background image

Technical Specifications

22

PowerScan™ PD953X

Decode Capability

1D Bar Codes

 

GS1 Databar linear codes, UPC/EAN (A,E,13,8), UPC/EAN with P2/
P5 Addons, UPC/EAN Coupons, ISBN, Code128, EAN128, ISBT128, 
Code39, Code39 Full ASCII, Code39 CIP, Code 32, Codabar, Inter-
leaved 2 of 5, IATA, Industrial 2 of 5, Standard 2 of 5, Code11, MSI, 
Plessey, Code 93, Follet 2/5

2D / Stacked Codes

 

DataMatrix, MaxiCode and QR Codes(QR, Micro QR and Multiple QR 
codes), Aztec
- Postal codes including:
 Australian Post, China Post, Japanese Post, KIX Post, Planet Code, 
Postnet, Royal Mail Code(RM45CC), IMB 
- stacked codes including EAN/JAN Composites; GS1 Databar Com-
posites, GS1 Databar Expanded Stacked; GS1 DataBar Stacked; GS1 
DataBar Stacked Omnidirectional; MacroPDF; Micro PDF417; 
PDF417; UPC A/E Composites, French CIP13, Grid Matrix(Chinese) 
code

Interfaces Supported

RS-232, Keyboard Wedge, and USB. 
See page 5 for a listing of available inter-
face options. 

User Environment

Operating Tempera-
ture

-4° to 122° F (-20°   -   +50° C )

Storage Temperature

-40° to 158° F (-40° to 70° C)

Humidity 

0 to 95% non-condensing

Drop Specifications

Scanner withstands >50 times 6.5' (2 m)  
drops to concrete

Ambient Light Immu-
nity 

100,000 Lux 

Contaminants: Spray/
rain, 
Dust/particulates

IP65

ESD Level

20 KV

Beeper/Speaker

>= 80 dB  @ 10 cm 

Regulatory

See Regulatory Addendum

Содержание PowerScan PD953X

Страница 1: ...PowerScan PD953X Industrial Corded Handheld Area Imager Bar Code Reader Quick Reference Guide...

Страница 2: ...u can acquire printed versions by contacting your Datalogic repre sentative Electronic versions may either be downloadable from the Datalogic website www datalogic com or provided on appropriate media...

Страница 3: ...8 Keyboard Interface 8 Country Mode 9 Caps Lock State 13 Numlock 14 Programming 15 Using Programming Bar Codes 15 Configure Other Settings 15 Resetting Product Defaults 15 Reading Parameters 16 Good...

Страница 4: ...ii PowerScan PD953X...

Страница 5: ...e shall mean acquire under license End User is not entitled to receipt or use of the source code of any licensed Software 1 4 Portions of the Datalogic Product are protected by the relevant and applic...

Страница 6: ...any and all claims actions suits or pro ceedings as well as any and all losses liabilities damages costs and expenses including reasonable attorney s fees arising out of or accruing from or related to...

Страница 7: ...ion of the laws of the country in which End User obtained the license to govern interpret and enforce all of End User s and Datalogic s respective rights duties and obligations arising from or relatin...

Страница 8: ...therwise fails to appoint an arbitrator within 30 days of the date the other party appoints its the first appointed arbitrator will be the sole arbitrator provided that the arbi trator was validly and...

Страница 9: ...sity codes DPM laser ink jet and dot peen Omni directional Operating To read a symbol or capture an image you simply aim the reader and pull the trigger Since the PowerScan PD953X is a powerful omni d...

Страница 10: ...owerScan PD953X can also function as a camera by capturing entire images or image portions of labels signatures and other items Autoscanning An autoscan command causes the reader to scan continuously...

Страница 11: ...the Front marking on the Cable Holder is facing out with the arrow pointing towards the front of the scanner 4 Insert the end of the cable into the socket of the Cable Holder 5 Push the Cover along th...

Страница 12: ...tem will be smaller when the reader is closer to the bar code and larger when it is farther from the code Symbologies with smaller bars or elements mil size should be read closer to the unit Symbologi...

Страница 13: ...ovided in this section For defaults and addi tional information associated with each interface proceed to the corresponding chapter in the PowerScan 9500 Family PRG Configuring the Interface Scan the...

Страница 14: ...Interface Type 6 PowerScan PD953X RS 232 RS 232 standard interface RS 232 RS 232 Wincor Nixdorf RS232 WN RS 232 for use with OPOS UPOS JavaPOS RS 232 OPOS USB USB Com to simulate RS 232 standard inter...

Страница 15: ...ued USB OEM can be used for OPOS UPOS JavaPOS USB OEM a Download the correct USB Com driver from www datalogic com USB Keyboard with standard key encoding USB KBD USB Keyboard with alternate key encod...

Страница 16: ...character emulation for keyboard interfaces Keyboard Interface KEYBOARD WEDGE IBM AT or PS 2 PCs Standard Key Encoding KBD AT IBM AT or PS 2 PCs Standard Key Encoding without external keyboard KBD AT...

Страница 17: ...ted by the keyboard This option is usable only with USB KBD and Keyboard Wedge interface without the Alternate Key mode COUNTRY MODE ENTER EXIT PROGRAMMING MODE Country Mode U S Country Mode Belgium C...

Страница 18: ...an PD953X COUNTRY MODE continued Country Mode Czech Country Mode Denmark Country Mode France Country Mode French Canadian Country Mode Germany Country Mode Hungary Supports only the interfaces listed...

Страница 19: ...Guide 11 COUNTRY MODE continued Country Mode Italy Country Mode Japanese 106 key Country Mode Lithuanian Country Mode Norway Country Mode Poland Country Mode Portugal Supports only the interfaces lis...

Страница 20: ...e 12 PowerScan PD953X COUNTRY MODE continued Country Mode Romania Country Mode Spain Country Mode Sweden Country Mode Slovakia Country Mode Switzerland Supports only the interfaces listed in the Count...

Страница 21: ...the format in which the reader sends character data This applies to keyboard wedge interfaces This does not apply when an alternate key encoding key board is selected ENTER EXIT PROGRAMMING MODE Caps...

Страница 22: ...on specifies the setting of the Numbers Lock Numlock key while in keyboard wedge interface This only applies to alternate key encoding interfaces It does not apply to USB keyboard ENTER EXIT PROGRAMMI...

Страница 23: ...ar code once to enter Programming Mode scan the desired parameter settings scan the ENTER EXIT bar code again to accept your changes which exits Program ming Mode and returns the reader to normal oper...

Страница 24: ...si tion time and if no code is decoded will switch on again before the next acquisition The illuminator will remain on until the symbol is decoded As you read code symbols adjust the distance at which...

Страница 25: ...ts undesired multiple reads while in this mode Trigger Hold Multiple When the trigger is pulled scan ning starts and the product scans until the trigger is released or maximum scan on time 1 has elaps...

Страница 26: ...is detected Motionix motion sensing technology Scan the Enter Exit Programming bar code above then either of the barcodes below ENTER EXIT PROGRAMMING MODE Scan Mode Trigger Single Scan Mode Trigger...

Страница 27: ...or transmitted to the host It is active only while the scanner is in Trigger Single mode If the scanner switches to a different Read Mode Pick Mode is automatically dis abled Multiple Label Reading Th...

Страница 28: ...Description Physical Characteristics Dimensions Height 212 mm Length 110 mm Width 74 mm Weight without cable 330 gr without cable Electrical Characteristics Voltage Cur rent PD953X PD953X HP PD953X H...

Страница 29: ...tion 2D 7 5 mils 1D 2 5 mil 2D 4 mil Depth of Field Typical a Symbology Standard Model High Performance Code 39 4 mils 6 17 cm 20 mils 4 55 cm 40 mils 4 85 cm 2 5 mils 2 6 cm 20 mils 3 70 cm 40 mils 3...

Страница 30: ...Code RM45CC IMB stacked codes including EAN JAN Composites GS1 Databar Com posites GS1 Databar Expanded Stacked GS1 DataBar Stacked GS1 DataBar Stacked Omnidirectional MacroPDF Micro PDF417 PDF417 UPC...

Страница 31: ...r beeps four times at highest fre quency and vol ume upon power up Good Read Beep A label has been successfully scanned by the reader LED behavior for this indica tion is configu rable via the feature...

Страница 32: ...bel the soft ware shall turn the green spot on for the time specified by the configured value N A N A Image Cap ture When ready to capture image Blue light flashes 2 times when updating N A aExcept wh...

Страница 33: ...abel Pro gramming Mode Accep tance of Par tial Label In cases where multiple labels must be scanned to program one feature this indica tion acknowledges each portion as it is successfully scanned N A...

Страница 34: ...d Replaceable Unit isolation mode If the reader is reset the sequence will be repeated Press and release the trigger to hear the FRU indication code The following table describes the LED flashes beep...

Страница 35: ...ce during scanning Use a soft dry cloth to clean the product If the product is very soiled clean it with a soft cloth moistened with a diluted non aggressive cleaning solution or diluted ethyl alcohol...

Страница 36: ...ship and materials on the repaired assembly for a 90 day period starting from the date of shipment of the repaired product from Datalogic or until the expiration of the original warranty period whiche...

Страница 37: ...or viii any consumable or equivalent e g cables power supply batteries keypads touch screen triggers etc No Assignment Customer may not assign or otherwise transfer its rights or obliga tions under t...

Страница 38: ...support through its website Log on to www datalogic com and click on the SUPPORT link which gives you access to Downloads by selecting your product model from the dropdown list in the Search by Produc...

Страница 39: ......

Страница 40: ...Datalogic and the Datalogic logo are registered trademarks of Datalogic S p A in many countries including the U S A and the E U Datalogic USA Inc 959 Terry Street Eugene OR 97402 USA Telephone 541 68...

Отзывы: