SIGNAL TABLES

Description

LED

Connection symbol Battery symbol

Audio signal

Vibration

Barcode data could be 

transferred

Short green 

flashing

Short positive 

beep

Short vibration

Barcode data could not be 

transferred

Red flashing 3 

times briefly

Long negative 

beep

Long vibration

Battery charge under 10%

Slow red flashing

Battery charge under 7%

Red flashing 3 

times briefly

Switch on HandScanner 

with battery charge under 

5%

Red flashing 3 

times briefly

Battery charge under 95%

Pulsating red

Battery charge over 95%

Constantly green

General HandScanner

HandScanner Connection via BLE

Description

LED

Connection symbol Battery symbol

Audio signal

Vibration

HandScanner searches 

for an end device

Blue pulsating

Blue pulsating

Continuously 

rising beep

HandScanner is con-

nected to an end device

Blue flashing 2 

times briefly

Blue flashing 2 times 

briefly

Short rising 

positive beep

Short vibration

HandScanner cannot con-

nect to the end device

Red flashing 3 

times briefly

Negative beep 

briefly 3 times

Long vibration

HandScanner is discon-

nected from the end 

device

Red flashing 3 

times briefly

Negative beep 

briefly 3 times

Long vibration

Gateway

Description

LED 1 (USB - LED)

LED 2 (Scanner - LED)

LED 3 (Cloud - LED)

Gateway boots up

1

 

Left to right run through all LEDs alternating Blue / Green until start

Gateway is connected to the 

end device via USB

Constantly green

Gateway is not connected to 

the end device via USB

No feedback

Gateway searches for a 

HandScanner

Pulsing blue

Gateway is connected to the 

HandScanner via BLE

Constantly green

Firmware Update: Gateway is 

in dowload mode

Constantly yellow

Constantly yellow

Constantly yellow

Firmware Update: Hand-

Scanner is flashing / Gateway 

deploys

Constantly purple

Constantly purple

Constantly purple

Firmware Update: Gateway is 

flashing

left to right run through all LEDs alternating purple until done

Firmware Update: successful

Long green flashing

Long green flashing

Long green flashing

Gateway is connected to a 

HandScanner and is searching 

for more HandScanners

Constantly green

Gateway cannot connect to 

another HandScanner

Constantly red

Gateway cannot connect to 

another HandScanner but 

another HandScanner is trying 

to connect

Red flahsing 3 times briefly

1  It take approx. 2 minutes to boot up.

Содержание HS7500

Страница 1: ...ty Datalogic warrants that the Products shall be free from defects in materials and workmanship under normal and proper use during the Warranty Period Products are sold on the basis of specifications...

Страница 2: ...OF HANDSCANNER SYSTEM 10 1st Step Charge HandScanner 10 2nd Step Connect the Gateway 10 3rd Step Switch on the HandScanner 11 4th Step Connect the HandScanner 11 4th Step Connect the HandScanner BLE...

Страница 3: ...2 TROUBLESHOOTING 22 HandScanner 22 BLE Data Transfer 23 Gateway 23 Gateway Data Transfer 23 Charging Station 23 DISPOSAL 23 DIRECTIVES CERTIFICATION 24 European Directives 24 Declaration of Conformit...

Страница 4: ...ION Keep all cables and wires away from high voltage sources This may otherwise lead to damage or faults due to overvoltage line noise electrostatic discharge or other irregularities Hardware CAUTION...

Страница 5: ...s Check whether Hardware and Wearables are properly packaged and undamaged HandScanner Standard range Mid range Wearables Hand Trigger Connectivity device Datalogic Gateway with USB cable Charging sta...

Страница 6: ...iminates all standard 1D codes including GS1 DataBar linear codes 2D PDF417 MicroPDF417 Data Matrix QR Code Micro QR Code Aztec MaxiCode Postal US PostNet US Planet UK Postal Australia Postal Japan Po...

