Datalogic P2x-Series Скачать руководство пользователя страница 59

CALIBRATION

PRODUCT REFERENCE GUIDE   

51

CALIBRATION

VPM provides calibration software to insure that the measurements indicated in VPM
tools accurately relate to the inspected object’s measurements. You may calibrate a
camera using a calibrated target, a part with known dimensions, or you can enter the
camera’s units-per-pixel factor manually.

Refer to the Calibration Drawer section of the Impact Reference Guide for details.

PARTIAL SCAN

In order to satisfy very high throughput applications, higher frame rates can be achieved
using the powerful 

Partial Scan

 parameters in the Camera setup menu.

Partial Scan 

allows defining a region or window within the camera Field of View. The

Top and Bottom Edge parameters allow you to precisely define the image window to be
processed.

In the camera the frame rate is dependent on the number of lines (or rows) in the
defined window.

The smaller the window, the shorter the frame period, and consequently the higher the
frame rate. In general, the Image Processing time can be reduced by reducing the win-
dow dimensions.

Содержание P2x-Series

Страница 1: ...P2x Series P2x Series P2x Series P2X Series PRODUCT REFERENCE GUIDE Industrial Smart Camera...

Страница 2: ...aimer Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate how ever Datalogic shall not be liable for technical or editorial errors or omissions...

Страница 3: ...illuminators 7 Necessary camera components 8 Basic components 9 Accessories 9 CHAPTER 2 RAPID CONFIGURATION 11 STEP 1 Connect the system 11 CBX500 CBX800 Pinout for P2x Series 12 STEP 2 Install the le...

Страница 4: ...CONNECTIONS USING EXTERNAL POWER 42 OUTPUT 3 CONNECTIONS USING P2x Series POWER CBX500 Only 43 OUTPUT 3 CONNECTIONS USING EXTERNAL POWER CBX500 Only 43 OUTPUT 3 CONNECTIONS USING P2x Series POWER CBX...

Страница 5: ...a The symbols listed below are used in this manual to notify the reader of key issues or procedures that must be observed when using the reader TECHNICAL SUPPORT Support Through the Website Datalogic...

Страница 6: ...und for direct connections connect your cable shield to the locking ring nut of the connec tor CE Compliance CE marking states the compliance of the product with essential requirements listed in the a...

Страница 7: ...NG The P2x Series camera is designed to be used in an industrial environment and is built to withstand vibration and shock when correctly installed However it is also a precision product and it must b...

Страница 8: ...PREFACE viii P2X SERIES Do not weld the camera into position This can cause electrostatic heat or imager damage Do not spray paint near the camera This can cause lens or imager damage...

Страница 9: ...set Loader 9 Bracket Mounting Holes 4 3 Focus Adjustment Screws 4 10 Gigabit Ethernet Connection LED 4 Red Spot1 1 Not included in Configuration A External Lighting 11 Power Serial Interfaces I O Conn...

Страница 10: ...cket Mounting Holes 4 3 Lens 10 Gigabit Ethernet Connection LED 4 Focus Adjustment Screw on side 11 Gigabit Ethernet Connector 5 Red Spot 12 Power Serial Interfaces I O Connector 6 Green Spot 13 Power...

Страница 11: ...er Electrical connection of Power and I O signals is provided through an M12 IP67 17 pin connector A standard M12 IP67 Gigabit Ethernet connector is also present Rugged construction IP67 and IP65 prot...

Страница 12: ...nd Apply Food Beverage Label inspection Expiration Date Lot number T L Object detection The following diagrams list the operating distances for various cameras using a 14 LEDs illuminator or the space...

Страница 13: ...GENERAL VIEW PRODUCT REFERENCE GUIDE 5...

Страница 14: ...ower On camera is connected to power 2 ETH On Gigabit Ethernet link is established Blinking data trans mission 3 Busy LED blinks during task execution and flash memory access 4 Out 1 On Output 1 is on...

Страница 15: ...and Lens Notes for 14 and 36 LEDs illuminators The following table shows the lenses and illuminators for the P2x Series The blue checkbox indicates the recommended combinations the green check box in...

Страница 16: ...LEDs Illuminator 6 MM 8 MM 12 5 MM 17 5 MM Narrow Angle Lighting LTP 110 350 SN14L 35D RED 625nm LTP 112 350 SN36L 35D RED 625nm LTP 110 351 SN14L 35D WHT white LTP 112 351 SN36L 35D WHT white LTP 11...

Страница 17: ...andard LT 14L M320 P2 93ACC0271 Cover Standard LT 36L M320 P2 93ACC0272 Filters Filter Yag Cut LT 14L M320 P2 95A900018 Filter Yag Cut LT 36L M320 P2 95A900022 Lenses LNP 601 010 ML 6MM FF4 1 3 95A900...

Страница 18: ...D ADAPTER CAB GETH X to ETH D 93A050129 Bracket BK 32 000 STD FIX BRACKET M320 P2 BODY 93ACC0282 BK 32 010 PIVOT FIX BRACKET M320 P2 BODY 93ACC0283 Connectivity I O BOARD I O Board P A T Series Femal...

Страница 19: ...y for cam era and program configuration and inspection monitoring The Terminal Block is used to facilitate the connection between the camera external trigger and optional input and output devices Figu...

Страница 20: ...wer Source External Trigger O2 Output 2 I1A External Trigger A polarity insensi tive O3A CBX500 Strobe Output 3 Single Pin Connection I1B External Trigger B polarity insensi tive V Power Reference Ext...

Страница 21: ...he cover 2 To unmount the cover properly it is recommended to gently lever the cover from its corners using a flat blade screwdriver between the cover and the body of the reader CAUTION Disconnect pow...

Страница 22: ...h the corre spondent cover seat Figure 3 Aligning the cover 14 and 36 LEDs models 2 Place the new cover on the reader and press the cover frame edges NOTE Make sure the new cover is free of dust dirt...

Страница 23: ...the lens 90 counter clockwise 4 Lift the lens straight up until it clears the lens housing To replace the camera micro lens 1 Align the tabs on the lens with the notches in the lens housing 2 Grasp th...

Страница 24: ...rnal illuminator Two mounting options are available for the 36 LEDs Illuminator vertical or landscape position 1 Place the camera on a flat surface such as the illuminator side faces downwards Remove...

Страница 25: ...ly press straight down on the filter The filter is equipped with two pins at the bottom that guide its insertion into the product 4 Finally mount the cover back on the reader body See To replace the c...

Страница 26: ...st common mounting configurations are shown in the figures below 14 LEDs Illuminator Figure 4 14 LEDs Illuminator with STD Fix Bracket 36 LEDs Illuminator Position 1 Figure 5 36 LEDs Illuminator with...

Страница 27: ...with Pivot Fix Bracket Position 3 Figure 7 36 LEDs Illuminator side extended positioning with Pivot Fix Bracket Position 4 Figure 8 36 LEDs Illuminator compact positioning with Pivot Fix Bracket When...

Страница 28: ...t Impact VPM and connect to the camera 4 Direct the camera toward a correctly lighted calibration image or other clearly defined object 5 Select the Settings tab then click the Camera system object 6...

Страница 29: ...s camera and all the parts supplied with the equipment are present and intact when opening the packaging the list of parts includes 1 P2x Series camera base spacer camera 2 Quick Reference Guide 3 Mou...

Страница 30: ...s M4 x 6 on the body of the camera are for mounting the heatsink to the camera and this latter to the provided brackets The diagram below gives the overall dimensions of the camera and may be used for...

Страница 31: ...MECHANICAL DIMENSIONS PRODUCT REFERENCE GUIDE 23 Figure 3 Overall Dimensions with Connector at 90 mm in...

Страница 32: ...INSTALLATION 24 P2X SERIES Figure 4 STD Fix Bracket Overall Dimensions SLOTS SLO TS...

Страница 33: ...RODUCT REFERENCE GUIDE 25 P2x Series 36 LEDs ILLUMINATOR The P2x Series cameras 36 LEDs can be mounted horizontally and vertically Figure 5 Overall Dimensions with Connector at 0 mm in Connector block...

Страница 34: ...INSTALLATION 26 P2X SERIES Figure 6 Overall Dimensions with Connector at 90...

Страница 35: ...MECHANICAL DIMENSIONS PRODUCT REFERENCE GUIDE 27 Figure 7 Pivot Fix Bracket for 36 LEDs Illuminator large BK 32 010...

Страница 36: ...INSTALLATION 28 P2X SERIES Figure 8 Pivot Fix Bracket for 36 LEDs Illuminator small BK 32 010...

Страница 37: ...the diagram below Figure 11 14 LEDs Illuminator with STD Fix Bracket connectors at 0 and 90 NOTE The position of the device can be monitored The device alerts the user in case of orientation changes...

Страница 38: ...Ds Illuminator with STD Fix Bracket Figure 13 36 LEDs Illuminator side positioning with Pivot Fix Bracket connectors at 0 and 90 Figure 14 36 LEDs Illuminator front extended positioning with Pivot Fix...

Страница 39: ...Standard M12 X Coded female connector is provided for the on board Gigabit Ether net connection This interface is IEEE 802 3 10 BaseT and IEEE 802 3u 100 BaseTx com pliant Figure 1 M 12 X Coded Femal...

Страница 40: ...e overall maximum cable length must be less than 15 m 49 2 ft The following table contains the pinout for standard RS232 Serial interface RS485 Full Duplex Interface The Impact software does not suppo...

Страница 41: ...NCTION 1 Red 9 13 Vdc Power Supply Input voltage 2 Blk 7 25 GND Power Supply Input voltage Connector Case 1 Shield CHASSIS Connector case electrical connection to chassis 6 Org 5 Grn Blk 18 19 I1A Ext...

Страница 42: ...they offer the advantages of easy connection easy device replacement opto iso lated outputs Outputs 1 and 2 and filtered reference signals The outputs are programmed using VPM 1 Start VPM 2 Select the...

Страница 43: ...arity sensitive O2 Output 2 opto isolated and polarity sensitive CBX500 O3A Strobe Output 3 Single pin connection CBX500 O3B Not Used CBX800 O3A Strobe Output 3 Opto isolated See Note CBX800 O3B Strob...

Страница 44: ...eatures of both inputs are VAB 30 Vdc max IIN 10 mA camera 12 mA CBX max The active state of these inputs are selected in software Refer to the Camera Setup tab and Discrete Input tool sections of the...

Страница 45: ...igger Using P2x Series Power Figure 4 NPN External Trigger Using P2x Series Power CAUTION Power from the Vdc GND spring clamps is available directly to the Input Device on the V V spring clamps and do...

Страница 46: ...IONS USING EXTERNAL POWER Figure 5 PNP External Trigger Using External Power Figure 6 NPN External Trigger Using External Power CBX500 800 FUNCTION V Power Source Inputs I2A Input 2 or polarity insens...

Страница 47: ...ing P2x Series Power Figure 8 NPN Input 2 Using P2x Series Power CAUTION Power from the Vdc GND spring clamps is available directly to the Input Device on the V V spring clamps and does not pass throu...

Страница 48: ...xternal Power Figure 10 NPN Input 2 Using External Power OUTPUTS The outputs are programmed using VPM 1 Start VPM 2 Select the General icon 3 Select the Communication button NOTE When Outputs 1 and 2...

Страница 49: ...sensitive O2 Output 2 opto isolated and polarity sensitive O2 Output 2 opto isolated and polarity sensitive CBX500 03A Strobe Output 3 Single pin connection CBX500 03B Not used CBX800 O3A Strobe Outp...

Страница 50: ...tor Output Using P2x Series Power OUTPUT 1 AND 2 CONNECTIONS USING EXTERNAL POWER Figure 13 PNP Output Open Emitter Using External Power NOTE Power from the Vdc GND spring clamps is available directly...

Страница 51: ...nts By default it is not assigned to any event The CBX500 or CBX800 must be used to connect this output OUTPUT 3 CONNECTIONS USING P2x Series POWER CBX500 Only Figure 15 Output 3 Using P2x Series Powe...

Страница 52: ...non opto isolated but short circuit protected outputs are avail able on the M12 17 pin connector The pinout is the following The electrical features of the three outputs are the following Reverse Pola...

Страница 53: ...9 PNP Output Connection Figure 20 NPN Output Connection CAUTION For NPN output connections the external interface voltage Vext must not exceed the P2x Series power supply source voltage Vdc otherwise...

Страница 54: ...nd Windows 10 Microsoft Windows 7 Windows 8 1 or Windows 10 4 GB or more of RAM 8 GB recommended 2 GB or more of available hard disk space 1Gbps 1000Mbps Ethernet connection Monitor display resolution...

Страница 55: ...button The firm ware update dialog will appear Package is automatically selected and loaded 5 When the connection is complete click the Settings tab 6 Click the camera icon click the Setup tab then c...

Страница 56: ...t of time the shutter is open The higher the number the longer the shutter is open and the brighter the image The Mode type affects the Shutter range limits Under exposure To correct this result it is...

Страница 57: ...rnal Illuminator mounted on the camera and the number of Lighting Chains that the Illuminator contains LIGHTING CHAINS Chains Enabled for the 14 LEDs Illuminator Peripheral The eight LEDs around the e...

Страница 58: ...or Chain 1 Chain 2 Chain 3 Chain 4 Chain 5 Chain 6 The pictures below display the relative position on the illuminator Illuminator Vertical Position Chain 4 Chain 5 Chain 6 Chain 1 Chain 3 Chain 2 Ill...

Страница 59: ...ARTIAL SCAN In order to satisfy very high throughput applications higher frame rates can be achieved using the powerful Partial Scan parameters in the Camera setup menu Partial Scan allows defining a...

Страница 60: ...use an inter nal illuminator and another setting could enable and use an external lighting system The P2x Series offers two Illuminators options 14 or 36 LEDs and standard or polarized cover to remov...

Страница 61: ...lecting surfaces DPM on electronic circuit boards Glossy labels Labels under plastic films By removing LED reflection P2x Series with polarized illuminators features extreme mounting flexibility as it...

Страница 62: ...ue is commonly used for parts presence absence gauging and orientation location The light is oriented behind a transparent object of interest to examine surface features Bright Field Illumination Ligh...

Страница 63: ...lly this type of lighting is used in solutions to enhance reflectance of the uneven surface It is also used with very reflective surfaces Structured Field Illumination The light is projected with a kn...

Страница 64: ...the Impact Reference Guide If you re unable to fix the problem and you re going to contact your local Datalogic office or Datalogic Partner we suggest providing if possible software version Serial Num...

Страница 65: ...king correctly Is the sensor reflector system aligned if present In VPM check the Debounce settings Settings General Communication Is the camera online Communication camera is not transmit ting anythi...

Страница 66: ...NPN or PNP short circuit protected configure in VPM Camera Setup Opto isolated only when connected to CBX500 800 Output 3 NPN or PNP short circuit protected configure in VPM Camera Setup Opto isolate...

Страница 67: ...ILLUMINATOR Dimensions with lens cover H x W x L 109 x 54 x 56 mm 4 3 x 2 1 x 2 2 in H x W x L 116 x 126x70 mm 4 6 x 4 9 x 2 8 in Weight about 380g 13 4 oz about 640g 22 5 oz Material Aluminium USER...

Страница 68: ...TECHNICAL FEATURES 60 P2X SERIES Optical sensor response...

Страница 69: ...e boundary eight adjacent binary digits 0 and 1 combined in a pat tern to represent a specific character or numeric value Bits are numbered from the right 0 through 7 with bit 0 the low order bit One...

Страница 70: ...as net work control database access special programs supervisory programs or program ming languages IMAGE PROCESSING Any form of information processing for which the input is an image and the output...

Страница 71: ...s a wide range of OCR tools for more information see Impact Reference Guide PATTERN RECOGNITION The automated recognition process of patterns and regularities in data The information stored in a datab...

Страница 72: ...t no part of this documentation may be reproduced stored in or introduced into a retrieval system or transmitted in any form or by any means or for any purpose without the express written permission o...

Отзывы: