Reading Parameters
Product Reference Guide
293
Reading Parameters
Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains
on following a good read. The good read LED on time can be set within a
range of 10 milliseconds to 2,550 milliseconds (0.001 to 2.55 seconds) in
100ms increments.
Follow these instructions to set this feature:
1. Determine the desired setting in milliseconds. A setting of 0 means that
the good read LED stays on until the next time the trigger is pulled.
2. Divide the desired setting by 10 (setting is in 100ms increments). Pad
the result with leading zeroes to yield three digits. For example: 0 =
000, 5 = 000, 20 = 020, etc.
3. Go to
and scan the ENTER/EXIT PROGRAMMING MODE bar
code to enter Programming Mode.
4. Scan the bar code: SELECT GOOD READ LED DURATION SETTING.
5. Scan the appropriate three digits from the keypad in
representing the duration which was determined in the steps
above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
ming Mode.
This completes the procedure. See
for some examples of how to
set this feature.
Table 37. Good Read LED Duration Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
Good Read LED
stays on until
next trigger pull
(00)
20ms
150ms
2550ms (2.55 sec.)
2
Divide by 10 (and pad with
leading zeroes)
000
002
015
255
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT GOOD READ LED DURATION SETTING
5
Scan Three Characters From
‘0’, ‘0’ and ‘0’
‘0’, ‘0’ and ‘2’
‘0’, ‘1’ and ‘5’
‘2’, ‘5’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE
Содержание Gryphon I GD4400
Страница 40: ...Setup 38 Gryphon I GD44XX GBT4400 GM440X NOTES...
Страница 44: ...Enter Exit Programming Mode 42 Gryphon I GD44XX GBT4400 GM440X NOTES...
Страница 58: ...Enter Exit Programming Mode 56 Gryphon I GD44XX GBT4400 GM440X NOTES...
Страница 68: ...Enter Exit Programming Mode 66 Gryphon I GD44XX GBT4400 GM440X NOTES...
Страница 78: ...Enter Exit Programming Mode 76 Gryphon I GD44XX GBT4400 GM440X NOTES...
Страница 102: ...Enter Exit Programming Mode 100 Gryphon I GD44XX GBT4400 GM440X NOTES...
Страница 248: ...246 Gryphon I GD44XX GBT4400 GM440X NOTES...
Страница 308: ...References 306 Gryphon I GD44XX GBT4400 GM440X NOTES...
Страница 338: ...Keypad 336 Gryphon I GD44XX GBT4400 GM440X A B C D E F...
Страница 348: ...Scancode Tables 346 Gryphon I GD44XX GBT4400 GM440X NOTES...