Страница 7: ...pairing is possible The Gateway can be connected with up to 5 HandScanners simultaneously See Con nection with USB cable in USB CDC mode on page 10 Gateway Pairing Barcode LED 1 UBS LED LED 2 Scanner...

Страница 8: ...r The Charging Station can be attached to work stations for example through the attachment openings with M5 screws or cable ties Charging Station Attachment opening for M5 screws Charging tray Attachm...

Страница 9: ...y after use Hand Trigger Textile trigger Label with size indication Hand Trigger Properties General Packaging unit 10 pieces per package Available sizes S M L Materials Nylon Polyester MDF EVAC glue S...

Страница 10: ...Connect the USB cable with the end device 2 Plug the other end of the USB cable into the Micro USB socket of the Gateway A clear clicking sound confirms the correct fastening RESULT The LED of the Gat...

Страница 11: ...BLE HID to an end device Possible operating systems are Apple iOS Google Android Microsoft Windows The individual steps for connecting to the respective operating systems for the first time can be fo...

Страница 12: ...will flash blue twice and you will hear two beeps The HandScanner will be shown as connected under My devices and is ready for use 01 02 03 RESULT DLHS 00000 Under Settings Connected devices switch o...

Страница 13: ...d is ready for use 04 Click Done DLHS 00000 DLHS 00000 5th Step Scan CAUTION For mid range scanning range do not look directly into the crosshairs Otherwise this can lead to temporary blinding effects...

Страница 14: ...smitted it to the end device 6th Step Disconnect HandScanner Disconnect HandScanner from the Gateway Place HandScanner in the Charging Station RESULT HandScanner is disconnected from the Gateway and c...

Страница 15: ...Device The HandScanner will flash red three times and you will hear three beeps HandScanner will no longer be shown as connected under My devices DLHS 00000 DLHS 00000 Disconnect from Google Android...

Страница 16: ...HandScanner will no longer be shown as connected under Bluetooth other devices DLHS 00000 DLHS 00000 7th Step Release HandScanner from Wearable CAUTION Do not rub over the pins of the wearable with th...

Страница 17: ...1st Step Opening Configurations 1 Go to Configurations in the Insight navigation 2 Select a saved configuration or create a new one NOTE To install a saved configuration proceed with 7th Step Configu...

Страница 18: ...Insight Mobile or the Gateway For a firmware update y To upgrade the HandScanner firmware download the latest version of Insight Mobile App from https www data logic com handscanner config Download s...

Страница 19: ...tant green light 2 Scan the Pairing Barcode on the Gateway 3 Scan this barcode to enable the Gateway as a mass storage device on the computer 4 Copy the downloaded configuration file or the firmware f...

Страница 20: ...anner is discon nected from the end device Red flashing 3 times briefly Negative beep briefly 3 times Long vibration Gateway Description LED 1 USB LED LED 2 Scanner LED LED 3 Cloud LED Gateway boots u...

Страница 21: ...OK Not applicable OK OK Memor 10 OK Not applicable OK OK Memor 20 OK Not applicable OK OK Rhino II Android OK OK OK Not compatible Rhino II Windows Embedded Compact 7 Not compatible OK Not compatible...

Страница 22: ...e wearables are meant to be replaced periodically due to normal wear and tear This is because gloves and wraps contain sensitive electronics in and around the scan trigger With care it is possible to...

Страница 23: ...lowing steps to decommission HandScanner system 1 Release HandScanner from Wearables 2 Disconnect the connection cable from the Acess Point Gateway 3 Disconnect the mains plug from the Charging Statio...

Страница 24: ...S 2015 863 EU Declaration of Conformity Datalogic S r l hereby declares that the devices are in compliance with all applicable Directives For the full text of the CE Declaration of Conformity please c...

Страница 25: ...25 APPENDIX CONFIGURATION BARCODES Pairing Barcode Gateway Mass Storage ON Gateway Mass Storage OFF Scanner Factory Reset Gateway Factory Reset...

Отзывы: