 730000 s 730000 EAN13 F 460000 B 420000 EAN13 P2 F 460000 L 4C0000 EAN13 P5 F 460000 M...

Страница 115: ...000 400000 ISBT128 f 660000 f 660000 ISSN n 6E0000 n 6E0000 MSI 400000 Z 5A0000 Plessey a 610000 a 610000 S25 s 730000 P 500000 UPCA A 410000 C 430000 UPCA P2 A 410000 F 460000 UPCA P5 A 410000 G 4700...

Страница 116: ...to the ASCII Character Set on the inside back cover of this manual and find the equivalent hex digits associated with your choice of Label ID For example if you wish to select an equal sign as a Label...

Страница 117: ...e 109 GS1 DataBar Omnidirectional Code 39 Interleaved 2 of 5 Code 32 4 Custom Label ID example desired characters D B C 3 P H 5 Find hex equivalents from the ASCII table inside back cover then scan in...

Страница 118: ...sent as a prefix or suffix for a given symbology type ENTER EXIT PROGRAMMING MODE DEFAULT Label ID Transmission Disable Label ID Transmission Enable as Prefix Label ID Transmission Enable as Suffix C...

Страница 119: ...for which a Label ID is to be configured See Label ID on page 103 ENTER EXIT PROGRAMMING MODE Set UPC A Label ID Character s Set UPC A P2 Label ID Character s Set UPC A P5 Label ID Character s Set UPC...

Страница 120: ...or which a Label ID is to be configured See Label ID on page 103 for full instructions ENTER EXIT PROGRAMMING MODE Set UPC E P5 Label ID Character s Set UPC E GS1 128 Label ID Character s Set EAN 13 L...

Страница 121: ...ology for which a Label ID is to be configured See Label ID on page 103 for full instructions ENTER EXIT PROGRAMMING MODE Set EAN 8 Label ID Character s Set EAN 8 P2 Label ID Character s Set EAN 8 P5...

Страница 122: ...ID is to be configured See Label ID on page 103 for full instructions ENTER EXIT PROGRAMMING MODE Set GTIN P5 Label ID Character s Set GTIN GS1 128 Label ID Character s Set GS1 DataBar Omnidirectional...

Страница 123: ...igured See Label ID on page 103 for full instructions ENTER EXIT PROGRAMMING MODE Set Code 32 Label ID Character s Set Code 39 CIP Label ID Character s Set Code 128 Label ID Character s Set GS1 128 La...

Страница 124: ...r which a Label ID is to be configured See Label ID on page 103 for full instructions ENTER EXIT PROGRAMMING MODE Set Codabar Label ID Character s Set ABC Codabar Label ID Character s Set Code 11 Labe...

Страница 125: ...for which a Label ID is to be configured See Label ID on page 103 for full instructions ENTER EXIT PROGRAMMING MODE Set IATA Label ID Character s Set Concatinated ISBT 128 Label ID Character s Set MS...

Страница 126: ...d This option selects the symbology for which a Label ID is to be configured See Label ID on page 103 for full instructions ENTER EXIT PROGRAMMING MODE Set Codablock F Label ID Character s Set Code 4...

Страница 127: ...etic characters to upper or lower case NOTE ENTER EXIT PROGRAMMING MODE DEFAULT Case Conversion Disable no case conversion Case Conversion Convert to upper case Case Conversion Convert to lower case C...

Страница 128: ...label AB12BA21 it would look as follows after the character conversion BB22BB22 The A characters were converted to B characters and the 1 characters were converted to 2 characters Nothing is done with...

Страница 129: ...Character Conversion Product Reference Guide 119 Character Conversion continued ENTER EXIT PROGRAMMING MODE Configure Character Conversion DEFAULT 0xFFFFFFFFFFFFFFFF No character conversion...

Страница 130: ...Data Editing 120 QuickScanTM QD2100 NOTES...

Страница 131: ...abar GTIN Formatting ABC Codabar EAN 13 JAN 13 Code 11 EAN 8 JAN 8 Standard 2 of 5 Add Ons Industrial 2 of 5 GS1 DataBarTM Omnidirectional IATA GS1 DataBarTM Expanded ISBT 128 GS1 DataBarTM Limited MS...

Страница 132: ...n arrow Also reference Appendix B Standard Defaults for a listing of the most widely used set of standard fac tory settings That section also provides space to record any custom settings needed or imp...

Страница 133: ...bles only GS1 DataBar coupon decoding To set this feature 1 Scan the SWITCH bar code 2 Scan either the enable or disable bar code below You ll need to cover any unused bar codes on this and the facing...

Страница 134: ...der will not read UPC A bar codes ENTER EXIT PROGRAMMING MODE UPC A Disable UPC A Enable DEFAULT UPC A Check Character Transmission Enable this option to transmit the check character along with UPC A...

Страница 135: ...to match those required for EAN 13 ENTER EXIT PROGRAMMING MODE DEFAULT UPC A to EAN 13 Don t Expand UPC A to EAN 13 Expand UPC A Number System Character Transmission This feature enables disables tran...

Страница 136: ...e it is accepted as good read In store labels are defined as UPC A labels with a number system character of 2 or 4 as well as EAN 8 and EAN 13 labels with a Flag1 character of 2 or an EAN 13 label sta...

Страница 137: ...er will not read UPC E bar codes ENTER EXIT PROGRAMMING MODE UPC E Disable UPC E Enable DEFAULT UPC E Check Character Transmission Enable this option to transmit the check character along with UPC E b...

Страница 138: ...ing this feature also changes the symbology ID to match those required for EAN 13 ENTER EXIT PROGRAMMING MODE DEFAULT UPC E to EAN 13 Don t Expand UPC E to EAN 13 Expand Expand UPC E to UPC A Expands...

Страница 139: ...UPC E Number System Character Transmission This feature enables disables transmission of the UPC E system number character ENTER EXIT PROGRAMMING MODE UPC E Number System Character Do not transmit UP...

Страница 140: ...m Reads This feature specifies the minimum number of consecutive times a UPC E label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE UPC E Minimum Reads 1 UPC E Minimum...

Страница 141: ...UPC E UPC A EAN 8 and EAN 13 labels into the GTIN 14 character format NOTE ENTER EXIT PROGRAMMING MODE DEFAULT GTIN Formatting Disable GTIN Formatting Enable If add on information is present on the ba...

Страница 142: ...r will not read EAN 13 JAN 13 bar codes ENTER EXIT PROGRAMMING MODE EAN 13 Disable EAN 13 Enable DEFAULT EAN 13 Check Character Transmission Enable this option to transmit the check character along wi...

Страница 143: ...nt EAN 13 Flag 1 Character Enables disables transmission of an EAN JAN13 Flag1 character The Flag 1 character is the first character of the label ENTER EXIT PROGRAMMING MODE EAN 13 Flag 1 Char Don t t...

Страница 144: ...and labels starting with 978 to ISBN labels ENTER EXIT PROGRAMMING MODE DEFAULT EAN 13 ISBN Conversion Disable EAN 13 ISBN Conversion Convert to ISBN ISSN Enable Disable Enables disables conversion of...

Страница 145: ...eads This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE DEFAULT EAN 13 Minimum Reads 1 EAN 13...

Страница 146: ...der will not read EAN 8 JAN 8 bar codes ENTER EXIT PROGRAMMING MODE EAN 8 Disable EAN 8 Enable DEFAULT EAN 8 Check Character Transmission Enable this option to transmit the check character along with...

Страница 147: ...eference Guide 137 EAN 8 cont Expand EAN 8 to EAN 13 Enable this option to expand EAN 8 JAN 8 labels to EAN 13 JAN 13 ENTER EXIT PROGRAMMING MODE DEFAULT Expand EAN 8 to EAN 13 Disable Expand EAN 8 to...

Страница 148: ...ads This feature specifies the minimum number of consecutive times an EAN 8 Jan 8 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE DEFAULT EAN 8 Minimum Reads 1 EAN...

Страница 149: ...oder This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors Choosing Level 3 which is the default setting allows t...

Страница 150: ...M QD2100 UPC EAN Global Settings cont UPC EAN Decoding Level cont ENTER EXIT PROGRAMMING MODE UPC EAN Decoding Level 1 UPC EAN Decoding Level 2 UPC EAN Decoding Level 3 UPC EAN Decoding Level 4 UPC EA...

Страница 151: ...el data from multiple scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correla...

Страница 152: ...lation Enable 5 digit price weight check digit calculation Enable European 4 digit price weight check digit calculation Enable European 5 digit price weight check digit calculation ENTER EXIT PROGRAMM...

Страница 153: ...cont UPC A Minimum Reads This feature specifies the minimum number of consecutive times a UPC A label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE DEFAULT UPC A Minim...

Страница 154: ...plementals P2 P5 GS1 128 NOTE ENTER EXIT PROGRAMMING MODE DEFAULT Optional Add Ons Disable P2 Optional Add Ons Enable P2 DEFAULT Optional Add Ons Disable P5 If a UPC EAN base label and a an add on are...

Страница 155: ...Add Ons Product Reference Guide 145 Add Ons cont Optional Add ons cont ENTER EXIT PROGRAMMING MODE Optional Add Ons Enable P5 Optional Add Ons Disable GS1 128 Optional Add Ons Enable GS1 128 DEFAULT...

Страница 156: ...will look for an add on when an add on fragment has been seen and optional add ons are enabled Also see Optional GS1 128 Add On Timer on page 149 ENTER EXIT PROGRAMMING MODE Optional Add on Timer 10ms...

Страница 157: ...Ons cont Optional Add On Timer cont ENTER EXIT PROGRAMMING MODE Optional Add on Timer 60ms Optional Add on Timer 70ms Optional Add on Timer 100ms Optional Add on Timer 120ms Optional Add on Timer 140...

Страница 158: ...ptional Add On Timer cont ENTER EXIT PROGRAMMING MODE Optional Add on Timer 180ms Optional Add on Timer 200ms Optional Add on Timer 220ms Optional Add on Timer 240ms Optional Add on Timer 260ms Option...

Страница 159: ...g the linear EAN UPC part For UPC EAN add ons other than those of this type see Option al Add On Timer on page 146 ENTER EXIT PROGRAMMING MODE DEFAULT Optional GS1 128 Add On Timer Disable Optional GS...

Страница 160: ...28 Add On Timer cont ENTER EXIT PROGRAMMING MODE Optional GS1 128 Add On Timer 60ms Optional GS1 128 Add On Timer 70ms Optional GS1 128 Add On Timer 100ms Optional GS1 128 Add On Timer 120ms Optional...

Страница 161: ...t ENTER EXIT PROGRAMMING MODE Optional GS1 128 Add On Timer 180ms Optional GS1 128 Add On Timer 200ms Optional GS1 128 Add On Timer 220ms Optional GS1 128 Add On Timer 240ms Optional GS1 128 Add On Ti...

Страница 162: ...feature specifies the minimum number of times a P2 add on must be read before it is marked as valid and then combined with a base label ENTER EXIT PROGRAMMING MODE P2 Add Ons Minimum Reads 1 P2 Add On...

Страница 163: ...feature specifies the minimum number of times a P5 add on must be read before it is marked as valid and then combined with a base label ENTER EXIT PROGRAMMING MODE DEFAULT P5 Add Ons Minimum Reads 1 P...

Страница 164: ...cifies the minimum number of times an GS1 128 add on must be read before it is marked as valid and then combined with a base label ENTER EXIT PROGRAMMING MODE DEFAULT GS1 128 Add Ons Minimum Reads 1 G...

Страница 165: ...l not read GS1 DataBar Omnidirectional bar codes ENTER EXIT PROGRAMMING MODE DEFAULT GS1 DataBar Omnidirectional Disable GS1 DataBar Omnidirectional Enable GS1 DataBar Omnidirectional GS1 128 Emulatio...

Страница 166: ...e minimum number of consecutive times a GS1 DataBar Omni directional label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE DEFAULT GS1 DataBar Omnidirectional Minimum Re...

Страница 167: ...the reader will not read GS1 DataBar Expanded bar codes ENTER EXIT PROGRAMMING MODE DEFAULT GS1 DataBar Expanded Disable GS1 DataBar Expanded Enable GS1 DataBar Expanded GS1 128 Emulation When enabled...

Страница 168: ...pecifies the minimum number of consecutive times a GS1 DataBar Ex panded label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE DEFAULT GS1 DataBar Expanded Minimum Reads...

Страница 169: ...gth decoding or fixed length decoding for the GS1 DataBar Expanded symbology Variable Length For variable length decoding a minimum length may be set Fixed Length For fixed length decoding two differe...

Страница 170: ...EXPANDED LENGTH 1 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the length setting which was determined in the steps above You will hear a two beep ind...

Страница 171: ...GS1 DataBar Expanded Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select GS1 DataBar Expanded Set Length 1 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You...

Страница 172: ...e bar code SELECT GS1 DataBar EXPANDED LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the length setting which was determined in the steps above...

Страница 173: ...GS1 DataBar Expanded Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select GS1 DataBar Expanded Set Length 2 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You c...

Страница 174: ...ader will not read GS1 DataBar Limited bar codes ENTER EXIT PROGRAMMING MODE DEFAULT GS1 DataBar Limited Disable GS1 DataBar Limited Enable GS1 DataBar Limited GS1 128 Emulation When enabled GS1 DataB...

Страница 175: ...feature specifies the minimum number of consecutive times a GS1 DataBar Limited label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE DEFAULT GS1 DataBar Limited Minimum...

Страница 176: ...can TM QD2100 Code 39 The following options apply to the Code 39 symbology Code 39 Enable Disable When disabled the reader will not read Code 39 bar codes ENTER EXIT PROGRAMMING MODE Code 39 Disable C...

Страница 177: ...bled any check character in the label is treated as a data char acter ENTER EXIT PROGRAMMING MODE DEFAULT Code 39 Check Character Calculation Don t Calculate Code 39 Check Character Calculation Calcul...

Страница 178: ...RAMMING MODE Code 39 Check Character Transmission Don t Send Code 39 Check Character Transmission Send DEFAULT Code 39 Start Stop Character Transmission Enable this option to enable disable transmissi...

Страница 179: ...Code 39 cont Code 39 Full ASCII In Code 39 decoding this enables disables the translation of Code 39 characters to Code 39 full ASCII characters ENTER EXIT PROGRAMMING MODE DEFAULT Code 39 Full ASCII...

Страница 180: ...as at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label ENTER EXIT PROGRAMMING MODE Code 39 Quiet Zones Quiet Zone on one side Code 39 Quiet Zones...

Страница 181: ...eads This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Code 39 Minimum Reads 1 Code 39 Minim...

Страница 182: ...of decoding errors Choosing Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to change the decoding level for a parti...

Страница 183: ...erence Guide 173 Code 39 cont Code 39 Decoding Level cont ENTER EXIT PROGRAMMING MODE Code 39 Decoding Level 1 Code 39 Decoding Level 2 Code 39 Decoding Level 3 Code 39 Decoding Level 4 Code 39 Decodi...

Страница 184: ...ing or fixed length decoding for the Code 39 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths...

Страница 185: ...H 1 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the length setting which was determined in the steps above You will hear a two beep indi cation after...

Страница 186: ...de 39 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Code 39 Set Length 1 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the b...

Страница 187: ...MODE bar code to enter Programming Mode 3 Scan the bar code SELECT CODE 39 LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the length setting whi...

Страница 188: ...Code 39 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Code 39Length 2 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the begi...

Страница 189: ...specifies the ratio between an intercharacter space and module for Code 39 labels ENTER EXIT PROGRAMMING MODE Code 39 Interdigit Ratio Disable Code 39 Interdigit Ratio 1 Code 39 Interdigit Ratio 2 Co...

Страница 190: ...Scan TM QD2100 Code 39 cont Code 39 Interdigit Ratio cont ENTER EXIT PROGRAMMING MODE Code 39 Interdigit Ratio 6 Code 39 Interdigit Ratio 7 Code 39 Interdigit Ratio 8 Code 39 Interdigit Ratio 9 Code 3...

Страница 191: ...scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will also increa...

Страница 192: ...When parts of a Code 39 bar code are presented to the reader with this feature enabled the bar code parts will be as sembled by the reader s software and the data will be decoded if all bar code proof...

Страница 193: ...e 32 bar codes ENTER EXIT PROGRAMMING MODE DEFAULT Code 32 Disable Code 32 Enable Code 32 Feature Setting Exceptions NOTE The following features are set for Code 32 by using these Code 39 set tings Co...

Страница 194: ...ENTER EXIT PROGRAMMING MODE DEFAULT Code 32 Check Character Transmission Don t Send Code 32 Check Character Transmission Send Code 32 Start Stop Character Transmission This option enables disable tra...

Страница 195: ...ble Disable Enables Disables ability of the reader to decode Code 39 CIP labels ENTER EXIT PROGRAMMING MODE DEFAULT Code 39 CIP Disable Code 39 CIP Enable Code 128 The following options apply to the C...

Страница 196: ...els ENTER EXIT PROGRAMMING MODE DEFAULT Code 128 to Code 39 Don t Expand Code 128 to Code 39 Expand Code 128 Check Character Transmission Enable this option to transmit the check character along with...

Страница 197: ...t Code 128 Function Character Transmission Enables disables transmission of Code128 function characters 1 2 3 and 4 ENTER EXIT PROGRAMMING MODE DEFAULT Code 128 Function Character Transmission Don t S...

Страница 198: ...Sub Code Change Transmission Enables disables the transmission of Sub Code exchange characters NOT transmitted by standard decoding ENTER EXIT PROGRAMMING MODE DEFAULT Code 128 Sub Code Change Transmi...

Страница 199: ...lank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label ENTER EXIT PROGRAMMING MODE Code 128 Quiet Zones No Quiet Zones Code 128 Quiet Zone...

Страница 200: ...ds This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE DEFAULT Code 128 Minimum Reads 1 Code...

Страница 201: ...e of increasing the likelihood of decoding errors Choosing Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to change...

Страница 202: ...can TM QD2100 Code 128 cont Code 128 Decoding Level cont ENTER EXIT PROGRAMMING MODE Code 128 Decoding Level 1 Code 128 Decoding Level 2 Code 128 Decoding Level 3 Code 128 Decoding Level 4 Code 128 De...

Страница 203: ...ing or fixed length decoding for the Code 128 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different length...

Страница 204: ...TH 1 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the length setting which was determined in the steps above You will hear a two beep indi cation after...

Страница 205: ...de 128 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Code 128 Set Length 1 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the...

Страница 206: ...ode 3 Scan the bar code SELECT CODE 128 LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the length setting which was determined in the steps abov...

Страница 207: ...ode 128 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Code 128 Length 2 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the be...

Страница 208: ...scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will also increa...

Страница 209: ...labels When parts of a Code 128 bar code are presented to the reader with this feature enabled the bar code parts will be assembled by the reader s software and the data will be decoded if all bar co...

Страница 210: ...es the ability of the reader to translate GS1 128 labels to the GS1 128 data format Options are Transmit GS1 128 labels in Code 128 data format Transmit GS1 128 labels in GS1 128 data format Do not tr...

Страница 211: ...e Guide 201 Interleaved 2 of 5 I 2 of 5 The following options apply to the I 2 of 5 symbology I 2 of 5 Enable Disable When disabled the reader will not read I 2 of 5 bar codes ENTER EXIT PROGRAMMING M...

Страница 212: ...OGRAMMING MODE DEFAULT I 2 of 5 Check Character Calculation Disable I 2 of 5 Check Character Calculation Check Standard Modulo 10 I 2 of 5 Check Character Calculation Check German Par cel I 2 of 5 Che...

Страница 213: ...2 of 5 Check Character Transmission Enable this option to transmit the check character along with I 2 of 5 bar code data ENTER EXIT PROGRAMMING MODE I 2 of 5 Check Character Transmission Don t Send I...

Страница 214: ...nimum Reads This feature specifies the minimum number of consecutive times an I 2 of 5 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE I 2 of 5 Minimum Reads 1 I 2...

Страница 215: ...allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors Choosing Level 3 which is the default setting allows the majority of product labels...

Страница 216: ...TM QD2100 Interleaved 2 of 5 I 2 of 5 cont 2 of 5 Decoding Level cont ENTER EXIT PROGRAMMING MODE 2 of 5 Decoding Level 1 2 of 5 Decoding Level 2 2 of 5 Decoding Level 3 2 of 5 Decoding Level 4 2 of 5...

Страница 217: ...riable length decoding or fixed length decoding for the I 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding t...

Страница 218: ...T I 2 of 5 LENGTH 1 SETTING 5 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the length setting which was determined in the steps above You will hear a two beep in...

Страница 219: ...I 2 of 5 cont Datalogic 2 of 5 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select I 2 of 5 Length 1 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can th...

Страница 220: ...ing Mode 4 Scan the bar code SELECT I 2 of 5 LENGTH 2 SETTING 5 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the length setting which was determined in the steps...

Страница 221: ...f 5 I 2 of 5 cont I 2 of 5 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select I 2 of 5 Length 2 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then st...

Страница 222: ...m multiple scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will a...

Страница 223: ...ching for I 2 of 5 labels When parts of a I 2 of 5 bar code are presented to the reader with this feature enabled the bar code parts will be assembled by the reader s software and the data will be dec...

Страница 224: ...to decode Interleaved 2 of 5 CIP HR labels ENTER EXIT PROGRAMMING MODE DEFAULT Interleaved 2 of 5 CIP HR Disable Interleaved 2 of 5 CIP HR Enable Datalogic 2 of 5 The following options apply to the D...

Страница 225: ...of 5 Check Character Calculation This option enables disables calculation and verification of an optional Datalogic 2 of 5 check character ENTER EXIT PROGRAMMING MODE DEFAULT Datalogic 2 of 5 Check Ch...

Страница 226: ...imes an Datalogic 2 of 5 la bel must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE I 2 of 5 Minimum Reads 1 I 2 of 5 Minimum Reads 2 DEFAULT I 2 of 5 Minimum Reads 3 I 2 of...

Страница 227: ...ing or fixed length decoding for the Da talogic 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two differe...

Страница 228: ...of 5 LENGTH 1 SETTING 5 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the length setting which was determined in the steps above You will hear a two beep indi ca...

Страница 229: ...Datalogic 2 of 5 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Datalogic 2 of 5 Length 1 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then star...

Страница 230: ...4 Scan the bar code SELECT Datalogic 2 of 5 LENGTH 2 SETTING 5 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the length setting which was determined in the steps...

Страница 231: ...atalogic 2 of 5 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Datalogic 2 of 5 Length 2 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start...

Страница 232: ...pace and module for Datalogic 2 of 5 ENTER EXIT PROGRAMMING MODE Datalogic 2 of 5 Interdigit Maximum Ratio Disable Datalogic 2 of 5 Interdigit Maximum Ratio 1 Datalogic 2 of 5 Interdigit Maximum Ratio...

Страница 233: ...of 5 Interdigit Maximum Ratio 7 Datalogic 2 of 5 Interdigit Maximum Ratio 8 Datalogic 2 of 5 Interdigit Maximum Ratio 9 Datalogic 2 of 5 Interdigit Maximum Ratio 10 Datalogic 2 of 5 Product Reference...

Страница 234: ...multiple scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will als...

Страница 235: ...f 5 labels When parts of a Data logic 2 of 5 bar code are presented to the reader with this feature enabled the bar code parts will be assembled by the reader s software and the data will be decoded i...

Страница 236: ...can TM QD2100 Codabar The following options apply to the Codabar symbology Codabar Enable Disable When disabled the reader will not read Codabar bar codes ENTER EXIT PROGRAMMING MODE DEFAULT Codabar D...

Страница 237: ...cation of an optional Cod abar check character When disabled any check characters in the label are treated as data character ENTER EXIT PROGRAMMING MODE DEFAULT Codabar Check Character Calculation Don...

Страница 238: ...RAMMING MODE Codabar Check Character Transmission Don t Send Codabar Check Character Transmission Send DEFAULT Codabar Start Stop Character Transmission Enable this option to enable disable transmissi...

Страница 239: ...ter Set This option specifies the format of transmitted Codabar start stop characters ENTER EXIT PROGRAMMING MODE Codabar Check Character Set ABCD TN E Codabar Check Character Set ABCD ABCD Codabar Ch...

Страница 240: ...t Codabar Start Stop Character Match When enabled this option requires that start and stop characters match ENTER EXIT PROGRAMMING MODE DEFAULT Codabar Start Stop Character Match Don t Require Match C...

Страница 241: ...as at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label ENTER EXIT PROGRAMMING MODE Codabar Quiet Zones Quiet Zone on one side Codabar Quiet Zones...

Страница 242: ...eads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Codabar Minimum Reads 1 Codabar Minim...

Страница 243: ...of increasing the likelihood of decoding errors Choosing Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to change...

Страница 244: ...ckScan TM QD2100 Codabar cont Codabar Decoding Level cont ENTER EXIT PROGRAMMING MODE Codabar Decoding Level 1 Codabar Decoding Level 2 Codabar Decoding Level 3 Codabar Decoding Level 4 Codabar Decodi...

Страница 245: ...ing or fixed length decoding for the Codabar symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths...

Страница 246: ...SELECT CODABAR LENGTH 1 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the length setting which was determined in the steps above You will hear a two bee...

Страница 247: ...Codabar Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Codabar Length 1 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beg...

Страница 248: ...to enter Programming Mode 3 Scan the bar code SELECT CODABAR LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the length setting which was determi...

Страница 249: ...Codabar Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select CodabarLength 2 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the begi...

Страница 250: ...specifies the ratio between an intercharacter space and module for Codabar labels ENTER EXIT PROGRAMMING MODE Codabar Interdigit Ratio Disable Codabar Interdigit Ratio 1 Codabar Interdigit Ratio 2 Co...

Страница 251: ...ence Guide 241 Codabar cont Codabar Interdigit Ratio cont ENTER EXIT PROGRAMMING MODE Codabar Interdigit Ratio 6 Codabar Interdigit Ratio 7 Codabar Interdigit Ratio 8 Codabar Interdigit Ratio 9 Codaba...

Страница 252: ...scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will also increa...

Страница 253: ...labels When parts of a Codabar bar code are presented to the reader with this feature enabled the bar code parts will be as sembled by the reader s software and the data will be decoded if all bar cod...

Страница 254: ...es Disables ability of reader to decode ABC Codabar labels ENTER EXIT PROGRAMMING MODE DEFAULT ABC Codabar Disable ABC Codabar Enable ABC Codabar Concatenation Mode Specifies the concatenation mode be...

Страница 255: ...Dynamic Con catenation Mode ENTER EXIT PROGRAMMING MODE ABC Codabar Dynamic Concatenation Timeout 50 msec ABC Codabar Dynamic Concatenation Timeout 100 msec DEFAULT ABC Codabar Dynamic Concatenation T...

Страница 256: ...QD2100 ABC Codabar cont ABC Codabar Force Concatenation Forces labels starting or ending with D to be concatenated ENTER EXIT PROGRAMMING MODE DEFAULT ABC Codabar Force Concatenation Disable ABC Codab...

Страница 257: ...nce Guide 247 Code 11 The following options apply to the Code 11 symbology Code 11 Enable Disable When disabled the reader will not read Code 11 bar codes ENTER EXIT PROGRAMMING MODE DEFAULT Code 11 D...

Страница 258: ...ables disables calculation and verification of optional Code 11 check char acter ENTER EXIT PROGRAMMING MODE Code 11 Check Character Calculation Disable Code 11 Check Character Calculation Check C Cod...

Страница 259: ...t Code 11 Check Character Transmission This feature enables disables transmission of an optional Code 11 check character ENTER EXIT PROGRAMMING MODE Code 11 Check Character Transmission Don t Send Cod...

Страница 260: ...eads This feature specifies the minimum number of consecutive times a Code 11 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Code 11 Minimum Reads 1 Code 11 Minim...

Страница 261: ...ing or fixed length decoding for the Code 11 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different lengths...

Страница 262: ...G 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the length setting which was determined in the steps above You will hear a two beep indi cation after the last c...

Страница 263: ...de 11 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Code 11 Set Length 1 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the b...

Страница 264: ...n the bar code SELECT CODE 11 LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the length setting which was determined in the steps above You will...

Страница 265: ...ode 11 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Code 11 Length 2 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the begi...

Страница 266: ...specifies the ratio between an intercharacter space and module for Code 11 labels ENTER EXIT PROGRAMMING MODE Code 11 Interdigit Ratio Disable Code 11 Interdigit Ratio 1 Code 11 Interdigit Ratio 2 Co...

Страница 267: ...ence Guide 257 Code 11 cont Code 11 Interdigit Ratio cont ENTER EXIT PROGRAMMING MODE Code 11 Interdigit Ratio 6 Code 11 Interdigit Ratio 7 Code 11 Interdigit Ratio 8 Code 11 Interdigit Ratio 9 Code 1...

Страница 268: ...reasing the likelihood of decoding errors Choosing Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to change the dec...

Страница 269: ...erence Guide 259 Code 11 cont Code 11 Decoding Level cont ENTER EXIT PROGRAMMING MODE Codabar Decoding Level 1 Codabar Decoding Level 2 Codabar Decoding Level 3 Codabar Decoding Level 4 Codabar Decodi...

Страница 270: ...scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will also increa...

Страница 271: ...When parts of a Code 11 bar code are presented to the reader with this feature enabled the bar code parts will be as sembled by the reader s software and the data will be decoded if all bar code proof...

Страница 272: ...of 5 The following options apply to the Standard 2 of 5 symbology Standard 2 of 5 Enable Disable When disabled the reader will not read Standard 2 of 5 bar codes ENTER EXIT PROGRAMMING MODE DEFAULT S...

Страница 273: ...NTER EXIT PROGRAMMING MODE DEFAULT Standard 2 of 5 Check Character Calculation Disable Standard 2 of 5 Check Character Calculation Enable Standard 2 of 5 Check Character Transmission This feature enab...

Страница 274: ...ard 2 of 5 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Standard 2 of 5 Minimum Reads 1 Standard 2 of 5 Minimum Reads 2 DEFAULT Standard 2 of 5 Minimum Reads 3...

Страница 275: ...ing or fixed length decoding for the Standard 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two different...

Страница 276: ...OF 5 LENGTH 1 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the length setting which was determined in the steps above You will hear a two beep indi ca...

Страница 277: ...Standard 2 of 5 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Standard 2 of 5 Length 1 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start...

Страница 278: ...n the bar code SELECT STANDARD 2 OF 5 LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in Appendix E Keypad that represent the length setting which was determined in the steps above...

Страница 279: ...tandard 2 of 5 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Standard 2 of 5 Length 2 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start a...

Страница 280: ...scans when decoding Enabling correlation will help the scanner read labels that have some spots and or voids It may also help read labels that have damaged areas Enabling correlation will also increa...

Страница 281: ...When parts of a Stan dard 2 of 5 bar code are presented to the reader with this feature enabled the bar code parts will be assembled by the reader s software and the data will be decoded if all bar co...

Страница 282: ...ndustrial 2 of 5 labels ENTER EXIT PROGRAMMING MODE DEFAULT Industrial 2 of 5 Disable Industrial 2 of 5 Enable Industrial 2 of 5 Check Character Calculation Enables Disables calculation and verificati...

Страница 283: ...ont Industrial 2 of 5 Check Character Transmission Enables disables transmission of an Industrial 2 of 5 check character ENTER EXIT PROGRAMMING MODE Industrial 2 of 5 Check Character Transmission Disa...

Страница 284: ...oding or fixed length decoding for the In dustrial 2 of 5 symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two diff...

Страница 285: ...AL 2 of 5 LENGTH 1 SETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above You will hear a two beep i...

Страница 286: ...ial 2 of 5 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Industrial 2 of 5 Set Length 1 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start...

Страница 287: ...MING MODE bar code to enter Programming Mode 3 Scan the bar code SELECT INDUSTRIAL 2 OF 5 LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the l...

Страница 288: ...trial 2 of 5 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Industrial 2 of5 Length 2 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start ag...

Страница 289: ...eature specifies the minimum number of consecutive times an Industrial 2 of 5 la bel must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE DEFAULT Industrial 2 of 5 Minimum Re...

Страница 290: ...of 5 ENTER EXIT PROGRAMMING MODE DEFAULT Industrial 2 of 5 Stitching Disable Industrial 2 of 5 Stitching Enable Industrial 2 of 5 Character Correlation Enable disables character correlation for Indus...

Страница 291: ...he reader to decode IATA labels ENTER EXIT PROGRAMMING MODE DEFAULT IATA Disable IATA Enable IATA Check Character Transmission Enables Disables calculation and verification of an optional Industrial 2...

Страница 292: ...ISBT 128 The following options apply to the ISBT 128 symbology ISBT 128 Concatenation Enables disables ISBT128 concatenation of 2 labels ENTER EXIT PROGRAMMING MODE DEFAULT ISBN 128 Concatenation Dis...

Страница 293: ...on Mode Specifies the concatenation mode between Static and Dynamic ENTER EXIT PROGRAMMING MODE DEFAULT ISBT 128 Concatenation Mode Static ISBT 128 Concatenation Mode Dynamic NOTE This option is only...

Страница 294: ...oncatenation Mode ENTER EXIT PROGRAMMING MODE ISBT 128 Dynamic Concatenation Timeout 50 msec ISBT 128 Dynamic Concatenation Timeout 100 msec DEFAULT ISBT 128 Dynamic Concatenation Timeout 200 msec ISB...

Страница 295: ...TER EXIT PROGRAMMING MODE DEFAULT ISBT 128 Force Concatenation Disable ISBT 128 Force Concatenation Enable This option is only valid when ISBT 128 Concatenation is enabled see page 282 ISBT 128 Advanc...

Страница 296: ...286 QuickScan TM QD2100 MSI The following options apply to the MSI symbology MSI Enable Disable Enables Disables ability of reader to decode MSI labels ENTER EXIT PROGRAMMING MODE DEFAULT MSI Disable...

Страница 297: ...bles calculation and verification of an optional MSI check character ENTER EXIT PROGRAMMING MODE MSI Check Character Calculation Disable MSI Check Character Calculation Enable Mod10 DEFAULT MSI Check...

Страница 298: ...heck Character Transmission Enable DEFAULT MSI Length Control This feature specifies either variable length decoding or fixed length decoding for the MSI symbology Variable Length For variable length...

Страница 299: ...4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above You will hear a two beep indi cation after the last...

Страница 300: ...MSI Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select MSI Set Length 1 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginni...

Страница 301: ...r code to enter Programming Mode 3 Scan the bar code SELECT MSI LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which was de...

Страница 302: ...MSI Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select MSI Length 2 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the beginning...

Страница 303: ...m Reads This feature specifies the minimum number of consecutive times an MSI label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE MSI Minimum Reads 1 MSI Minimum Reads...

Страница 304: ...sing Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to change the decoding level for a particular symbology These f...

Страница 305: ...MSI Product Reference Guide 295 MSI cont MSI Decoding Level cont MSI Decoding Level 3 MSI Decoding Level 4 MSI Decoding Level 5 DEFAULT...

Страница 306: ...an TM QD2100 Plessey The following options apply to the Plessey symbology Plessey Enable Disable Enables Disables ability of reader to decode Plessey labels ENTER EXIT PROGRAMMING MODE DEFAULT Plessey...

Страница 307: ...Plessey check character ENTER EXIT PROGRAMMING MODE Plessey Check Character Calculation Disable Plessey Check Character Calculation Enable Plessey std check char verification DEFAULT Plessey Check Cha...

Страница 308: ...heck Character Transmission Enable DEFAULT PLessey Length Control This feature specifies either variable length decoding or fixed length decoding for the Plessey symbology Variable Length For variable...

Страница 309: ...ETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above You will hear a two beep indi cation after the...

Страница 310: ...essey Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Plessey Set Length 1 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the b...

Страница 311: ...bar code to enter Programming Mode 3 Scan the bar code SELECT PLESSEY LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which...

Страница 312: ...lessey Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Plessey Length 2 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the begi...

Страница 313: ...eads This feature specifies the minimum number of consecutive times a Plessey label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE Plessey Minimum Reads 1 Plessey Minim...

Страница 314: ...ng Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to change the decoding level for a particular symbology These fac...

Страница 315: ...ecoding Level cont Plessey Stitching Enables disables fixed length stitching for Plessey ENTER EXIT PROGRAMMING MODE DEFAULT Plessey Stitching Disable Plessey Stitching Enable Plessey Decoding Level 3...

Страница 316: ...sey ENTER EXIT PROGRAMMING MODE DEFAULT Plessey Character Correlation Disable Plessey Character Correlation Enable Code 93 The following options apply to the Code 93 symbology Code 93 Enable Disable E...

Страница 317: ...lculation and verification of an optional Code 93 check character ENTER EXIT PROGRAMMING MODE Code 93 Check Character Calculation Disable Code 93 Check Character Calculation Enable Check C Code 93 Che...

Страница 318: ...e 93 Check Character Transmission Enable DEFAULT Code 93 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 93 symbology Variable Length For va...

Страница 319: ...ETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above You will hear a two beep indi cation after the...

Страница 320: ...de 93 Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Code 93 Set Length 1 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the b...

Страница 321: ...bar code to enter Programming Mode 3 Scan the bar code SELECT CODE 93 LENGTH 2 SETTING 4 Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which...

Страница 322: ...ode 93 Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Code 93 Length 2 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the begi...

Страница 323: ...eads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE DEFAULT Code 93 Minimum Reads 1 Code...

Страница 324: ...ng Level 3 which is the default setting allows the majority of product labels to be decoded There are many factors that determine when to change the decoding level for a particular symbology These fac...

Страница 325: ...Code 93 Product Reference Guide 315 Code 93 cont Code 93 Decoding Level cont Code 93 Decoding Level 3 Code 93 Decoding Level 4 Code 93 Decoding Level 5 DEFAULT...

Страница 326: ...sables fixed length stitching for Code 93 ENTER EXIT PROGRAMMING MODE Code 93 Quiet Zones No Quiet Zones Code 93 Quiet Zones Quiet Zone on one side Code 93 Quiet Zones Quiet Zones on two sides Code 93...

Страница 327: ...th stitching for Code 93 ENTER EXIT PROGRAMMING MODE Code 93 Stitching Disable Code 93 Stitching Enable DEFAULT Code 93 Character Correlation Enables disables Character Correlation for Code 93 ENTER E...

Страница 328: ...ablock F The following options apply to the Codablock F symbology Codablock F Enable Disable Enables Disables the ability of the imager to decode Codablock F labels ENTER EXIT PROGRAMMING MODE DEFAULT...

Страница 329: ...subtype code with FNC1 in the first position ENTER EXIT PROGRAMMING MODE DEFAULT Codablock F EAN Disable Codablock F EAN Enable Codablock F AIM Check Specifies if Check Digit calculation algorithm is...

Страница 330: ...decoding or fixed length decoding for the Codablock F symbology Variable Length For variable length decoding a minimum and maximum length may be set Fixed Length For fixed length decoding two differe...

Страница 331: ...SETTING 4 Scan the appropriate three digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above You will hear a two beep indi cation after...

Страница 332: ...ablock F Set Length 1 cont ENTER EXIT PROGRAMMING MODE Select Codablock F Length 1 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at th...

Страница 333: ...r code to enter Programming Mode 3 Scan the bar code SELECT CODABLOCK F LENGTH 2 SETTING 4 Scan the appropriate three digits from the keypad in the Keypad Appendix that represent the length setting wh...

Страница 334: ...block F Set Length 2 cont ENTER EXIT PROGRAMMING MODE Select Codablock F Length 2 Setting Make a mistake Scan the CANCEL bar code to abort and not save the entry string You can then start again at the...

Страница 335: ...ence Guide 325 Code 4 The following options apply to the Code 4 symbology Code 4 Enable Disable Enables Disables ability of imager to decode Code 4 labels ENTER EXIT PROGRAMMING MODE DEFAULT Code 4 Di...

Страница 336: ...NTER EXIT PROGRAMMING MODE Code 4 Check Character Transmission Don t Send Code 4 Check Character Transmission Send DEFAULT Code 4 Hex to Decimal Conversion This feature enables disables the conversion...

Страница 337: ...ence Guide 327 Code 5 The following options apply to the Code 5 symbology Code 5 Enable Disable Enables Disables ability of imager to decode Code 5 labels ENTER EXIT PROGRAMMING MODE DEFAULT Code 5 Di...

Страница 338: ...NTER EXIT PROGRAMMING MODE Code 5 Check Character Transmission Don t Send Code 5 Check Character Transmission Send DEFAULT Code 5 Hex to Decimal Conversion This feature enables disables the conversion...

Страница 339: ...printed and damaged labels at the expense of increasing the likelihood of decoding errors Choosing Level 3 which is the default setting allows the majority of product labels to be decoded There are ma...

Страница 340: ...iguration Items cont Code 4 and 5 Decoding Level cont ENTER EXIT PROGRAMMING MODE Code 4 and Code 5 Decoding Level 1 Code 4 and Code 5 Decoding Level 2 Code 4 and Code 5 Decoding Level 3 Code 4 and Co...

Страница 341: ...nd Code 5 Minimum Reads This feature specifies the minimum number of consecutive times a Code 4 or Code 5 label must be decoded before it is accepted as good read ENTER EXIT PROGRAMMING MODE DEFAULT C...

Страница 342: ...2 of 5 The following options apply to the Follett 2 of 5 symbology Follett 2 of 5 Enable Disable Enables Disables ability of imager to decode Follett 2 of 5 labels ENTER EXIT PROGRAMMING MODE DEFAULT...

Страница 343: ...thout cable Approximately 4 2 oz 119 g Color Black or White Electrical Characteristics Voltage Current QD2110 4 14 VDC QD2130 5 0 VDC 10 180mA 5V Typical Idle 345mA 5V Typical Scanning Performance Cha...

Страница 344: ...2x VT3xx and VT4xx User Environment Operating Temperature 32 to 122 F 0 to 50 C Storage Temperature 40 to 158 F 40 to 70 C Humidity 5 to 95 relative humidity non condensing Drop Specifications Withsta...

Страница 345: ...in Table 46 apply to the connector on the imager and are for ref erence only Table 46 Standard Cable Pinouts Imager Side Cable Clip Latch To Host Cable Cable Strain Relief Bottom of Imager Interface...

Страница 346: ...336 QuickScanTM QD2100 NOTES...

Страница 347: ...default settings for these same configurable features Table 47 Standard Defaults Parameter Default Your Setting Page Number General Features Double Read Timeout 0 4 Second 17 Label Gone Timeout 160 ms...

Страница 348: ...Retries 58 ACK NAK Error Handling Ignore Errors Detected 60 Indicate Transmission Failure Enable 61 Disable Character D 62 Enable Character E 64 Keyboard Wedge Country Mode U S Keyboard 68 Caps Lock S...

Страница 349: ...bal Prefix Global Suffix 0x0D CR 98 Global AIM ID Disable 100 Label ID Control Disable 108 Case Conversion Disable 117 Character Conversion No Char Conver sion 118 Symbologies Coupon Control Enable on...

Страница 350: ...ble Disable Disable 134 EAN 13 Minimum Reads 1 135 EAN 8 EAN 8 Enable Disable Enable 136 EAN 8 Check Character Transmis sion Send 136 Expand EAN 8 to EAN 13 Disable 137 EAN 8 Minimum Reads 1 138 UPC E...

Страница 351: ...l Variable 159 GS1 DataBar Expanded Set Length 1 1 160 GS1 DataBar Expanded Set Length 2 74 162 GS1 DataBar Limited GS1 DataBar Limited Enable Disable Disable 164 GS1 DataBar Limited GS1 128 Emu latio...

Страница 352: ...it 184 Code 39 CIP Code 39 CIP Enable Disable Disable 185 Code 128 Code 128 Enable Disable Enable 185 Expand Code 128 to Code 39 Don t Expand 186 Code 128 Check Character Trans mission Send 186 Code 1...

Страница 353: ...able Enable 214 Datalogic 2 of 5 Check Character Calculation Disable 215 Datalogic 2 of 5 Minimum Reads 2 216 Datalogic 2 of 5 Length Control Variable 217 Datalogic 2 of 5 Set Length 1 12 218 Datalogi...

Страница 354: ...C Codabar Dynamic Concatena tion Timeout 200mS 245 ABC Codabar Force Concatenation Disable 246 Code 11 Code 11 Enable Disable Disable 247 1 247 Code 11 Check Character Calcula tion Check C and K 248 C...

Страница 355: ...ial 2 of 5 Check Character Calculation Disable 272 Industrial 2 of 5 Check Character Transmission Enable 273 Industrial 2 of 5 Length Control Variable 274 Industrial 2 of 5 Set Length 1 1 Character 27...

Страница 356: ...on Enable Plessey Std Check Char Verif 297 Plessey Check Character Transmis sion Enable 298 PLessey Length Control Variable 298 Plessey Set Length 1 1 Character 299 Plessey Set Length 2 50 Characters...

Страница 357: ...Codablock F Set Length 1 3 Characters 321 Codablock F Set Length 2 100 Characters 323 Code 4 Code 4 Enable Disable Disable 325 Code 4 Check Character Transmis sion Enable 326 Code 4 Hex to Decimal Co...

Страница 358: ...heck Character Transmission Disable Parity Odd Parity Handshaking Control RTS CTS Transmission Label ID Code Prefix GS1 128 AIM ID Disable UPCE Label ID Character s C EAN 8 Label ID Character s B EAN...

Страница 359: ...EAN 8 Label ID Character s A EAN 13 Label ID Character s B Code ISBN Label ID Character s Code 39 Label ID Character s V Code 32 Label ID Character s X Interelaved 2of5 Label ID Character s N Code Sta...

Страница 360: ...4 Omnidirectional Label ID Character s u GS1 DataBar Expanded Label ID Character s t GS1 DataBar Limited Label ID Character s v GTIN W o Add on Label ID Character s A GTIN Addon 2 Label ID Character s...

Страница 361: ...rors on the imager An optional Green Spot also performs useful functions The tables below list these indications One exception to the behaviors listed in the tables is that the imager s functions are...

Страница 362: ...e the green spot shall be on while in stand watch state N A N A Green Spota flashes momen tarily Upon successful read of a label the software shall turn the green spot on for the time specified by the...

Страница 363: ...FRU1 isolation mode If the imager is reset the se quence will be repeated The following table describes the LED flashes beep codes asso ciated with an error found 1 Configuration Contact Helpdesk for...

Страница 364: ...354 QuickScanTM QD2100 NOTES...

Страница 365: ...r codes in this appendix are typical representations for their symbology types UPC A EAN 13 Code 39 Code 128 Interleaved 2 of 5 0 12345 67890 5 3 456789 012340 123ABC 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7...

Страница 366: ...356 QuickScanTM QD2100 Sample bar codes continued Code 32 Codabar Code 93 Code 11...

Страница 367: ...taBar RSS on page 357 GS1 DataBar 14 10293847560192837465019283746029478450366523 GS1 DataBar Expanded Stacked 1234890hjio9900mnb GS1 DataBar Expanded 08672345650916 GS1 DataBar Limited 55432198673467...

Страница 368: ...358 QuickScanTM QD2100 NOTES...

Страница 369: ...Product Reference Guide 359 Appendix E Keypad Use the bar codes in this appendix to enter numbers as you would select digits characters from a keypad 0 1 2 3 4 5...

Страница 370: ...360 QuickScanTM QD2100 6 7 8 9 A B C...

Страница 371: ...Product Reference Guide 361 D E F...

Страница 372: ...362 QuickScanTM QD2100 NOTES...

Страница 373: ...dge and USB Keyboard platforms Control Character 00 Characters from 00 to 0x1F are sent as control character Ctrl Keys special keys are located from 0x80 to 0xA1 Control Character 01 Characters from 0...

Страница 374: ...EOT C D ENQ C S E ACK C S F BEL C S G BS C S H HT TAB LF C S J VT C S K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S...

Страница 375: ...X6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I...

Страница 376: ...A 091 A 092 A 093 A 094 A 095 6x A 096 A 097 A 098 A 099 A 100 A 101 A 102 A 103 A 104 A 105 A 106 A 107 A 108 A 109 A 110 A 111 7x A 112 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A...

Страница 377: ...12 A 113 A 114 A 115 A 116 A 117 A 118 A 119 A 120 A 121 A 122 A 123 A 124 A 125 A 126 A 127 8x A 0128 A 0129 A 0130 A 0131 A 0132 A 0133 A 0134 A 0135 A 0136 A 0137 A 0138 A 0139 A 0140 A 0141 A 0142...

Страница 378: ...AB LF C S J VT C S K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS C RS C S US C...

Страница 379: ...er is 02 X0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Cl Cl BS Tab S Tab Enter Keypd Enter Ins 1x F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G H I J K L M...

Страница 380: ...Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS C RS C S US C S _ 2x Space 3x 0 1 2 3 4 5 6 7...

Страница 381: ...3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E...

Страница 382: ...K FF C S L CR Enter SO C S N SI C S O 1x DLE C S P DC1 C S Q DC2 C S R DC3 C S S DC4 C S T NAK C S U SYN C S V ETB C S W CAN C S X EM C S Y SUB C S Z ESC Esc FS C S GS C RS C S US C S _ 2x Space 3x 0...

Страница 383: ...x5 x6 x7 x8 x9 xA xB xC xD xE xF 0x Ar Ar Al Al Cl Cl Cr Cr BS Tab S Tab Enter Keypd Enter Ins Pg Up 1x Pg Dwn Home F6 F1 F2 F3 F4 F5 ESC F7 F8 F9 F10 2x Space 3x 0 1 2 3 4 5 6 7 8 9 4x A B C D E F G...

Страница 384: ...canTM QD2100 Microsoft Windows Codepage 1252 Windows 1252 is a character encoding of the Latin alphabet used by default in the leg acy components of Microsoft Windows in English and some other Western...

Страница 385: ...ity 334 Defaults 337 Depth of Field 333 E eading trailing noise 95 Electrical Safety 334 EMI RFI 334 Error Codes 353 Errors 353 G Good Read Beeper 21 Pitch 23 24 Volume 26 Good Read Beeper 21 Good Rea...

Страница 386: ...eeper Volume Good 26 Request to Send 46 Roll Tilt Tolerance 333 RS 232 interface selection 12 RS 232 Serial Connection 6 RTS 46 S sample bar codes code 128 355 code 39 355 interleaved 2 of 5 356 selec...

Страница 387: ...SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP 0 1 2 3 4 5 6 7 8 9 20 21 22 23 24 25...

Страница 388: ...alogic ADC Inc All rights reserved Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U Datalogic ADC Inc 959 Terry Street Eu...

Отзывы: