OTHER CONTROLS
Code
Parameter
Description
I.D.#
Accept.
Input
Defaults
Scanner
Type
Mi
n
Max
Factory
Laser
2D Image
r
Lor
ax
Enter 1 for On and 0 for Off
Enable Label
Programming
Enables/disables
the ability to
perform label
programming.
FF00
On or Off
On
On
On
√
√
√
Send
Symbology
Identifiers
Specifies the
symbology identifier
(if any) that is sent by
the decoder when
parameter Send Code
ID (Index 0025) is set
to 3. ASCII code zero
(null) used to indicate
an identifier not to be
sent for the
symbology.
0025
Select
symbology
identifier to
transmit
immediately
preceding
scanned
data:
0=None
1=DLM
identifier
before label:
<ID> " "
<data>
2=AIM
identifier
before label:
"]" <ID>
<modifier>
<data>
3=User
defined
identifier
before label:
<ID> <data>
4=DLM
identifier
after label:
<data> " "
<ID>
5=AIM
identifier
after label:
<data> "]"
<ID>
<modifier>
6=User
defined
identifier
after label:
<data> <ID>
00 01 00
√
√
√
Содержание Lynx 00N0LD-1N0-MEN0
Страница 28: ...NOTE ...
Страница 39: ...Remove the protective film cover over the Laser Output Window before use NOTE ...
Страница 43: ...Numeric Keyboard ...
Страница 131: ...Code 128 ÌtestwÎ test 120 EAN 13 x 0B2DE5 KKKKLM 120 EAN 8 6450 TRMN ...
Страница 132: ...2D Codes Datamatrix ECC200 Example Inverse Datamatrix ECC200 Example ...
Страница 175: ...6 technology that permits communication within about 10 meters in other words a very short range ...
Страница 185: ...T Data Capture Laser Output Window U Handylink Connector host slave ...
Страница 188: ......