Datalogic LT-700 Скачать руководство пользователя страница 2

LT-700 POSITIONING FOR MATRIX 210™ STRAIGHT MODELS 

 

 

LT-700 30° Illumination Angle 

 

 

LT-700 45° Illumination Angle 

 

 

LT-700 60° Illumination Angle 

 

NOTE

 

The positioning drawings, intended to show the various 
adjustments, are graphically representative of the Matrx 210™ 
Medium model and are significantly different for other models. 

 

Matrix 210™ + LT-700 Positioning Reference Table 

Straight 

Models 

Focus 

Distance 

Clearance Illumination 

Angle 

 

 

 

 

 

A B 

Near 

45 

(1.8) 

43.5 

(1.7) 

30° 

33 (1.3)  66 (2.6) 

45° 

82 (3.2)  66 (2.6) 

60° - - 

Medium 

65 

(2.6) 

55 

(2.2) 

30° 

19 (0.7)  75 (3.0) 

45° 

72 (2.8)  75 (3.0) 

60° 

97 (3.8)  75 (3.0) 

Far 

105 

(4.1) 

55 

(2.2) 

30° 

7 (0.3)  75 (3.0) 

45° 

53 (2.1)  75 (3.0) 

60° 

75 (3.0)  75 (3.0) 

 

1.  Position and mount the Matrix assembly over the code reading 

area at the correct Focus Distance 

M

 for your model. 

2.  Using the positioning diagrams and the LT-700 Positioning 

Reference Table, you can obtain the given illumination angles at 
the given code clearance by adjusting the LT-700 bracket 
assembly as follows: 

Set measurement 

A

 according to the LT-700 Positioning 

Reference Table and tighten the LT-700 sliding bracket screws. 

Set measurement 

B

 according to the LT-700 Positioning 

Reference Table and tighten the rotating bracket screws. 

3.  Rotate the LT-700 angle 

 to the indicated Illumination Angle; the 

lower corner of the LT-700 matches the Clearance value. Tighten 
the LT-700 positioning screws. 

4.  Run the VisiSet™ configuration program and follow the Setup 

Wizard and Data Matrix Setup Wizard procedures in VisiSet™ to 
complete installation. 

 

 

NOTE

 

The values given for LT-700 

positioning

 are based on three 

common angles for DPM applications and demonstrate the 
basic positioning procedure. Your application may require 
different settings. 

 

 

NOTE

 

By reducing 

clearance

, LT-700 can be positioned closer to 

the code surface to maximize illumination. 
If necessary, 

clearance

 can be increased with some reduction 

in lighting power on the code surface. 

 

TECHNICAL FEATURES 

 

Supply Voltage 

10 to 30 Vdc 

Power Consumption 

0.25 to 1.0 A; 3 W max. 

Optimal Working Distance 

application dependent 

Effective Working Range 

application dependent 

Illumination Area: 

 

@ 50 mm (2 in) 

70 × 55 mm (2.75 × 2.16 in) 

@ 75 mm (3 in) 

80 × 70 mm (3.15 × 2.75 in) 

@ 100 mm (4 in) 

90 × 85 mm (3.54 × 3.35 in) 

Wavelength 630 

nm 

Typical Irradiance 

180 W/m² @ 75 mm 

(with Exposure Time 

 500 

s) 

Operating Temperature 

0 to 50 °C (32 to 122 °F) 

Storage Temperature 

-20 to 70 °C (-4 to 158 °F) 

Max Humidity 

90% non-condensing 

Vibration Resistance 
EN 60068-2-6 

1.5 mm @ 5 to 9 Hz; 

0.5 g @ 9 to 150 Hz 

2 hours on each axis 

Shock Resistance 
EN 60068-2-27 

15g; 11 ms; 3 shocks on each axis 

Protection Class 
EN 60529 

IP65 

Dimensions (L x H x W) 
(without bracket) 

68 x 33 x 28 mm (2.7 x 1.3 x 1.1 in) 

Weight (without bracket) 

113 g. ( 4 oz.) 

 
 

COMPLIANCE 

 

LED Safety 

LED EMISSION ACCORDING TO EN 62471 
 

FCC Compliance 

Modifications or changes to this equipment without the expressed written approval of Datalogic 
could void the authority to use the equipment. 

 

This device complies with PART 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any 
interference received, including interference which may cause undesired operation. 

 

This equipment has been tested and found to comply with the limits for a Class A digital device, 
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference when the equipment is operated in a commercial environment. This 
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 
accordance with the instruction manual, may cause harmful interference to radio communications. 
Operation of this equipment in a residential area is likely to cause harmful interference in which case 
the user will be required to correct the interference at his own expense. 
 

EAC Compliance 

Customs Union: 
The CU Conformity certification has been achieved; this allows the Product to bear the 
Eurasian mark of conformity. 

 

Datalogic S.r.l. 

Via S. Vitalino 13 - 40012 Calderara di Reno - Italy 
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com

 

 
© 2012 - 2017 Datalogic S.p.A. and/or its affiliates 

 ALL RIGHTS RESERVED. 

 Without limiting the 

rights under copyright, no part of this documentation may be reproduced, stored in or introduced into a 
retrieval system, or transmitted in any form or by any means, or for any purpose, without the express 
written permission of Datalogic S.p.A. and/or its affiliates. Datalogic and the Datalogic logo are 
registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other 
trademarks and brands are property of their respective owners. Datalogic reserves the right to make 
modifications and improvements without prior notification. 
 

821002302 (Rev. B) 





