background image

SUPPORT THROUGH THE WEBSITE

Datasensing provides several services as well as technical support through its 
website. 
Log on to 

www.datasensing.com

.

For quick access, from the home page click on the search icon , and type in the 
name of the product you’re looking for. This allows you access to download Data 
Sheets, Manuals, Software & Utilities, and Drawings.

PATENT

See www.patents.datalogic.com for patent list.
This product is covered by one or more of the following patents:
Utility patents: EP2517148B1, EP2649555B1, EP2946338B1

,

 US10095951, 

US10552699, US10762405, US8888003, US8915443, US9396404, 
US9495607, US9798948, ZL200980163411.X, ZL201080071124.9

SEALS

The Industrial Vision Processor has seals in some areas. The seals must not 
be broken or removed for any reason. The sealed parts may be opened only 
and exclusively by Datasensing. Breakage of these seals by a customer shall 
result in immediate cancellation of the warranty on the entire Industrial Vision 
Processor.

ELECTRICAL FEATURES

Supply voltage (Vs)

9 ~ 36VDC

Current Consumption

Nominal: 5.5 A at 24VDC
Maximum: 23A  at 9VDC; 6A at 36VDC 

Digital  Inputs

16 opto-isolated, see Digital I/O Speci

fi

 cations. 

Input Voltage

Logic 0: 3V max
Logic 1: 10V min (30V max) or dry contact.

Input Resistance

3.21k

Ω

On Current

>3mA

O

  Current

<1mA

Current Maximum

8.5 mA @30VDC

Isolation Protection

2500VDC

Optical isolation response 
time

100

μ

sec 

Overvoltage protection

70VDC

Load Voltage

5 ~ 40VDC

Load Current

350mA (max per channel)

Input current

3.28mA @ 12VDC
6.71mA @24VDC

Digital Outputs

16 opto-isolated (con

fi

 gurable sink-NPN or 

source-PNP), see Digital I/O Speci

fi

 cations. 

Format

Opto-coupler isolated open emitter output

Residual Voltage Output On

2V or less (output current 

mA)

Optical isolation response 
time

100

μ

sec

Camera interface

GigE  (up to 8 depending on model)

USB Hardware Port

USB 2.0 Port for USB Hardware Key

USB Ports

8x USB 3.0 ports for monitor, mouse and 
keyboard 

Graphic Interface

Intel® HD (1920x1200 resolution) VGA, DVI

Host Communications: 

Serial Communications

2x RS-232 Serial Port (COM 1 + COM 2)

Ethernet

10/100/1000 Mbps Ethernet x 2
Ethernet/RIP, Modbus, TCP, OPC, PROFINET 
communications supported.

PHYSICAL FEATURES

Dimensions

7.55 w x 5.74 h x 9.05 d (in)
192 w x 145 h x 230 d (mm)

Weight

4450 g

Housing material

Metal

ENVIRONMENTAL FEATURES

Temperature

Operating: 0° to +50° C (+32° to +122° F)
Storage: -20° to +70° C (-4° to +158° F)

Relative Humidity 

5 to 95%, non condensing 

Vibrations
(EN60068-2-64)

Random: 5 to 500Hz 3g

Vibrations
(EN60068-2-6)

Sine: Ramp to 2g from 5 to 15Hz
15 to 500Hz 2g

Shock resistance
(EN60068-2-27)

Half sine: 11ms (50g Max) 

Mechanical protection 
(EN 60529)

IP20

SOFTWARE FEATURES

Minimum Impact Software 
Version Required

12.2.0

HARDWARE FEATURES

CPU

Intel® Core i7

System Memory 

DDR4 RAM 32GB.

Storage

128 GB SSD, 1 CFast slot. 

TECHNICAL DATA

821005994 

Rev. E 

May 2022

CHINA ROHS TABLE OF RESTRICTED ELEMENTS

EXTRA DIGITAL OUTPUT GROUNDING

The spring clamp connector on the I/O Card provides two extra connections that 
are equivalent to the GND/PCOM pin on the 37-pin connector and are used to 
increase the current tolerance on the I/O Card. The spring clamp pins should 
be connected whenever the combined total output current is higher than 3.2A.

The pin assignments are as follows: 
Pin 1: PCOM, used in source type (PNP) connections
Pin 2: GND, used in sink type (NPN) connections

Spring Clamp Connector Pin De

fi

 nition

Cable

Part Number

Digital I/O 37-pin  to Terminal Block 248-0110

606-0675-xx

Digital I/O 37-pin to pigtail (remove one end)

606-0675-xx

Note: 

Do not disconnect the cable at the connector while power is on. 

WARRANTY

The warranty period for this product is 24 months. See General Terms and 
Conditions of Sales at www.datasensing.com for further details. 

CE COMPLIANCE

EUROPEAN DECLARATION OF CONFORMITY

Hereby, Datasensing S.r.l. declares that the full text of the European Declaration 
of Conformity is available at: www.datasensing.com. Select the link from the 
downloads section of the product page.

UKCA DECLARATION OF CONFORMITY

Hereby, Datasensing S.r.l. declares that the full text of the UKCA Declaration 
of Conformity is available at: www.datasensing.com. Select the link from the 
downloads section of the product page.

WARNING

This is a Class A product. In a domestic environment this product may cause 
radio interference in which case the user may be required to take adequate 
measures.

FCC COMPLIANCE

Modi

fi

 cations or changes to this equipment without the expressed written 

approval of Datasensing could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to 
the following two conditions: (1) This device may not cause harmful interference, 
and (2) this device must accept any interference received, including interference 
which may cause undesired operation.

This equipment has been tested and found to comply with the limits for a 
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are 
designed to provide reasonable protection against harmful interference when the 
equipment is operated in a commercial environment. This equipment generates, 
uses, and can radiate radio frequency energy and, if not installed and used in 
accordance with the instruction manual, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area is likely to 
cause harmful interference in which case the user will be required to correct the 
interference at his own expense.

EAC COMPLIANCE

Customs Union:
The CU Conformity certi

fi

 cation has been achieved; this allows the Product to 

bear the Eurasian mark of conformity.

LEGAL NOTICES

©2021-2022 DATASENSING S.R.L. 

• All rights reserved • Without limiting the rights under copyright, no part of 
this documentation may be reproduced, stored in or introduced into a retrieval 
system, or transmitted in any form or by any means, or for any purpose, without 
the express written permission of Datasensing S.r.l. 

DISCLAIMER

Datasensing has taken reasonable measures to provide information in this 
manual that is complete and accurate, however, Datasensing shall not be liable 
for technical or editorial errors or omissions contained herein, nor for incidental 
or consequential damages resulting from the use of this material. Datasensing 
reserves the right to change any speci

fi

 cation at any time without prior notice.

TRADEMARKS

Datasensing and the Datasensing logo are trademarks of Datasensing S.r.l.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. 
in many countries, including the U.S. and the E.U. Impact is a trademark of 
Datasensing S.r.l. and/or its a

  liates, registered in many countries, including the 

U.S. and the E.U. MX-E Series, Vision Program Manager (VPM) are trademarks 
of Datasensing S.r.l. and/or its a

  liates. All other trademarks and brands are 

property of their respective owners.  

MX-E90

䜘Ԧ਽〠

᭷ẘ᭷ᐖ

ᡈඖ⣲

PART

Lead

(Pb

)

Mercury 

(Hg)

Cadmium 

(Cd)

භ௴

Hexavalent 

Chromium (

C

r(VI

)

㹜俼劗

Polybrominated biphen

yl

(PBB)

㹜Ḵ劗

Polybrominated diphen

yl

 

ethers (PBDE)

Metal Parts

䠁኎䜘Ԧ

X

O

O

O

O

O

Panel (if an

y)

䶒ᶯ

(

ྲᴹ

)

X

O

O

O

O

O

ᵜ㺘Ṭ׍ᦞ

6-7

Ⲵ㿴ᇊ㕆ࡦDŽ

ƻ

㺘⽪䈕ᴹᇣ⢙䍘൘䈕䜘Ԧᡰᴹ൷䍘ᶀᯉѝⲴਜ਼䟿൷൘

*%7

㿴ᇊⲴ䲀䟿㾱≲ԕлDŽ

h

㺘⽪䈕ᴹᇣ⢙䍘㠣ቁ൘䈕䜘ԦⲴḀа൷䍘ᶀᯉѝⲴਜ਼䟿䎵ࠪ

*%7

㿴ᇊⲴ䲀䟿㾱≲DŽ

I/O CONFIGURATION

Camera communication uses Cat6 Ethernet cable and provides POE for M1xx 
and E1xx cameras. Use only Datasensing provided cables.

COMMUNICATIONS

Vision Program Manager (VPM) software installed on the processor is used to 
create vision programs and con

fi

 gure input and output response. Refer to the 

Impact Reference Guide for programming details.

DIGITAL I/O CABLES TERMINALS AND CONNECTIONS

Datasensing S.r.l.

Strada S. Caterina 235

41122 Modena

Italy

Tel. +39 059 420411

Fax +39 059 253973

Содержание MX-E90

Страница 1: ...y Minus Chassis Grounding Connect to ground using a conductor with minimum 2 5 mm cross section Power 24 Supplied Power DIGITAL I O SPECIFICATIONS Pin Color Code Signal Name 1 Black Input 1 2 Brown Input 3 3 Red Input 5 4 Orange Input 7 5 Yellow Input 9 6 Green Input 11 7 Blue Input 13 8 Purple Input 15 9 Gray Common pin for external source or ground of Input 1 to Input 16 10 White PCOM0 NPN commo...

Страница 2: ... EUROPEAN DECLARATION OF CONFORMITY Hereby Datasensing S r l declares that the full text of the European Declaration of Conformity is available at www datasensing com Select the link from the downloads section of the product page UKCA DECLARATION OF CONFORMITY Hereby Datasensing S r l declares that the full text of the UKCA Declaration of Conformity is available at www datasensing com Select the l...

Страница 3: ...2 棕色 输入3 3 红色 输入5 4 橙色 输入7 5 黄色 输入9 6 绿色 输入11 7 蓝色 输入13 8 紫色 输入15 9 灰色 输入 1 至输入 16 的外部源或接地的公共引脚 10 白 PCOM0 NPN 用于连接 O 1 至 O 8 的感性负载的公共引脚 NPN O 1 至 O 8 的外部电压的公共引脚 11 粉色 输出1 12 浅绿色 输出3 13 黑色 白色 输出5 14 棕色 白色 输出7 15 红色 白色 输出9 16 橙色 白色 输出11 17 绿色 白色 输出13 18 蓝色 白色 输出15 19 紫色 白色 PCOM1 NPN 用于连接 O 9 至 O 16 的感性负载的公共 引脚 NPN O 9 至 O 16 的外部电压的公共引脚 20 红色 黑色 输入2 21 橙色 黑色 输入4 22 黄色 黑色 输入6 23 绿色 黑色 输入8 24 灰色 黑色 输入...

Страница 4: ...xx 注意 切勿在电源通电时连接电缆 安装在处理器上的 Vision Program Manager VPM 软件用于创建视觉程序并 配置输入和输出响应 请参阅影响参考指南获取编程细节 通信 摄像头通信使用 Cat6 以太网电缆 为 M1xx 和 E1xx 摄像头提供 POE 请仅使 用 Datasensing 提供的电缆 I O 配置 CE 符合性 欧洲符合性声明 在此 Datasensing S r l 声明欧洲符合性声明的全文可在以下网址获得 www datasensing com 从产品页面的下载部分选择链接 UKCA 符合性声明 在此 Datasensing S r l 声明 UKCA 符合性声明的全文可在以下网址获 得 www datasensing com 从产品页面的下载部分选择链接 报警 本产品属于 A 类产品 本产品在室内环境中可能造成无线电干扰 在这种情况 下 用户可...

Отзывы: