![Datalogic Magellan 9500 Omega Скачать руководство пользователя страница 314](http://html1.mh-extra.com/html/datalogic/magellan-9500-omega/magellan-9500-omega_product-reference-manual_512135314.webp)
6-198
Magellan
®
9500
Code 39 Length Control
This feature specifies whether variable-length or fixed-length decoding
will be set for Code 39.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan your selection from the bar codes below. You’ll need to cover
any unused bar codes on this and the facing page to ensure that the
scanner reads only the bar code you intend to scan.
3. Complete the programming sequence by scanning the SWITCH
bar code.
CODE 39 LENGTH CONTROL = VARIABLE-LENGTH
CODE 39 LENGTH CONTROL = FIXED-LENGTH
NOTE
If variable-length control was selected, you must now set the features
Code
39 Maximum Label Length
and
Code 39 Minimum Label Length
. If fixed-
length control was selected, you must now set
Code 39 Fixed Length 1
and
Code 39 Fixed Length 2
.
When using variable length stitching, it is important to enable
Code 39 Check
Character Calculation
to prevent misreads.
Содержание Magellan 9500 Omega
Страница 1: ...Magellan 9500 9500 9504 9504 with SmartSentry Product Reference Guide...
Страница 28: ...1 16 Magellan 9500 NOTES...
Страница 86: ...3 16 Magellan 9500 Figure 3 5 Removing Replacing the WRG Window Slide WRG Window Out Remove Vertical Bezel...
Страница 100: ...4 14 Magellan 9500 NOTES...
Страница 116: ...5 16 Magellan 9500 NOTES...
Страница 396: ...6 280 Magellan 9500 NOTES...
Страница 416: ...B 10 Magellan 9500 NOTES...
Страница 426: ...D 2 Magellan 9500 NOTES...
Страница 442: ...E 16 Magellan 9500 NOTES...
Страница 458: ...F 16 Magellan 9500 NOTES...